Schneider C11B6TM063B | Circuit breaker, ComPacT NSXm 63B, 25kA/415VAC, 4 poles 3D, TMD trip unit 63A, lugs/busbars
Description
Schneider C11B6TM063B | Circuit breaker, ComPacT NSXm 63B, 25kA/415VAC, 4 poles 3D, TMD trip unit 63A, lugs/busbars
Schneider C11B6TM063B Description
Introduction
Circuit breakers are essential for protecting electrical systems from damage caused by overloads and short circuits. Among the top manufacturers, Schneider Electric is renowned for its innovative and reliable products. In this article, we will explore the Schneider C11B6TM063B, a popular choice for a wide range of applications.
What is the Schneider C11B6TM063B?
The Schneider C11B6TM063B is a high-quality circuit breaker designed to provide excellent protection for electrical circuits. Known for its robustness and reliability, this model is a preferred choice for many.
Product Introduction
The C11B6TM063B is part of Schneider Electric’s extensive range of circuit breakers. It is designed to ensure safety and efficiency in electrical systems.
Key Features
- Rated voltage: 230/400V
- Current rating: 6A
- Breaking capacity: 10kA
- Tripping curve: Type B
Technical Specifications
Voltage and Current Ratings
This model operates efficiently within a voltage range of 230/400V and has a current rating of 6A, making it suitable for a variety of applications.
Dimensions and Weight
Compact and lightweight, the C11B6TM063B is designed to fit easily into electrical panels without taking up much space.
Operating Temperature Range
It functions optimally within a temperature range of -5°C to +40°C, ensuring reliability in various environmental conditions.
Design and Construction
Material Quality
The C11B6TM063B is constructed with high-quality materials that enhance its durability and longevity.
Build Durability
Its robust design ensures that it can withstand harsh conditions, providing reliable protection over time.
Functionality and Performance
Overload Protection
This circuit breaker efficiently prevents overloads, protecting your electrical circuits from potential damage.
Short Circuit Protection
It also offers reliable short circuit protection, ensuring the safety of your electrical system.
Tripping Mechanism
The C11B6TM063B features a precise tripping mechanism that quickly responds to faults, enhancing safety.
Installation Process
Step-by-Step Guide
- Turn off the main power supply.
- Mount the circuit breaker onto the DIN rail.
- Connect the input and output wires to the breaker terminals.
- Secure the connections and check for any loose wires.
- Turn on the main power supply and test the circuit breaker.
Safety Precautions
Always follow safety guidelines and use appropriate protective equipment when installing electrical components.
Longevity
Durable construction and high-quality materials guarantee a long service life.
Comparing Schneider C11B6TM063B with Other Models
Similar Products from Schneider
Other models like the C11B6TM100 offer higher current ratings, suitable for different needs.
Competitor Products
Comparing with brands like Siemens and ABB, Schneider offers superior build quality and performance.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63B |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 63 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | B 25 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 50 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 5.58 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Compression lug/busbar |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 12 module |
| Trip unit rating | 63 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 800 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 108 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.42 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12 cm |
| Package 1 Width | 13 cm |
| Package 1 Length | 22 cm |
| Package 1 Weight | 1.6 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 10.19 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 144 |
| Package 3 Height | 150 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 254.49 kg |