Schneider A9F87110 | Miniature circuit-breaker, Acti9 iC60H, 1P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Schneider A9F87110 | Miniature circuit-breaker, Acti9 iC60H, 1P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
Description
Schneider A9F87110 | Miniature circuit-breaker, Acti9 iC60H, 1P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
-
2. Technical Specifications A9F87110
-
Product Type: Miniature Circuit Breaker (MCB)
-
Model: A9F87110
-
Series: Acti9 iC60H
-
Poles: 1P (Single Pole)
-
Rated Current: 10 A
-
Tripping Curve: Type C
-
Breaking Capacity (IEC 60898-1): 10,000 A
-
Breaking Capacity (IEC 60947-2): 15,000 A
-
Rated Voltage: Up to 240/415 V AC
-
Frequency: 50/60 Hz
-
Mechanical Life: Up to 20,000 operations
-
Electrical Life: Up to 10,000 operations
-
Degree of Protection: IP20 (when installed inside an enclosure)
-
Insulation Voltage: 500 V
-
Ambient Operating Temperature: -25°C to +70°C
-
Installation Method: DIN rail
-
Compliance Standards: IEC 60898-1, IEC 60947-2
3. Key Features
-
Reliable Overcurrent Protection: Designed to trip under overload or short-circuit conditions to safeguard wiring and equipment.
-
C Curve Sensitivity: Allows brief inrush currents from devices like lights and motors without nuisance tripping.
-
Compact and Modular Design: Easily mounted on standard DIN rails, ideal for use in residential, commercial, and industrial panels.
-
Enhanced Safety Indicators: Clear visual indicators to display circuit breaker status (ON/OFF/tripped).
-
High Breaking Capacity: Withstands high fault currents (up to 15 kA) for added protection in high-risk environments.
-
Long Operational Life: Durable design supports extensive mechanical and electrical usage.
-
Wide Operating Temperature: Built to perform in challenging environmental conditions.
4. Applications
-
Residential Circuits: Suitable for lighting and small appliance circuits in homes.
-
Small Commercial Installations: Ideal for branch circuits in offices, retail shops, and public areas.
-
Control Panels: Commonly used in control boards for protection of control wiring and small devices.
-
Light Industrial Applications: Supports safe operation in low-load sections of industrial environments.
-
-
Renewable Energy Subsystems: Can be used in low-current sections of solar or wind energy systems.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | iC60H |
| Poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 10 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 IEC 60898-1 EN 60898-1 EN 60947-2 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 8 x In +/- 20 % |
| [Ics] rated service breaking capacity | 21 kA 50 % conforming to EN 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...60 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 230 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 230 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 100...133 V AC 50/60 Hz 15 kA 50 % conforming to EN 60947-2 - 100...133 V AC 50/60 Hz 15 kA 100 % conforming to EN 60947-2 - 72 V DC 15 kA 100 % conforming to IEC 60947-2 - 72 V DC 20 kA 100 % conforming to EN 60947-2 - 12...60 V DC 20 kA 100 % conforming to IEC 60947-2 - 12...60 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| local signalling | Trip indicator |
| Mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 2 |
| height | 85 mm |
| Width | 18 mm |
| Depth | 78.5 mm |
| Net weight | 0.215 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 1.8 cm |
| Package 1 Width | 7.5 cm |
| Package 1 Length | 9.4 cm |
| Package 1 Weight | 109.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 8.2 cm |
| Package 2 Width | 9.8 cm |
| Package 2 Length | 22.2 cm |
| Package 2 Weight | 1.392 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 132 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 15.799 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9F87110
Main Document
Data Sheet : A9F87110
Reviews (0)
Recommended for you
-
0
Schneider A9F94140 | Miniature circuit-breaker, Acti9 iC60L, 1P, 40 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F94132 | Miniature circuit-breaker, Acti9 iC60L, 1P, 32 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F87132 | Miniature circuit-breaker, Acti9 iC60H, 1P, 32 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F77163 | Miniature circuit-breaker, Acti9 iC60N, 1P, 63 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9F77140 | Miniature circuit-breaker, Acti9 iC60N, 1P, 40 A, C curve, 6000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.