Schneider C11N3TM025L | Circuit breaker, ComPacT NSXm 63N, 50kA/415VAC, 3 poles, TMD trip unit 25A, EverLink lugs
Schneider C11N3TM025L | Circuit breaker, ComPacT NSXm 63N, 50kA/415VAC, 3 poles, TMD trip unit 25A, EverLink lugs
Description
Schneider C11N3TM025L: A Detailed Overview
Introduction
The Schneider C11N3TM025L is a notable component in Schneider Electric’s lineup, known for its reliability and performance in electrical systems. This article provides a comprehensive guide to understanding its features, applications, and benefits.
Overview of Schneider Electric
Company History
Schneider Electric has a rich history spanning over a century, specializing in energy management and automation solutions. The company is renowned for its commitment to innovation and sustainability.
Commitment to Quality
Schneider Electric emphasizes quality in all its products, ensuring they meet rigorous standards for performance, safety, and efficiency.
Key Features of Schneider C11N3TM025L
High Performance
The Schneider C11N3TM025L is designed for high-performance applications, offering reliable operation under various conditions.
Durability
Built with durable materials, this component withstands wear and tear, ensuring longevity and minimal maintenance requirements.
Safety Features
Safety is paramount in electrical components. The C11N3TM025L includes advanced safety features to protect against electrical hazards.
Technical Specifications
Voltage and Current Ratings
Operates at a voltage rating of [insert specific voltage rating] and handles current up to [insert specific current rating], making it suitable for diverse electrical setups.
Physical Dimensions
Compact design facilitates easy installation in electrical panels with minimal space requirements.
Installation Requirements
Simple installation process requires basic tools and adherence to safety protocols for optimal performance.
Applications of Schneider C11N3TM025L
Industrial Uses
Ideal for industrial environments requiring robust electrical components for efficient power management.
Commercial Buildings
Used in commercial settings to ensure reliable power distribution and energy efficiency.
Residential Settings
Suitable for residential applications where reliable electrical performance is essential.
Benefits of Using Schneider C11N3TM025L
Enhanced Efficiency
Improves energy efficiency, reducing operational costs and environmental impact.
Reliability
Consistent performance ensures uninterrupted power supply, critical for industrial and commercial operations.
Cost-Effectiveness
Long-term savings through reduced energy consumption and maintenance costs.
Installation Process
Step-by-Step Guide
- Preparation: Gather necessary tools and review installation instructions.
- Safety: Disconnect power source and follow safety guidelines.
- Mounting: Secure the C11N3TM025L in designated panel space.
- Wiring: Connect according to manufacturer guidelines, ensuring proper insulation.
- Testing: Verify functionality before restoring power.
Maintenance Tips
Regular inspections and cleaning ensure optimal performance and longevity.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63N |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 25 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | N 50 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 2.83 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Trip unit rating | 25 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 600 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.06 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.2 cm |
| Package 1 Width | 9.0 cm |
| Package 1 Length | 21.4 cm |
| Package 1 Weight | 1.204 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 11.214 kg |