Schneider A9K24210 | Miniature circuit-breaker, Acti9 iK60N, 2P, 10 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24210 | Miniature circuit-breaker, Acti9 iK60N, 2P, 10 A, C curve, 6000 A (IEC 60898-1)
Description
Schneider A9K24210: A Comprehensive Guide
Introduction
What is Schneider A9K24210? it is a top-of-the-line circuit breaker designed to ensure optimal protection and efficiency in various electrical systems. It plays a crucial role in maintaining safety and reliability, preventing electrical hazards.
Importance in Electrical Systems. Circuit breakers like it are vital in safeguarding electrical circuits from overloads and short circuits. They ensure the smooth operation of electrical systems, protecting appliances and infrastructure from damage.
Understanding the Schneider A9K24210
Overview and Specifications
it is part of Schneider Electric’s renowned Acti9 series, known for its advanced features and robust performance. It is a 2-pole circuit breaker with a breaking capacity of 10 kA, making it suitable for a wide range of applications.
Key Features
- High Breaking Capacity: With a 10 kA capacity, it can handle substantial electrical loads.
- Compact Design: Easily fits into various electrical panels.
- Reliable Performance: Ensures consistent safety and efficiency.
- Energy Efficient: Designed to reduce energy consumption.
Applications of Schneider A9K24210
Residential Use
In homes, it offers essential protection for electrical systems, ensuring the safety of household appliances and electronic devices.
Commercial Use
For commercial buildings, it ensures that critical systems like lighting, HVAC, and security systems operate without interruption due to electrical issues.
Industrial Use
In industrial environments, where electrical loads are significantly higher, it provides robust protection, maintaining operational efficiency and safety.
Installation of Schneider A9K24210
Pre-Installation Requirements
- Ensure Compatibility: Verify that it is suitable for your electrical system.
- Gather Tools and Equipment: Necessary tools include screwdrivers, wire strippers, and multimeters.
Step-by-Step Installation Guide
- Turn Off Power: Ensure the main power supply is switched off to avoid electrical shocks.
- Mount the Breaker: Securely mount the Schneider A9K24210 in the designated slot in the electrical panel.
- Connect Wires: Connect the input and output wires to the respective terminals on the breaker.
- Test the Installation: After installation, turn on the power and test the breaker to ensure it operates correctly.
Safety Precautions
- Always follow manufacturer instructions.
- Wear protective gear such as gloves and safety goggles.
- If unsure, consult a professional electrician.
Advantages of Using Schneider A9K24210
Durability and Reliability
it is built to last, using high-quality materials that ensure it performs reliably over time.
Energy Efficiency
This breaker is designed to minimize energy losses, helping to reduce electricity bills.
Cost-Effectiveness
While it may have a higher upfront cost, the long-term savings in energy and maintenance make it a cost-effective choice.
Maintenance and Troubleshooting
Regular Maintenance Tips
- Periodic Inspections: Regularly check for any signs of wear or damage.
- Clean Components: Keep the breaker and surrounding area clean to avoid dust buildup.
- Test Functionality: Periodically test the breaker to ensure it trips correctly.
Common Issues and Solutions
- Breaker Tripping Frequently: Check for overloaded circuits and reduce the load if necessary.
- No Power to Circuit: Ensure all connections are secure and there are no loose wires.
- Physical Damage: Replace the breaker if there are any visible signs of damage.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iK60 |
| product or component type | Miniature circuit-breaker |
| Device short name | iK60N |
| poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 10 A at 30 °C |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| Suitability for isolation | Yes conforming to EN/IEC 60898-1 |
| Standards | EN/IEC 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 5...10 x In |
| [Ics] rated service breaking capacity | 6000 A 100 % conforming to EN/IEC 60898-1 - 230 V AC 50/60 Hz |
| Limitation class | 3 conforming to EN/IEC 60898-1 |
| [Ui] rated insulation voltage | 440 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| [Uimp] rated impulse withstand voltage | 4 kV conforming to EN/IEC 60898-1 |
| Contact position indicator | No |
| Control type | Toggle |
| local signalling | ON/OFF indication |
| mounting mode | Clip-on |
| mounting support | DIN rail |
| 9 mm pitches | 4 |
| Height | 85 mm |
| Width | 36 mm |
| Depth | 78.5 mm |
| net weight | 200 g |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Tunnel type terminal (top or bottom) 1…25 mm² rigid Tunnel type terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Without |
| IP degree of protection | IP20 conforming to IEC 60529 |
|---|---|
| Pollution degree | 2 conforming to EN/IEC 60898-1 |
| Overvoltage category | II |
| Ambient air temperature for operation | -25…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 3.5 cm |
| Package 1 Width | 7.5 cm |
| Package 1 Length | 9.5 cm |
| Package 1 Weight | 194 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 8 cm |
| Package 2 Width | 9.5 cm |
| Package 2 Length | 22 cm |
| Package 2 Weight | 1.215 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 66 |
| Package 3 Height | 30 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 13.79 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider A9K24206 | Miniature circuit-breaker, Acti9 iK60N, 2P, 6 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24220 | Miniature circuit-breaker, Acti9 iK60N, 2P, 20 A, C curve, 6000 A (IEC 60898-1)
-
0
Schneider A9K24216 | Miniature circuit-breaker, Acti9 iK60N, 2P, 16 A, C curve, 6000 A (IEC 60898-1)
Schneider A9K24320 | miniature circuit breaker – iK60N – 3P – 20 A – C curve
-
0
Schneider A9K24263 | Miniature circuit-breaker, Acti9 iK60N, 2P, 63 A, C curve, 6000 A (IEC 60898-1)
-
0
Reviews
There are no reviews yet.