Schneider A9F87410 | Miniature circuit-breaker, Acti9 iC60H, 4P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Schneider A9F87410 | Miniature circuit-breaker, Acti9 iC60H, 4P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Description
Schneider A9F87410 | Miniature circuit-breaker, Acti9 iC60H, 4P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Technical Specifications A9F87410
-
Product Type: Miniature Circuit Breaker (MCB)
-
Series: Acti9 iC60H
-
Reference Code: A9F87410
-
Number of Poles: 4P (Four-pole)
-
Rated Current (In): 10 A
-
Tripping Curve: C Curve (suitable for moderate inductive loads)
-
Breaking Capacity:
-
10 kA according to IEC 60898-1
-
15 kA according to IEC 60947-2
-
-
Rated Operational Voltage: 400/415 V AC
-
Frequency: 50/60 Hz
-
Degree of Protection: IP20 (higher with enclosure)
-
Mechanical Endurance: Up to 20,000 operations
-
Electrical Endurance: Up to 10,000 operations under load
-
Mounting: DIN rail mounting
-
Isolation Class: Class II (double insulation)
. Key Features
-
High Breaking Capacity: Offers strong short-circuit protection with a high interrupting capacity, ensuring electrical safety even in demanding environments.
-
C Curve Sensitivity: Designed to trip between 5 to 10 times the rated current, suitable for loads with moderate inrush currents such as motors and transformers.
-
Compact and Modular: Space-saving design suitable for modern distribution boards.
-
Easy Installation: Compatible with standard DIN rail mounting systems.
-
Reliable Indicators: Part of the Acti9 system, featuring clear status indicators for trip position and safe disconnection.
-
Environmentally Friendly: Made with recyclable materials and compliant with environmental standards.
-
Accessory Compatibility: Supports a wide range of add-ons including auxiliary contacts, earth leakage modules, and remote control devices.
. Applications
The Schneider A9F87410 MCB is versatile and can be used in various sectors, including:
a. Residential Applications
-
Protection of lighting circuits, sockets, and household appliances.
-
Ensures safety from overcurrents and short circuits in home installations.
b. Commercial Buildings
-
Widely used in malls, office complexes, and hotels to protect HVAC systems, elevators, lighting, and general power circuits.
c. Industrial Installations
-
Ideal for protecting small motors, control panels, and distribution boards in manufacturing facilities and workshops.
d. Electrical Distribution Boards
-
A preferred choice for sub-panels and main distribution boards due to its performance and compact size.
e. Renewable Energy Systems
-
Can be integrated into solar PV systems and wind installations to protect AC circuits in hybrid or grid-tied setups.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iC60H |
| Poles description | 4P |
| Number of protected poles | 4 |
| [In] rated current | 10 A |
| Network type | AC DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 EN 60898-1 IEC 60898-1 EN 60947-2 |
| Quality labels | NF |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 15 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 21 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 15 kA 100 % conforming to IEC 60947-2 - 180...250 V DC 15 kA 100 % conforming to EN 60947-2 - 180...250 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| local signalling | Trip indicator |
| Mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 8 |
| height | 85 mm |
| Width | 72 mm |
| Depth | 78.5 mm |
| Net weight | 0.5 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.5 cm |
| Package 1 Width | 7.0 cm |
| Package 1 Length | 9.4 cm |
| Package 1 Weight | 438.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 3 |
| Package 2 Height | 2.9 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 20.0 cm |
| Package 2 Weight | 1.378 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 33 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 15.64 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F87410
Main Document
Data Sheet : A9F87410
Reviews (0)
Recommended for you
-
0
Schneider A9F94140 | Miniature circuit-breaker, Acti9 iC60L, 1P, 40 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F94125 | Miniature circuit-breaker, Acti9 iC60L, 1P, 25 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)
-
0
Schneider A9F87420 | Miniature circuit-breaker, Acti9 iC60H, 4P, 20 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F74303 | Miniature circuit breaker (MCB), Acti9 iC60N, 3P, 3A, C curve, 6000A (IEC/EN 60898-1), 50kA (IEC/EN 60947-2)
-
0
Reviews
There are no reviews yet.