Schneider A9K24325 | Miniature circuit-breaker, Acti9 iK60N, 3P, 25 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24325 | Miniature circuit-breaker, Acti9 iK60N, 3P, 25 A, C curve, 6000 A (IEC 60898-1)
Description
Schneider A9K24325 | Miniature circuit-breaker, Acti9 iK60N, 3P, 25 A, C curve, 6000 A (IEC 60898-1)
Product Specifications
The Schneider A9K24325 is a high-performance miniature circuit breaker (MCB) from the Acti9 iK60N series. It provides essential protection for electrical installations by interrupting the circuit in the event of overload or short-circuit faults.
-
Brand: Schneider Electric
-
Series: Acti9 iK60N
-
Product Type: Miniature Circuit Breaker (MCB)
-
Number of Poles: 3 poles (3P)
-
Rated Current: 25 Amperes (A)
-
Tripping Curve: Type C
-
Breaking Capacity: 6000 Amperes (A)
-
Standard Compliance: IEC 60898-1
-
Voltage Rating: Typically 230/400V AC (dependent on system configuration)
-
Mounting: DIN rail mounting
-
Terminal Type: Screw terminals with IP20 finger-safe protection
-
Operating Frequency: 50/60 Hz
-
Ambient Temperature Range: -25°C to +70°C
-
Electrical Endurance: 20,000 operations (typical)
. Key Features
The A9K24325 MCB is engineered for safety, reliability, and easy integration into distribution panels. Its key features include:
-
Reliable Protection
Provides fast and accurate disconnection in case of overloads or short circuits, preventing damage to equipment and reducing fire risks. -
C Curve Tripping Characteristics
The Type C tripping curve makes it suitable for general-purpose use, including resistive and moderately inductive loads such as lighting, small motors, and household appliances. -
High Breaking Capacity (6 kA)
Rated at 6000 A according to IEC 60898-1, it can safely interrupt fault currents found in residential and commercial installations. -
Three-Phase Compatibility
With three poles, this device is designed for use in three-phase systems, offering simultaneous protection for all three live conductors. -
Compact DIN Rail Design
Easy to install in any standard distribution board or consumer unit, saving space and simplifying wiring. -
Safe and Durable Construction
Includes IP20 protection at terminals, finger-safe design, and robust housing to ensure operator safety and long-lasting performance. -
Visual ON/OFF Status Indicator
Allows users and technicians to quickly check whether the breaker is in the ON or OFF position, aiding in diagnostics and maintenance. -
Part of the Acti9 System
Fully compatible with other Acti9 accessories and devices, including auxiliaries, busbars, and monitoring units for system expansion.
. Applications
The A9K24325 is suitable for a wide range of installations where dependable overcurrent protection is required. Common applications include:
-
Residential Distribution Boards
Used to protect lighting circuits, socket outlets, and kitchen appliances in homes and apartment buildings. -
Commercial Installations
Suitable for offices, retail spaces, and educational facilities, providing protection for lighting, HVAC, and general-purpose loads. -
Industrial Control Panels
Protects auxiliary equipment, small motors, and control wiring in light industrial systems. -
Three-Phase Equipment Protection
Ideal for machinery, pumps, or air conditioning units operating on a three-phase power supply. -
Renewable Energy Systems
Used in solar power installations and backup generator systems to protect downstream circuits. -
Temporary and Mobile Units
Can be installed in portable distribution boards used at construction sites or events to ensure electrical safety.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iK60 |
| product or component type | Miniature circuit-breaker |
| Device short name | iK60N |
| Poles description | 3P |
| Number of protected poles | 3 |
| [In] rated current | 25 A at 30 °C |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| Suitability for isolation | Yes conforming to EN/IEC 60898-1 |
| Standards | EN/IEC 60898-1 |
| Product certifications | SNI |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 5...10 x In |
| [Ics] rated service breaking capacity | 6000 A 100 % conforming to EN/IEC 60898-1 - 400 V AC 50/60 Hz |
| Limitation class | 3 conforming to EN/IEC 60898-1 |
| [Ui] rated insulation voltage | 440 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60898-1 |
| Contact position indicator | No |
| Control type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 78.5 mm |
| net weight | 300 g |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Tunnel type terminal (top or bottom) 1…25 mm² rigid Tunnel type terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 |
|---|---|
| Pollution degree | 2 conforming to EN/IEC 60898-1 |
| Overvoltage category | II |
| Ambient air temperature for operation | -25…60 °C |
| ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 7.500 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 298.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 8.500 cm |
| Package 2 Width | 10.000 cm |
| Package 2 Length | 22.000 cm |
| Package 2 Weight | 1.250 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 44 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 14.147 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : A9K24325
Main Document
Data Sheet : A9K24325
Reviews (0)
Recommended for you
Schneider A9K24220 | Miniature circuit-breaker, Acti9 iK60N, 2P, 20 A, C curve, 6000 A (IEC 60898-1)
-
0
Schneider A9K24225 | Miniature circuit-breaker, Acti9 iK60N, 2P, 25 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24363 | Miniature circuit-breaker, Acti9 iK60N, 3P, 63 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24320 | miniature circuit breaker – iK60N – 3P – 20 A – C curve
-
0
Reviews
There are no reviews yet.