Schneider A9R14291 | Acti 9 iID – RCCB – 2P – 100A – 300mA – type AC
Schneider A9R14291 | Acti 9 iID – RCCB – 2P – 100A – 300mA – type AC
Description
Schneider A9R14291 | Acti 9 iID – RCCB – 2P – 100A – 300mA – type AC
Technical Specifications A9R14291
-
Product Reference: A9R14291
-
Series: Acti 9 iID
-
Device Type: RCCB (Residual Current Circuit Breaker)
-
Number of Poles: 2 (Double Pole)
-
Rated Current (In): 100 Amps
-
Rated Residual Operating Current (IΔn): 300 mA
-
Residual Current Type: Type AC (sinusoidal AC currents)
-
Rated Voltage: 230/400V AC
-
Frequency: 50/60 Hz
-
Mounting: DIN Rail
-
Degree of Protection: IP20 (with terminal cover)
-
Standard Compliance: IEC 61008-1
Key Features and Benefits
-
High Rated Current (100A): Suitable for main circuits or large loads in residential, commercial, or industrial applications.
-
300mA Sensitivity: Designed for fire prevention, reducing the risk of electrical fires due to persistent earth leakage currents.
-
Type AC Performance: Accurately detects sinusoidal AC residual currents.
-
Double Pole Disconnection: Ensures complete isolation of both phase and neutral conductors.
-
Fast Tripping Response: Provides quick interruption of power in case of detected imbalance.
-
Test Function: Built-in test button ensures the RCCB can be manually verified for correct operation.
-
Compact DIN Rail Design: Space-saving and easy to install in distribution panels.
-
Low Maintenance: Durable design for long-term safety and reliability.
Applications
Fire Protection:
-
The 300mA sensitivity level is ideal for protecting installations against insulation faults that may not be dangerous to humans but pose a risk of fire over time.
Main Distribution Panels:
-
Can be installed as a main protection device for large buildings, workshops, or commercial facilities.
General Purpose Installations:
-
Suitable for offices, residential buildings, and public institutions that require protection at the property level rather than individual circuit level.
Equipment Protection:
-
Offers leakage protection for non-critical circuits where 30mA sensitivity is not required, such as HVAC systems, lighting, or heavy equipment.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Acti9 |
|---|---|
| Product name | Acti9 iID |
| Product or component type | Residual current circuit breaker (RCCB) |
| Device short name | iID |
| Poles description | 2P |
| Neutral position | Left |
| [In] rated current | 100 A |
| Network type | AC |
| Earth-leakage sensitivity | 300 mA |
| earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type AC |
| device location in system | Outgoer |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 220...240 V AC 50/60 Hz |
| Residual current tripping technology | Voltage independent |
| Rated breaking and making capacity | Idm 1500 A Im 1500 A |
| Rated conditional short-circuit current | 10 kA |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Contact position indicator | Yes |
| control type | Toggle |
| Mounting mode | Clip-on |
| mounting support | DIN rail |
| 9 mm pitches | 4 |
| height | 91 mm |
| Width | 36 mm |
| Depth | 73.5 mm |
| Net weight | 0.21 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | AC-1: 10000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Standards | EN/IEC 61008-1 |
|---|---|
| Product certifications | SNI |
| IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
| Pollution degree | 3 |
| Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 |
| Ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.300 cm |
| Package 1 Width | 4.000 cm |
| Package 1 Length | 10.200 cm |
| Package 1 Weight | 210.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 54 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 11.778 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61515 | miniature circuit breaker – C60H – 1 pole – 32 A – C curve
-
0
Schneider A9N26946 | MX Shunt Trip MX plus 1 OF 220-415Vac dc
-
0
Schneider A9N26929 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9K24316 | Miniature circuit-breaker, Acti9 iK60N, 3P, 16 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews
There are no reviews yet.