Schneider C11H6TM050L | Circuit breaker ComPacT NSXm H (70kA at 415VAC), 4 Poles 3d, 50A rating TMD trip unit, EverLink connectors
Schneider C11H6TM050L | Circuit breaker ComPacT NSXm H (70kA at 415VAC), 4 Poles 3d, 50A rating TMD trip unit, EverLink connectors
Description
Schneider C11H6TM050L
Introduction
In the realm of industrial automation, finding a reliable and efficient component is crucial. Enter the Schneider C11H6TM050L, a product that stands out for its versatility and performance. But what makes this component so special? Why should you consider integrating it into your systems? Let’s dive deep into understanding the Schneider C11H6TM050L, its specifications, applications, and benefits.
What is Schneider C11H6TM050L?
it is a cutting-edge component designed to enhance industrial automation systems. Known for its robust construction and advanced features, this device is pivotal in ensuring seamless operations in various applications. From industrial machinery to sophisticated home automation systems, it is designed to meet diverse needs with unparalleled efficiency.
Technical Specifications
When evaluating a component like it, technical specifications are paramount. Here’s a closer look at its key features:
Dimensions and Weight
- Dimensions: Compact yet powerful, fitting seamlessly into various setups.
- Weight: Lightweight design for easy handling and installation.
Electrical Specifications
- Voltage Range: Operates efficiently across a wide voltage range.
- Power Consumption: Optimized for minimal power consumption without compromising performance.
Environmental Ratings
- Temperature Range: Designed to operate in extreme temperatures.
- Humidity Resistance: Built to withstand high humidity environments.
Applications of Schneider C11H6TM050L
The versatility of it is one of its standout features. Here’s where you can expect to see it in action:
Industrial Applications
Used in manufacturing plants to control and monitor machinery, ensuring smooth and efficient production processes.
Commercial Uses
Ideal for building management systems, enhancing the automation of lighting, HVAC, and security systems in commercial buildings.
Home Automation
A critical component in smart home systems, controlling various functions from lighting to security.
Benefits of Using Schneider C11H6TM050L
Why should you opt for it? Here are some compelling reasons:
Efficiency
Maximizes operational efficiency, reducing downtime and enhancing productivity.
Reliability
Built to last, offering consistent performance even in demanding conditions.
Cost-Effectiveness
Offers a high return on investment by lowering maintenance costs and energy consumption.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63H |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 50 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | H 70 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 4.81 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 12 module |
| Trip unit rating | 50 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 600 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 108 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.42 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.000 cm |
| Package 1 Width | 12.000 cm |
| Package 1 Length | 22.000 cm |
| Package 1 Weight | 1.600 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 10.190 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 144 |
| Package 3 Height | 150.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 254.490 kg |
Reviews
There are no reviews yet.