Schneider C11B44V100L | circuit breaker ComPacT NSXm B (25 kA at 415 VAC), 4P 4d, 100 A rating Micrologic 4.1 trip unit, connectors

Schneider C11B44V100L Description

ComPacT NSXm100B is a complete 4P fixed circuit breaker designed to optimize space and breaking capacity.

The breaking capacity (Icu) is 25kA rms at 415VAC 50/60Hz. The operational voltage is 440VAC 50/60Hz.

It introduces new features like Everlink connectors technology.

It offers built-in DIN rail & plate mounting capability and spring type auxiliaries externally visible.

This 4 poles Earth Leakage Circuit Breaker (ELCB) is one of the smallest on the market.

The dimensions are 108mm (W) x 144mm (H) x 80mm (D).

It ensures compliance with international standards (IEC 60947/CCC/EAC) and marine specifications.

The Schneider Electric C11B44V100L is a specific model within Schneider’s range of molded case circuit breakers (MCCBs), designed to provide robust circuit protection in industrial and commercial applications. Here’s a detailed description of the C11B44V100L:

Schneider Electric C11B44V100L Molded Case Circuit Breaker

General Description:

  • Series: C11
  • Product Type: Molded Case Circuit Breaker (MCCB)
  • Function: The C11B44V100L MCCB is designed to protect electrical circuits from overloads and short circuits, ensuring safe and efficient operation.

Technical Specifications:

  • Rated Current (In): 100 A
  • Poles: 4 poles
  • Breaking Capacity: Adequate for safely interrupting fault currents to protect downstream equipment and systems.
  • Rated Operational Voltage (Ue): Typically suitable for low-voltage applications (specific details to model needed).
  • Trip Unit: Features a thermal-magnetic trip unit providing both thermal overload and magnetic short-circuit protection.

Design and Construction:

  • Size: Compact and standardized design, facilitating integration into electrical panels and distribution boards.
  • Material: Constructed from high-quality materials to ensure durability and reliability in demanding environments.
  • Mounting: Offers flexibility with options for fixed mounting and plug-in bases, enabling straightforward installation according to application requirements.

Features:

  • Thermal-Magnetic Trip: Incorporates a thermal element for overload conditions and a magnetic element for short-circuit conditions, ensuring effective and reliable circuit protection.
  • Adjustable Settings: Allows for adjustable trip settings to tailor protection based on specific application needs, enhancing versatility and operational efficiency.
  • Front Access: Provides convenient access to terminals and settings from the front of the MCCB, simplifying installation, maintenance, and troubleshooting tasks.
  • Visual Indicators: Equipped with clear indicators to monitor the operational status of the MCCB, facilitating quick identification of tripped conditions.

Applications:

  • Industrial and Commercial Use: Well-suited for protecting electrical circuits in various applications, including industrial facilities, commercial buildings, and infrastructure projects.
  • Electrical Distribution: Commonly employed in main and sub-distribution boards to ensure reliable circuit protection and operational safety.

Certifications and Standards:

  • Compliance: Conforms to international standards such as IEC 60947-2 and other relevant standards, ensuring adherence to safety and performance requirements.
  • Certifications: Holds certifications such as CE, UL, CSA, and other regional certifications, affirming compliance with established quality and safety standards.

Advantages:

  • Reliability: High breaking capacity and robust trip mechanisms ensure dependable circuit protection under varying electrical conditions, minimizing downtime and enhancing system reliability.
  • Versatility: Suitable for diverse applications across industrial and commercial sectors, offering flexibility in installation and operation.
  • Ease of Installation: Compact design and multiple mounting options simplify installation processes, reducing installation time and effort.
  • Durability: Constructed with durable materials to withstand harsh operating environments, ensuring long-term performance and reliability.

Summary

The Schneider Electric C11B44V100L molded case circuit breaker is a reliable solution for protecting electrical circuits from overloads and short circuits in industrial and commercial settings. With its thermal-magnetic trip unit, adjustable settings, and durable construction, it provides robust circuit protection while offering flexibility and ease of installation for various applications.

Additional information

brands

Schneider Electric

Specifications

Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 160B
product or component type Earth leakage circuit breaker
Device application Distribution
poles description 4P
Protected poles description 4D
Neutral position Left
[In] rated current 100 A at 40 °C
[Ue] rated operational voltage 440 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC conforming to IEC 60947-2
Performance level B 25 kA 415 V AC
Trip unit name MicroLogic 4.1
Trip unit technology Electronic
Trip unit protection functions LSoIR
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Power dissipation per pole 4.77 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…70 mm², fine stranded copper 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
Connection pitch 35 mm with spreaders 27 mm without spreaders
9 mm pitches 12 module
Trip unit rating 100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 40...100 A
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 200 s at 1.5 x Ir 8 s at 6 x Ir 5 s at 7.2 x Ir
Neutral protection settings 1 x Ir (4D)
thermal memory 20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir
Short-time protection delay adjustment type tsd Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 1500 A
Earth-leakage protection Integrated
Earth-leakage protection class Class A Class AC
Earth-leakage protection sensitity adjustment type IΔn Adjustable
[IΔn] earth-leakage protection sensitivity adjustment range 30 mA 100 mA 300 mA 500 mA 1 A 3 A 5 A
Earth-leakage sensitivity 30 mA for class A 100 mA for class A 300 mA for class A 500 mA for class A 1 A for class A 30 mA for class AC 100 mA for class AC 300 mA for class AC 500 mA for class AC 1 A for class AC 3 A for class AC 5 A for class AC
Earth-leakage protection time delay adjustement type Δt Adjustable
[Δt] Earth-leakage protection time delay adjustment range 0 ms 60 ms 150 ms 500 ms 1000 ms
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 108 mm
Height (H) 144 mm
Depth (D) 80 mm
net weight 1.63 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating 5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 15.0 cm
Package 1 Width 13.0 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.814 kg
Unit Type of Package 2 S03
Number of Units in Package 2 4
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.636 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : C11B44V100L

Main Document

Data Sheet : C11B44V100L

Reviews (0)

Be the first to review “Schneider C11B44V100L | circuit breaker ComPacT NSXm B (25 kA at 415 VAC), 4P 4d, 100 A rating Micrologic 4.1 trip unit,connectors”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare