Schneider G12E3A32 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 32A rating, TMD trip unit, adjustable thermal protection
Schneider G12E3A32 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 32A rating, TMD trip unit, adjustable thermal protection
Description
Schneider G12E3A32 | Circuit breaker, GoPact MCCB 125, 3 poles, 15kA at 415VAC, 32A rating, TMD trip unit, adjustable thermal protection
Technical Specifications G12E3A32
-
Product Name: Schneider Electric G12E3A32
-
Product Type: Molded Case Circuit Breaker (MCCB)
-
Series: GoPact MCCB 125
-
Number of Poles: 3 poles
-
Rated Current (In): 32 Amps
-
Frame Size: 125 A
-
Rated Operational Voltage (Ue): Up to 415 VAC
-
Breaking Capacity (Icu): 15 kA at 415 VAC
-
Trip Unit Type: TMD (Thermal Magnetic Trip Unit)
-
Thermal Trip Setting: Adjustable – customizes overload protection
-
Magnetic Trip Setting: Fixed – ensures fast action on short-circuits
-
Frequency: 50/60 Hz
-
Mounting Type: Fixed mounting (suitable for panels or distribution boards)
-
Conformity Standards: IEC 60947-2
-
Utilization Category: AC-22A (general use for mixed resistive and inductive loads)
Key Features G12E3A32
-
Precision Protection for Moderate Loads
With a 32A rating, this MCCB offers optimal protection for medium-duty circuits such as lighting banks, power outlets, or motor feeders. -
Adjustable Thermal Trip
Enables installers to fine-tune the overload response to match specific application needs, enhancing both system safety and reliability. -
Fixed Magnetic Trip Response
Offers instant protection against short-circuit faults, minimizing the risk of damage to equipment and improving personnel safety. -
Compact, Rugged Construction
Space-saving design with high mechanical strength makes it suitable for dense panels and tough industrial environments. -
Simple Integration
Standardized size and front-facing terminals ensure fast installation and easy replacement in existing setups. -
Cost-Efficient & Globally Compliant
Provides Schneider Electric’s trusted quality at an economical price, with full compliance to international standards.
Applications
-
Commercial & Retail Buildings
Protects lighting panels, small air conditioning units, and socket circuits in offices, malls, restaurants, and showrooms. -
Industrial Workshops & Factories
Suitable for safeguarding small motor loads, control systems, and machine auxiliary circuits that require 32A protection. -
Renewable Energy Panels
Can be used in low-power AC distribution segments of solar or wind systems where branch protection is required. -
IT & Communication Facilities
Provides dependable circuit protection for network equipment, power supplies, and infrastructure distribution boards. -
Infrastructure Installations
Applied in hospitals, schools, public utility buildings, and transit systems for protecting moderate-load electrical sub-circuits. -
UPS & Emergency Power Systems
Ideal for protecting 32A-rated backup power lines in critical systems needing constant uptime.
.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | GoPact MCCB |
|---|---|
| product or component type | Circuit breaker |
| Product name | GoPact MCCB 125 |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 32 A at 40 °C |
| [Ue] rated operational voltage | 415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 15 kA Icu at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Performance level | E 15 kA 380/415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 440 V AC conforming to EN/IEC 60947-2 |
|---|---|
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 15 kA at 380/415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA at 220/230 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Mechanical durability | 30000 cycles |
| Electrical durability | 8000 cycles at 415 V In |
| Power dissipation per pole | 18.7 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Screw terminals |
| Connection pitch | 25 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 32 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.8...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 10 x In |
| Width (W) | 75 mm |
| Height (H) | 130 mm |
| Depth (D) | 60 mm |
| net weight | 0.7 kg |
| Colour | Grey (RAL 7035) |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H |
|---|---|
| Overvoltage category | III |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…55 °C |
| ambient air temperature for storage | -35…85 °C |
| Operating altitude | 0...2000 m without derating 2000...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.4 cm |
| Package 1 Width | 8.5 cm |
| Package 1 Length | 13.9 cm |
| Package 1 Weight | 908 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 8 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 7.579 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 128 |
| Package 3 Height | 75 cm |
| Package 3 Width | 60 cm |
| Package 3 Length | 80 cm |
| Package 3 Weight | 129.764 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9N61521 | miniature circuit breaker – C60H – 2 poles – 1 A – C curve
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18479 | Miniature circuit-breaker, Acti9 C120H, 4P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9N18446 | Miniature circuit-breaker, Acti9 C120H, 1P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9L40101 | iPRD40r modular surge arrester – 1P – 350V – with remote transfert
-
0
Reviews
There are no reviews yet.