Schneider A9F74201 | Miniature circuit breaker (MCB), Acti9 iC60N, 2P, 1A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
Description
Schneider A9F74201| Miniature circuit breaker (MCB), Acti9 iC60N, 2P, 1A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
Schneider A9F74201: Unveiling the Power of Advanced Circuit Protection
Are you in need of robust circuit protection for your electrical systems? Look no further than the Schneider A9F74201 circuit breaker. In today’s dynamic world, where electrical safety is paramount, investing in high-quality circuit breakers is imperative. Schneider Electric, a renowned global leader in energy management and automation, presents the A9F74201, designed to safeguard your electrical infrastructure with unparalleled efficiency and reliability.
Understanding A9F74201 Circuit Breaker
The A9F74201 is more than just a circuit breaker; it’s a pinnacle of technological innovation in the realm of electrical protection. Boasting cutting-edge features and specifications, this device is engineered to meet the diverse needs of residential, commercial, and industrial applications.
Key Features
One of the standout features of the A9F74201 is its compact design, allowing for seamless integration into various electrical setups. Additionally, it offers:
- High Breaking Capacity: With a breaking capacity of 6 kA, the A9F74201 ensures optimal protection against short circuits and overloads.
- Advanced Tripping Mechanism: Equipped with state-of-the-art tripping mechanisms, this circuit breaker reacts swiftly to electrical faults, minimizing downtime and potential damages.
- Enhanced Safety: Built-in safety features, such as arc fault detection and thermal protection, provide an extra layer of security for your electrical systems.
Specifications
- Voltage Rating: 230/400 V AC
- Current Rating: 1 A
- Poles: 1P
- Frequency: 50/60 Hz
- Operating Temperature: -25°C to +70°C
Installation and Usage
Installing the A9F74201 circuit breaker is a breeze, thanks to its user-friendly design and comprehensive installation instructions. Whether you’re a seasoned electrician or a DIY enthusiast, setting up this device is straightforward and hassle-free. However, it’s crucial to adhere to safety protocols and local electrical codes during the installation process to ensure optimal performance and longevity.
Once installed, using the A9F74201 is equally simple. Its intuitive interface and ergonomic controls allow for effortless operation, making it an ideal choice for both residential and commercial settings.
Advantages of A9F74201
The A9F74201 offers a plethora of benefits that set it apart from traditional circuit breakers:
- Efficiency: With its high breaking capacity and advanced tripping mechanism, the A9F74201 delivers unmatched efficiency in safeguarding your electrical infrastructure.
- Safety Features: From arc fault detection to thermal protection, this circuit breaker prioritizes safety, giving you peace of mind knowing that your systems are well-protected.
- Reliability: Built to withstand the rigors of daily use, the A9F74201 is a reliable choice for all your circuit protection needs.
Comparison with Other Circuit Breakers
When compared to conventional circuit breakers, the A9F74201 stands out in terms of performance, reliability, and versatility. Its compact design, coupled with advanced features, makes it a preferred choice among discerning customers.
Applications and Industries
The versatility of the A9F74201 makes it suitable for a wide range of applications and industries, including:
- Residential: Protecting homes and apartments from electrical faults and overloads.
- Commercial: Safeguarding offices, retail establishments, and small businesses.
- Industrial: Ensuring the uninterrupted operation of factories, warehouses, and manufacturing facilities.
Maintenance and Troubleshooting
To ensure optimal performance and longevity, regular maintenance of the A9F74201 is essential. Here are some maintenance tips:
- Visual Inspection: Periodically inspect the circuit breaker for any signs of damage or wear.
- Testing: Conduct routine tests to verify the functionality of the tripping mechanism.
- Cleaning: Keep the device clean and free from debris to prevent malfunctions.
In the event of any issues or malfunctions, refer to the troubleshooting guide provided by Schneider Electric or consult a qualified electrician for assistance.
Cost and Availability
The cost of the A9F74201 circuit breaker may vary depending on factors such as quantity, distributor, and location. However, it offers excellent value for money considering its advanced features and superior performance. As for availability, the A9F74201 is widely stocked by authorized Schneider Electric distributors and retailers worldwide.
Customer Reviews and Feedback
Positive Feedback
Customers who have used the A9F74201 rave about its reliability, ease of installation, and robust performance. Many commend its advanced safety features, citing them as a key selling point.
Criticisms and Improvements
While the A9F74201 receives overwhelmingly positive feedback, some users have reported issues with compatibility and integration with certain electrical systems. Additionally, there have been suggestions for further enhancements, such as remote monitoring capabilities and customizable settings.
Conclusion
In conclusion, the Schneider A9F74201 circuit breaker is a testament to Schneider Electric’s commitment to innovation, quality, and safety. With its advanced features, compact design, and superior performance, it’s the perfect solution for safeguarding your electrical infrastructure against unforeseen hazards. Whether you’re a homeowner, business owner, or industry professional, investing in the A9F74201 is a step towards a safer and more reliable electrical system.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | IC60N |
| Poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 1 A |
| Network type | AC DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 EN 60898-1 EN 60947-2 IEC 60898-1 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 50 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 25 kA 100 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 10 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 10 kA 100 % conforming to EN 60947-2 - 72...125 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| local signalling | Trip indicator |
| Mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 4 |
| height | 85 mm |
| Width | 36 mm |
| Depth | 78.5 mm |
| Net weight | 0.25 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.2 cm |
| Package 1 Width | 3.5 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 224.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 2.73 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 20.0 cm |
| Package 2 Weight | 1.406 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 66 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 15.95 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9F94140 | Miniature circuit-breaker, Acti9 iC60L, 1P, 40 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F94110 | Miniature circuit-breaker, Acti9 iC60L, 1P, 10 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)
-
0
Schneider A9F87140 | Miniature circuit-breaker, Acti9 iC60H, 1P, 40 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F74303 | Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 3A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
-
0
Reviews
There are no reviews yet.