 Schneider A9R10225 | Acti 9 iID – RCCB – 2P – 25A – 10mA – type AC

. Technical Specifications A9R10225

  • Brand: Schneider Electric

  • Series: Acti9 iID

  • Model Number: A9R10225

  • Device Type: RCCB (Residual Current Circuit Breaker)

  • Number of Poles: 2 Poles

  • Rated Current (In): 25 Amperes

  • Rated Residual Operating Current (IΔn): 10 mA

  • Sensitivity Type: Type AC (detects pure sinusoidal AC leakage currents)

  • Rated Voltage (Ue): 230/240V AC (single-phase)

  • Frequency: 50/60 Hz

  • Short-Circuit Withstand Capacity: 6 kA (when used with appropriate backup protection)

  • Mounting: DIN rail, 2 modules width (36 mm)

  • Degree of Protection: IP20 (front panel), IP40 (in enclosure)

  • Operating Temperature: -25°C to +60°C

  • Standards: IEC/EN 61008-1 compliant

. Key Features

  • High Sensitivity (10 mA): Provides enhanced protection against electrical shock and is suitable for personal safety applications.

  • Type AC Detection: Detects AC earth leakage currents (suitable for general-purpose use in typical residential and light commercial installations).

  • Full Pole Disconnection: Disconnects both live and neutral, ensuring maximum safety.

  • Compact Design: Takes up only 2 DIN rail modules (36 mm), ideal for compact distribution boards.

  • Status Indicator: Clear mechanical toggle and trip indicator for quick fault identification.

  • Reliable Mechanism: Proven Schneider technology ensures consistent performance and long-term reliability.

  • Double Insulated Housing: Enhances electrical safety during handling and installation.

  • Tool-Free Mounting: Quick to install on standard DIN rails without the need for special tools.

  • Test Button: Built-in test function allows for periodic checking of proper functionality.

. Applications

The Schneider A9R10225 RCCB is particularly suitable for applications that demand very high safety standards and low leakage current protection:

  • Residential Installations: Bathrooms, kitchens, or bedrooms to protect people from electrical shock.

  • Healthcare Facilities: Clinics, hospitals, or patient rooms where sensitive residual current protection is critical.

  • Public Buildings: Schools, offices, hotels, and other public access areas.

  • Special Equipment Protection: Where even small leakage currents (under 10mA) could pose a safety risk.

  • Wet Areas and Outdoor Circuits: Such as water heaters, pools, or garden installations.

Additional information

brands

Schneider Electric

Specifications

Main
Range Acti9
Product name Acti9 iID
Product or component type Residual current circuit breaker (RCCB)
Device short name iID
Poles description 2P
Neutral position Left
[In] rated current 25 A
Network type AC
Earth-leakage sensitivity 10 mA
earth-leakage protection time delay Instantaneous
Earth-leakage protection class Type AC
Complementary
device location in system Outgoer
Network frequency 50/60 Hz
[Ue] rated operational voltage 220...240 V AC 50/60 Hz
Residual current tripping technology Voltage independent
Rated breaking and making capacity Idm 1500 A Im 1500 A
Rated conditional short-circuit current 10 kA
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 6 kV
Contact position indicator Yes
control type Toggle
Mounting mode Clip-on
mounting support DIN rail
9 mm pitches 4
height 91 mm
Width 36 mm
Depth 73.5 mm
Net weight 0.21 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability AC-1: 15000 cycles
Locking options description Padlocking device
Connections - terminals Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule
Wire stripping length 14 mm for top or bottom connection
Tightening torque 3.5 N.m top or bottom
Environment
Standards EN/IEC 61008-1
Product certifications EAC
IP degree of protection IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Pollution degree 3
Electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
Ambient air temperature for operation -5…60 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.200 cm
Package 1 Width 9.500 cm
Package 1 Length 10.000 cm
Package 1 Weight 221.000 g
Unit Type of Package 2 S03
Number of Units in Package 2 54
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 12.500 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download