In the realm of industrial automation and motor protection, the Schneider C10N3TM063 is a noteworthy component. This motor protection circuit breaker is engineered to deliver optimal protection and control for electrical motors. Renowned for its advanced features and reliable performance, it is a preferred choice among industry professionals, making it a crucial player in the market.

Technical Specifications

The Schneider C10N3TM063 is packed with impressive technical specifications. It supports a wide range of operating voltages and features an adjustable thermal overload setting from 1 to 63 amperes. This range allows for precise protection tailored to various motor ratings. It also boasts a short-circuit breaking capacity of 50 kA at 400V, ensuring robust protection in high-risk situations. The device’s compact design, with a width of 45mm, facilitates easy installation even in confined spaces.

Features and Benefits

This motor protection circuit breaker comes with a plethora of features designed to enhance functionality and user experience. The integrated thermal-magnetic trip unit ensures reliable protection against overloads and short circuits. The ergonomic rotary handle simplifies operation, while the visual indicators provide clear, real-time status updates, making monitoring and maintenance straightforward. These features collectively ensure that the Schneider C10N3TM063 not only protects motors but also streamlines their management.

Applications of Schneider C10N3TM063

The Schneider C10N3TM063 is highly versatile and finds applications across various sectors. In industrial settings, it is essential for protecting and controlling motors in manufacturing plants, ensuring safe and efficient operations. Commercially, it is used in HVAC systems, elevators, and other motor-driven equipment, providing consistent protection and minimizing downtime. In residential contexts, it can be integrated into smart home systems to safeguard motor-driven appliances, ensuring their longevity and optimal performance.

Installation and Setup

Installing the Schneider C10N3TM063 is a straightforward process, though it requires careful attention to detail. Before installation, it’s crucial to verify the compatibility of the device with the motor and electrical system. The installation involves mounting the circuit breaker onto a DIN rail, connecting the incoming and outgoing power lines, and setting the thermal overload adjustment according to the motor’s specifications. Common issues such as improper connections or incorrect settings can usually be resolved by consulting the comprehensive user manual or contacting Schneider’s technical support.

User Interface and Controls

The user interface of the Schneider C10N3TM063 is designed for ease of use. The rotary handle is ergonomically designed, facilitating easy operation. The visual indicators provide clear, real-time status updates, allowing users to quickly assess and manage the device’s operation. This intuitive interface ensures that even first-time users can operate the device efficiently.

Performance and Efficiency

The performance of the Schneider C10N3TM063 is exemplary. It delivers consistent protection across various load conditions, thanks to its precise thermal-magnetic trip unit. The device’s high breaking capacity ensures it can handle short-circuit events without compromising safety or performance. Additionally, its energy-efficient design helps in reducing overall power consumption, contributing to cost savings and environmental sustainability.

Future of Schneider C10N3TM063

Looking ahead, the Schneider C10N3TM063 is poised to evolve with new features and updates. Schneider is committed to continuous improvement, regularly releasing firmware updates and new accessories to enhance the functionality of their devices. Additionally, market trends indicate a growing demand for smart and connected motor protection solutions, positioning the C10N3TM063 at the forefront of innovation in this field.

Environmental Impact

The Schneider C10N3TM063 is designed with environmental sustainability in mind. Its energy-efficient design reduces power consumption, while its robust construction ensures longevity, minimizing waste. The device also complies with various environmental standards, making it a responsible choice for eco-conscious users.

Safety Features

Safety is a paramount consideration for any electrical device, and the Schneider C10N3TM063 excels in this area. It includes built-in safety mechanisms such as thermal and magnetic trip units, which provide reliable protection against overloads and short circuits. Additionally, the device features clear visual indicators and an ergonomic rotary handle, ensuring safe and easy operation.

Conclusion

In summary, the Schneider C10N3TM063 stands out as a highly reliable and versatile motor protection circuit breaker. Its advanced features, robust performance, and user-friendly design make it a top choice for various applications, from industrial to residential. Whether you’re looking to enhance the safety and efficiency of your operations or seeking a dependable solution for motor protection, the Schneider C10N3TM063 offers excellent value and performance.

Additional information

brands

Schneider Electric

Specifications

Main
Range ComPacT new generation
Product name ComPacT NSX new generation
Device short name NSX100N
product or component type Circuit breaker
Device application Distribution
poles description 3P
Protected poles description 3D
[In] rated current 63 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level N 50 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 50000 cycles
Electrical durability 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Power dissipation per pole 8.61 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal) I : for short-circuit protection (magnetic)
Trip unit rating 63 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
[tr] long-time protection delay adjustment range 120…400 s at 1.5 x In 15 s at 6 x Ir
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 500 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 5 slot(s)
Width (W) 105 mm
Height (H) 161 mm
Depth (D) 86 mm
net weight 2.05 kg
Environment
Standards EN/IEC 60947
Product certifications CCC EAC Marine
Overvoltage category Class II
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating 2000 m...5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.0 cm
Package 1 Width 11.2 cm
Package 1 Length 19.0 cm
Package 1 Weight 1.778 kg
Unit Type of Package 2 S03
Number of Units in Package 2 7
Package 2 Height 30.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 12.828 kg

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider C10N3TM063 | Circuit breaker ComPacT NSX100N, 50kA at 415VAC, TMD trip unit 63A, 3 poles 3d”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare