Schneider A9F74104 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 4A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
Description
Schneider A9F74104 | Miniature circuit breaker (MCB), Acti9 iC60N, 1P, 4A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
Product Overview: Schneider A9F74104 | Miniature Circuit Breaker (MCB) – Acti9 iC60N – 1P – 4A – C Curve – 6000A
The Schneider Electric A9F74104 is a high-performance Miniature Circuit Breaker (MCB) from the trusted Acti9 iC60N range. This breaker is designed to ensure reliable protection against overloads and short-circuits in various residential, commercial, and industrial installations. It is a single-pole (1P) breaker with a rated current of 4A, C curve tripping, and a high breaking capacity of 6000A (IEC 60898-1) and up to 50kA (IEC 60947-2).
Key Features:
-
Brand: Schneider Electric
-
Series: Acti9 iC60N
-
Model Number: A9F74104
-
Product Type: Miniature Circuit Breaker (MCB)
-
Number of Poles: 1P (Single Pole)
-
Rated Current: 4 Amperes (4A)
-
Tripping Curve: C Curve
-
Breaking Capacity:
– 6 kA (IEC/EN 60898-1)
– Up to 50 kA (IEC/EN 60947-2) -
Rated Voltage: 230/400 V AC
-
Frequency: 50/60 Hz
Technical Specifications:
-
Mounting Type: DIN rail
-
Standards Compliance:
– IEC/EN 60898-1
– IEC/EN 60947-2 -
Connection Terminal: Tunnel type, 1.5–25 mm² cables
-
IP Rating: IP20 (with connected terminals)
-
Mechanical Durability: Up to 20,000 operations
-
Electrical Endurance: Up to 10,000 operations
Functional Features:
-
Protection:
– Against overload and short circuit -
C Curve:
– Designed for general loads with moderate inrush currents -
Status Indicator:
– Clear ON/OFF/tripped position -
Installation:
– Fast clip-on to DIN rail -
Accessory Ready:
– Compatible with iC60 auxiliaries
Applications:
-
Power circuits in homes and offices
-
Small control panels
-
Lighting protection
-
Branch circuits in commercial buildings
-
General-purpose electrical distribution
Benefits:
-
Compact, space-saving design
-
Fast installation and maintenance
-
High reliability and long lifespan
-
Easy troubleshooting with visual indicators
-
Fully compliant with international safety standards
Ideal For:
-
Electrical contractors
-
Building management systems
-
Panel manufacturers
-
Industrial automation solutions
-
Maintenance and facility engineers
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Product or component typee | Miniature circuit-breaker |
| Device short name | IC60N |
| Poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 4 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | EN 60898-1 IEC 60947-2 IEC 60898-1 EN 60947-2 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 50 kA 100 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 10 kA 100 % conforming to EN 60947-2 - 72 V DC 10 kA 100 % conforming to IEC 60947-2 - 72 V DC 15 kA 100 % conforming to EN 60947-2 - 12...60 V DC 15 kA 100 % conforming to IEC 60947-2 - 12...60 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| local signalling | Trip indicator |
| Mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 2 |
| height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| Net weight | 0.215 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.7 cm |
| Package 1 Width | 7.2 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 110.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 7.8 cm |
| Package 2 Width | 9.7 cm |
| Package 2 Length | 22.3 cm |
| Package 2 Weight | 1.386 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 132 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 15.742 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F74104
Main Document
Data Sheet : A9F74104
Reviews (0)
Recommended for you
-
0
Schneider A9F94163 |Miniature circuit-breaker, Acti9 iC60L, 1P, 63 A, C curve, 15 kA (IEC 60947-2)
-
0
Schneider A9F94140 | Miniature circuit-breaker, Acti9 iC60L, 1P, 40 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F87432 | Miniature circuit-breaker, Acti9 iC60H, 4P, 32 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F77320 | Miniature circuit-breaker, Acti9 iC60N, 3P, 20 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9F74203 | Miniature circuit-breaker, Acti9 iC60N, 2P, 3 A, C curve, 6000 A (IEC 60898-1), 50 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.