Schneider A9F87140 | Miniature circuit-breaker, Acti9 iC60H, 1P, 40 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Schneider A9F87140 | Miniature circuit-breaker, Acti9 iC60H, 1P, 40 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Description
Schneider A9F87140 | Miniature circuit-breaker, Acti9 iC60H, 1P, 40 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Technical Specifications A9F87140
-
Product Type: Miniature Circuit Breaker (MCB)
-
Model Number: A9F87140
-
Series: Acti9 iC60H
-
Number of Poles: 1P (Single Pole)
-
Rated Current: 40 A
-
Tripping Curve: Type C
-
Breaking Capacity (IEC 60898-1): 10,000 A
-
Breaking Capacity (IEC 60947-2): 15,000 A
-
Rated Operating Voltage: Up to 240/415 V AC
-
Frequency: 50/60 Hz
-
Mechanical Durability: Up to 20,000 operations
-
Electrical Durability: Up to 10,000 operations
-
Insulation Voltage: 500 V
-
Degree of Protection: IP20 (when enclosed)
-
Operating Temperature Range: -25°C to +70°C
-
Mounting: DIN rail compatible
-
Standards Compliance: IEC 60898-1, IEC 60947-2
Key Features
-
High Current Rating: With a 40 A capacity, this breaker is suitable for circuits with higher power demands.
-
C Curve Protection: Offers tripping at 5–10 times the rated current, ideal for general-purpose loads with moderate inrush.
-
Robust Construction: Designed for intensive operation in commercial and industrial environments.
-
Space-Saving Design: Compact module fits easily on DIN rails in standard distribution boards.
-
Long Service Life: High endurance for both mechanical switching and electrical operations.
-
Visual Trip Indicator: Allows quick status identification, aiding maintenance and diagnostics.
-
Enhanced Safety: Provides consistent protection, minimizing downtime and improving safety.
Applications
-
Commercial Circuits: Protects lighting systems, HVAC units, and general-purpose power outlets in commercial settings.
-
Light Industrial Use: Suitable for small motors, control systems, and power equipment in light industrial environments.
-
Residential High-Load Circuits: Ideal for circuits supplying electric ovens, high-capacity water heaters, or air conditioning systems.
-
Backup Power and Solar Systems: Useful in protecting circuits within inverter, UPS, and renewable energy subsystems.
-
Sub-Main Distribution Boards: Effective in supplying and protecting branch circuits from high load distribution points.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iC60H |
| Poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 40 A |
| Network type | AC DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | EN 60947-2 EN 60898-1 IEC 60898-1 IEC 60947-2 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 21 kA 50 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 15 kA 50 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 15 kA 100 % conforming to EN 60947-2 - 72 V DC 15 kA 100 % conforming to IEC 60947-2 - 72 V DC 20 kA 100 % conforming to EN 60947-2 - 12...60 V DC 20 kA 100 % conforming to IEC 60947-2 - 12...60 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| local signalling | Trip indicator |
| Mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 2 |
| height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| Net weight | 0.215 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…35 mm² rigid Single terminal (top or bottom) 1…25 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.800 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 124.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 8.000 cm |
| Package 2 Width | 9.800 cm |
| Package 2 Length | 22.500 cm |
| Package 2 Weight | 1.543 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 132 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 17.460 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F87140
Main Document
Data Sheet : A9F87140
Reviews (0)
Recommended for you
-
0
Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F94125 | Miniature circuit-breaker, Acti9 iC60L, 1P, 25 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)
-
0
Schneider A9F87432 | Miniature circuit-breaker, Acti9 iC60H, 4P, 32 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F87132 | Miniature circuit-breaker, Acti9 iC60H, 1P, 32 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.