Schneider C12H6TM160L | Circuit breaker, ComPacT NSXm 160H, 70kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 160A, EverLink lugs
Schneider C12H6TM160L | Circuit breaker, ComPacT NSXm 160H, 70kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 160A, EverLink lugs
Description
Schneider C12H6TM160L
Introduction
The Schneider C12H6TM160L is a robust and efficient circuit breaker designed to protect electrical distribution systems from overloads and short circuits. As part of Schneider Electric’s extensive range of circuit breakers, the C12H6TM160L is essential for ensuring the safety and reliability of electrical circuits in industrial and commercial environments. This article provides an in-depth look at the features, applications, benefits, and other aspects of the Schneider C12H6TM160L, offering a comprehensive guide for potential users.
What is the Schneider C12H6TM160L?
it is a high-performance circuit breaker that combines advanced protection features with a compact design. It is engineered to interrupt fault currents effectively, protecting electrical systems and equipment from damage. Key features of the C12H6TM160L include:
- High Breaking Capacity: Capable of handling significant fault currents to ensure safety.
- Compact Design: Fits easily into various electrical panels, even in space-constrained environments.
- Advanced Protection Mechanisms: Includes thermal and magnetic trip units for precise and reliable protection.
Technical Specifications
Understanding the technical specifications of it is crucial for determining its suitability for specific applications. Here are the primary specifications:
- Rated Current: 160A, suitable for handling substantial electrical loads.
- Breaking Capacity: High fault current interruption capability, ensuring safety and reliability.
- Voltage Rating: Compatible with standard voltage levels used in industrial and commercial settings.
- Mechanical Endurance: Designed for a high number of operating cycles, ensuring long-term durability.
- Compliance: Meets international safety standards, ensuring reliable performance and compliance with regulations.
Applications of Schneider C12H6TM160L
The versatility of it makes it suitable for a wide range of applications, including:
- Industrial Use: Protects machinery and equipment in manufacturing plants and processing facilities.
- Commercial Use: Ensures the safety of electrical systems in office buildings, shopping centers, and other commercial properties.
- Specific Examples: Used in the protection of motor control centers, distribution panels, and power supply units.
Benefits of Using Schneider C12H6TM160L
Opting for it brings several significant benefits:
- Enhanced Safety: Provides reliable protection against electrical faults, reducing the risk of fires and equipment damage.
- Reliability and Durability: Engineered to withstand harsh operating conditions and frequent use.
- Cost-Effectiveness: Offers a balance between initial investment and long-term savings through reduced maintenance and downtime.
Installation and Setup
Installing it requires careful attention to detail. Here’s a simplified installation guide:
- Mount the Circuit Breaker: Securely install the C12H6TM160L in the appropriate location within the electrical panel.
- Connect the Wiring: Ensure proper connections to the input and output terminals, adhering to the manufacturer’s guidelines.
- Check the Settings: Configure the trip settings according to the specific requirements of the electrical system.
- Test the Installation: Perform initial tests to verify correct installation and functionality.
Maintenance and Troubleshooting
Regular maintenance of it is crucial for optimal performance. Follow these tips:
- Routine Inspections: Periodically check for signs of wear, loose connections, and other potential issues.
- Cleaning: Keep the breaker and surrounding area clean from dust and debris.
- Firmware Updates: If applicable, ensure the device’s firmware is up to date.
- Troubleshooting Common Issues: Address problems such as nuisance tripping by verifying load conditions and trip settings
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of products | ComPacT NSXm new generation |
| Device short name | NSXm 160H |
| product or component type | Circuit breakers |
| Device applications | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 160 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilization category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50 /60 Hz conforming to IEC 60947-2 |
| Performance level | H 70 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 12.21W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connections | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…70 mm², flexible copper 1 Everlink lug wire size 2.5…95 mm², rigid or stranded copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 12 modules |
| Trip unit rating | 160 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x Print |
| Long-time protection delay adjustment type p | Fixed |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [ii] instant protection pick-up adjustment range | 1250A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signaling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 108mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.42 kg |
| Color | Gray (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | First |
| Package 1 Height | 13 cm |
| Package 1 Width | 12 cm |
| Package 1 Length | 22 cm |
| Package 1 Weight | 1.6kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 10.19 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 144 |
| Package 3 Height | 150 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 254.49 kg |