Description

Schneider LV426555 Compact

it circuit breaker is a cornerstone in modern electrical systems, providing robust protection against overloads and short circuits. This comprehensive guide explores its features, installation procedures, maintenance tips, troubleshooting advice, and future innovations.

Understanding the Vital Role of Circuit Protection in Electrical Systems

Circuit protection is crucial in electrical systems to safeguard equipment and personnel from potential hazards such as electrical fires and equipment damage. Circuit breakers like the it play a pivotal role in ensuring safe and reliable electrical operation.

Overview of Schneider LV426555 Compact

itt is a high-performance molded case circuit breaker (MCCB) designed to provide reliable protection in industrial and commercial environments. With its advanced features and compact design, it offers an ideal solution for ensuring electrical safety and efficiency.

Key Features and Specifications

  • Rated Current: 250A
  • Voltage Rating: 690V AC
  • Breaking Capacity: 50 kA at 415V AC
  • Number of Poles: 3
  • Trip Unit Technology: Advanced electronic trip units for precise protection
  • Compact Design: Space-saving form factor
  • Standards Compliance: IEC 60947-2

Importance of Schneider LV426555 Compact in Industrial and Commercial Environments

The Schneider LV426555 Compact plays a critical role in industrial and commercial environments by providing reliable protection against electrical faults. Its advanced trip unit technology and high breaking capacity ensure quick and accurate response to overloads and short circuits, minimizing downtime and maximizing safety.

Enhancing Safety and Efficiency

By incorporating the Schneider LV426555 Compact into electrical systems, users can enhance safety and efficiency. The breaker’s ability to quickly interrupt current flow in the event of a fault prevents damage to equipment and reduces the risk of electrical accidents, ensuring uninterrupted operation and maintaining productivity.

Installation and Setup Guide for Schneider LV426555 Compact

Proper installation is essential to ensure the Schneider LV426555 Compact operates effectively. Here’s a step-by-step guide:

  1. Preparation: Disconnect all power sources before installation.
  2. Mounting: Secure the breaker in a suitable enclosure, ensuring proper alignment.
  3. Wiring: Connect input and output terminals following the wiring diagram provided in the user manual.
  4. Configuration: Set trip unit parameters according to specific requirements.
  5. Testing: Conduct tests to verify correct installation and operation.

Maintenance Best Practices for Schneider LV426555 Compact

Regular maintenance is key to maximizing the performance and longevity of the Schneider LV426555 Compact. Follow these best practices:

  • Routine Inspections: Regularly inspect the breaker for signs of wear or damage.
  • Cleaning: Keep the breaker clean and free from dust and debris.
  • Functional Testing: Perform regular tests to ensure the trip unit and mechanical components are functioning correctly.
  • Professional Servicing: Schedule routine maintenance by qualified professionals to address any potential issues.

Maximizing Performance and Longevity

Adhering to a regular maintenance schedule ensures the Schneider LV426555 Compact remains in optimal condition, providing reliable protection against electrical faults. Promptly addressing any issues that arise helps prevent minor problems from escalating into major failures, minimizing downtime and ensuring safety.

Troubleshooting Common Issues with Schneider LV426555 Compact

Even the most reliable circuit breakers may encounter issues. Here are some common problems and their solutions:

  • Tripping: Check for overloads or short circuits and adjust trip unit settings if necessary.
  • Failure to Trip: Verify proper installation and configuration of the trip unit.
  • Mechanical Issues: Inspect for loose connections or mechanical obstructions.

Solutions for Swift Resolutions

For minor issues, refer to the user manual for detailed troubleshooting steps. If problems persist, consult Schneider’s technical support or a qualified electrician for assistance to ensure continued protection and safety.

Innovations and Future Trends of Schneider LV426555 Compact

The Schneider LV426555 Compact is at the forefront of circuit protection technology. Future innovations may include enhanced connectivity, integration with smart grid technologies, and advanced analytics for improved performance and safety.

Embracing Technological Advancements for Enhanced Circuit Protection

As technology continues to evolve, the Schneider LV426555 Compact will incorporate new advancements to ensure it remains a top choice for reliable and efficient circuit protection in various applications.

Conclusion

The Schneider LV426555 Compact circuit breaker is an essential component for ensuring electrical safety and efficiency in industrial and commercial environments. By understanding its features, installation process, maintenance requirements, and troubleshooting techniques, users can leverage its benefits to achieve optimal electrical protection.

Additional information

brands

Schneider Electric

Specifications

Main
Range ComPact
Product name ComPact NSXm
Range of product ComPact NSXm
Device short name NSXm 63H
Product or component type Circuit breaker
Device application Distribution Protection
Number of poles 3P
Protected poles description 3D
[In] rated current 63 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level H 70 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
control type Toggle
Circuit breaker mounting mode By screws Clip-on
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 10000 cycles at 440 V In 20000 cycles at 440 V In/2 5000 cycles at 690 V In 10000 cycles at 690 V In/2
mounting support Plate DIN rail
Connection terminals Compression lug/busbar
Connection pitch 35 mm with spreaders 27 mm without spreaders
9 mm pitches 9 module
Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rating 63 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[Im] magnetic protection pick-up range 800 A
earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX
Width (W) 81 mm
Height (H) 137 mm
Depth (D) 80 mm
Net weight 1.06 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
product certifications CCC EAC Marine
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating 2000...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9 cm
Package 1 Width 12.5 cm
Package 1 Length 21 cm
Package 1 Weight 1.3 kg
Unit Type of Package 2 S03
Number of Units in Package 2 9
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 12.29 kg
Unit Type of Package 3 P12
Number of Units in Package 3 216
Package 3 Height 110 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 304.89 kg
Contractual warranty
Warranty 12 months

Main Document

Main Document

Data Sheet : LV426555

Main Document