Schneider A9F74101 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 1A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
Description
Schneider A9F74101 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 1A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
Product Overview: Schneider A9F74101 | Miniature Circuit Breaker (MCB) – Acti9 iC60N – 1P – 1A – C Curve – 6000A
The Schneider Electric A9F74101 is a Miniature Circuit Breaker (MCB) from the trusted Acti9 iC60N series. Designed for high-performance protection of electrical circuits, it features 1 pole (1P), a rated current of 1A, C curve tripping, and a breaking capacity of 6000A (IEC/EN 60898-1) and up to 50kA (IEC/EN 60947-2) in certain industrial settings.
Key Features:
-
Brand: Schneider Electric
-
Series: Acti9 iC60N
-
Model Number: A9F74101
-
Product Type: Miniature Circuit Breaker (MCB)
-
Poles: 1P (Single Pole)
-
Rated Current: 1 Ampere (1A)
-
Tripping Curve: C Curve
-
Breaking Capacity:
– 6 kA (IEC/EN 60898-1)
– Up to 50 kA (IEC/EN 60947-2 – industrial environments) -
Voltage Rating: 230/400 V AC
-
Frequency: 50/60 Hz
Technical Specifications:
-
Standard Compliance:
– IEC/EN 60898-1 (for residential and commercial applications)
– IEC/EN 60947-2 (for industrial-grade performance) -
Mounting Type: DIN Rail
-
Terminal Capacity: 1.5–25 mm²
-
IP Rating: IP20 (with insulation)
-
Mechanical Life: Up to 20,000 operations
-
Electrical Life: Up to 10,000 operations
Functional Features:
-
Reliable Overcurrent Protection:
– Protects circuits from overloads and short-circuits -
C Curve Tripping:
– Ideal for standard applications with moderate inrush currents (e.g., lighting, sockets, control circuits) -
Visual Trip Indicator:
– Clear status display for easy diagnosis -
Fast Connection System:
– Terminal clamps for fast and safe wiring -
Clip-On Mounting:
– Quick installation and removal
Applications:
-
Residential power distribution boards
-
Commercial and office buildings
-
Control panels and switchgear
-
Final distribution circuits
-
Circuits with resistive or lightly inductive loads
Benefits:
-
Compact and Efficient:
– Saves space and simplifies layout -
High Protection Level:
– Combines standard and industrial-grade breaking capacities -
Modular Design:
– Easily integrates with other Acti9 devices -
Durable Performance:
– Designed for long service life under repeated operations -
Safe and Certified:
– Complies with global standards for circuit protection
Typical Users:
-
Electrical engineers and contractors
-
Panel builders
-
Residential and commercial electricians
-
Facility management teams
-
System integrators and consultants
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | IC60N |
| Poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 1 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | EN 60898-1 EN 60947-2 IEC 60898-1 IEC 60947-2 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 50 kA 100 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 10 kA 100 % conforming to EN 60947-2 - 72 V DC 10 kA 100 % conforming to IEC 60947-2 - 72 V DC 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| local signalling | Trip indicator |
| Mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 2 |
| height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| Net weight | 0.215 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.5 cm |
| Package 1 Width | 1.7 cm |
| Package 1 Length | 7.5 cm |
| Package 1 Weight | 118.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 3.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 20.0 cm |
| Package 2 Weight | 1.42 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 132 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 16.237 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F74101
Main Document
Data Sheet : A9F74101
Reviews (0)
Recommended for you
-
0
Schneider A9F94163 |Miniature circuit-breaker, Acti9 iC60L, 1P, 63 A, C curve, 15 kA (IEC 60947-2)
-
0
Schneider A9F87463 | Miniature circuit-breaker, Acti9 iC60H, 4P, 63 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F87416 | Miniature circuit-breaker, Acti9 iC60H, 4P, 16 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F87110 | Miniature circuit-breaker, Acti9 iC60H, 1P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Reviews