Description

Schneider C11N44V050L: A Comprehensive Guide

Introduction

In today’s fast-paced technological landscape, the Schneider C11N44V050L emerges as a key player in electrical and automation systems. Its advanced features and robust design make it an essential component for various applications, from industrial automation to residential electrical setups. This guide delves into the specifics of it, highlighting its features, benefits, and usage.

What is Schneider C11N44V050L?

it is a high-performance electrical component designed to enhance the efficiency and reliability of automation systems. It is engineered to meet the demands of modern electrical installations, providing superior performance and durability.

Technical Specifications

Understanding the technical details of it is crucial for its effective application.

  • Dimensions and Weight: The compact design facilitates easy integration into various systems.
  • Voltage Rating: Suitable for diverse voltage inputs, ensuring versatility.
  • Current Rating: Capable of handling substantial current loads, enhancing operational efficiency.
  • Environmental Tolerances: Designed to operate in a wide range of environmental conditions, from extreme heat to cold.

Applications of Schneider C11N44V050L

Industrial Uses

In industrial settings, it is pivotal for automating processes, increasing productivity, and ensuring operational safety.

Residential Applications

For residential use, this component integrates seamlessly into home electrical systems, enhancing convenience and energy efficiency.

Commercial Settings

In commercial buildings, it helps manage electrical systems effectively, reducing energy consumption and operational costs.

Installation Process

Pre-installation Checklist

Ensure you have all the necessary tools and follow the recommended safety guidelines before beginning the installation process.

Step-by-Step Guide

  1. Preparation: Gather all required tools and review the installation manual.
  2. Mounting: Secure the device in the designated location using appropriate hardware.
  3. Wiring: Connect the wires according to the provided wiring diagram.
  4. Testing: Conduct a functionality test to confirm proper installation.

Safety Measures

Always adhere to safety protocols to prevent accidents during installation. Wear appropriate protective gear and disconnect power sources when working with electrical components.

Benefits of Using Schneider C11N44V050L

High Performance

it is renowned for its high performance, ensuring reliable operation even in demanding environments.

Energy Efficiency

Designed to optimize energy consumption, this component helps reduce operational costs significantly.

Cost Savings

With its durability and efficiency, it offers excellent value for money, making it a cost-effective solution for various applications.

Comparing Schneider C11N44V050L with Similar Products

Competitors in the Market

Competitors include products from Siemens, ABB, and General Electric, each offering unique features.

Detailed Comparison

While competitors provide various benefits, it stands out for its superior reliability, energy efficiency, and overall performance.

Maintenance Guidelines

Routine Maintenance Tips

  • Inspection: Regularly inspect the device for any signs of wear or damage.
  • Cleaning: Keep the device clean to ensure optimal performance.
  • Testing: Periodically test its functionality to detect issues early.

Common Issues and Solutions

  • No Power: Check connections and ensure the power supply is stable.
  • Overheating: Ensure proper ventilation and avoid overloading the device.
  • Intermittent Performance: Inspect for loose connections or wiring issues.

Additional information

brands

Schneider Electric

Specifications

Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 63N
product or component type Earth leakage circuit breaker
Device application Distribution
poles description 4P
Protected poles description 4D
Neutral position Left
[In] rated current 50 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name MicroLogic 4.1
Trip unit technology Electronic
Trip unit protection functions LSoIR
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Power dissipation per pole 1.88 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…70 mm², fine stranded copper 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
Connection pitch 35 mm with spreaders 27 mm without spreaders
9 mm pitches 12 module
Trip unit rating 50 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 20...50 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 200 s at 1.5 x Ir 8 s at 6 x Ir 5 s at 7.2 x Ir
Neutral protection settings 1 x Ir (4D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 750 A
Earth-leakage protection Integrated
Earth-leakage protection class Class A Class AC
Earth-leakage protection sensitity adjustment type IΔn Adjustable
[IΔn] earth-leakage protection sensitivity adjustment range 30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A
Earth-leakage sensitivity 30 mA for class A 100 mA for class A 300 mA for class A 500 mA for class A 1 A for class A 30 mA for class AC 100 mA for class AC 300 mA for class AC 500 mA for class AC 1 A for class AC 3 A for class AC 5 A for class AC
Earth-leakage protection time delay adjustement type Δt Adjustable
[Δt] Earth-leakage protection time delay adjustment range 0 ms 60 ms 150 ms 500 ms 1000 ms
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 108 mm
Height (H) 144 mm
Depth (D) 80 mm
net weight 1.63 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating 5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.0 cm
Package 1 Width 13.0 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.788 kg
Unit Type of Package 2 S03
Number of Units in Package 2 4
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.522 kg

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider C11N44V050L | Circuit breaker, ComPacT NSXm 63N, 50kA/415VAC, 4 poles, MicroLogic 4.1 trip unit 50A, EverLink lugs”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products