Schneider C10N3TM063 | Circuit breaker ComPacT NSX100N, 50kA at 415VAC, TMD trip unit 63A, 3 poles 3d
Description
Schneider C10N3TM063 | Circuit breaker ComPacT NSX100N, 50kA at 415VAC, TMD trip unit 63A, 3 poles 3d
Introduction to Schneider C10N3TM063
In the realm of industrial automation and motor protection, the Schneider C10N3TM063 is a noteworthy component. This motor protection circuit breaker is engineered to deliver optimal protection and control for electrical motors. Renowned for its advanced features and reliable performance, it is a preferred choice among industry professionals, making it a crucial player in the market.
Technical Specifications
The Schneider C10N3TM063 is packed with impressive technical specifications. It supports a wide range of operating voltages and features an adjustable thermal overload setting from 1 to 63 amperes. This range allows for precise protection tailored to various motor ratings. It also boasts a short-circuit breaking capacity of 50 kA at 400V, ensuring robust protection in high-risk situations. The device’s compact design, with a width of 45mm, facilitates easy installation even in confined spaces.
Features and Benefits
This motor protection circuit breaker comes with a plethora of features designed to enhance functionality and user experience. The integrated thermal-magnetic trip unit ensures reliable protection against overloads and short circuits. The ergonomic rotary handle simplifies operation, while the visual indicators provide clear, real-time status updates, making monitoring and maintenance straightforward. These features collectively ensure that the Schneider C10N3TM063 not only protects motors but also streamlines their management.
Applications of Schneider C10N3TM063
The Schneider C10N3TM063 is highly versatile and finds applications across various sectors. In industrial settings, it is essential for protecting and controlling motors in manufacturing plants, ensuring safe and efficient operations. Commercially, it is used in HVAC systems, elevators, and other motor-driven equipment, providing consistent protection and minimizing downtime. In residential contexts, it can be integrated into smart home systems to safeguard motor-driven appliances, ensuring their longevity and optimal performance.
Installation and Setup
Installing the Schneider C10N3TM063 is a straightforward process, though it requires careful attention to detail. Before installation, it’s crucial to verify the compatibility of the device with the motor and electrical system. The installation involves mounting the circuit breaker onto a DIN rail, connecting the incoming and outgoing power lines, and setting the thermal overload adjustment according to the motor’s specifications. Common issues such as improper connections or incorrect settings can usually be resolved by consulting the comprehensive user manual or contacting Schneider’s technical support.
User Interface and Controls
The user interface of the Schneider C10N3TM063 is designed for ease of use. The rotary handle is ergonomically designed, facilitating easy operation. The visual indicators provide clear, real-time status updates, allowing users to quickly assess and manage the device’s operation. This intuitive interface ensures that even first-time users can operate the device efficiently.
Performance and Efficiency
The performance of the Schneider C10N3TM063 is exemplary. It delivers consistent protection across various load conditions, thanks to its precise thermal-magnetic trip unit. The device’s high breaking capacity ensures it can handle short-circuit events without compromising safety or performance. Additionally, its energy-efficient design helps in reducing overall power consumption, contributing to cost savings and environmental sustainability.
Future of Schneider C10N3TM063
Looking ahead, the Schneider C10N3TM063 is poised to evolve with new features and updates. Schneider is committed to continuous improvement, regularly releasing firmware updates and new accessories to enhance the functionality of their devices. Additionally, market trends indicate a growing demand for smart and connected motor protection solutions, positioning the C10N3TM063 at the forefront of innovation in this field.
Environmental Impact
The Schneider C10N3TM063 is designed with environmental sustainability in mind. Its energy-efficient design reduces power consumption, while its robust construction ensures longevity, minimizing waste. The device also complies with various environmental standards, making it a responsible choice for eco-conscious users.
Safety Features
Safety is a paramount consideration for any electrical device, and the Schneider C10N3TM063 excels in this area. It includes built-in safety mechanisms such as thermal and magnetic trip units, which provide reliable protection against overloads and short circuits. Additionally, the device features clear visual indicators and an ergonomic rotary handle, ensuring safe and easy operation.
Conclusion
In summary, the Schneider C10N3TM063 stands out as a highly reliable and versatile motor protection circuit breaker. Its advanced features, robust performance, and user-friendly design make it a top choice for various applications, from industrial to residential. Whether you’re looking to enhance the safety and efficiency of your operations or seeking a dependable solution for motor protection, the Schneider C10N3TM063 offers excellent value and performance.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX100N |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 63 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | N 50 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Power dissipation per pole | 8.61 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 63 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 500 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 105 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| net weight | 2.05 kg |
| Standards | EN/IEC 60947 |
|---|---|
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 11.2 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 1.778 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 7 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 12.828 kg |