Schneider A9R10225 | Acti 9 iID – RCCB – 2P – 25A – 10mA – type AC
Schneider A9R10225 | Acti 9 iID – RCCB – 2P – 25A – 10mA – type AC
Description
Schneider A9R10225 | Acti 9 iID – RCCB – 2P – 25A – 10mA – type AC
. Technical Specifications A9R10225
-
Brand: Schneider Electric
-
Series: Acti9 iID
-
Model Number: A9R10225
-
Device Type: RCCB (Residual Current Circuit Breaker)
-
Number of Poles: 2 Poles
-
Rated Current (In): 25 Amperes
-
Rated Residual Operating Current (IΔn): 10 mA
-
Sensitivity Type: Type AC (detects pure sinusoidal AC leakage currents)
-
Rated Voltage (Ue): 230/240V AC (single-phase)
-
Frequency: 50/60 Hz
-
Short-Circuit Withstand Capacity: 6 kA (when used with appropriate backup protection)
-
Mounting: DIN rail, 2 modules width (36 mm)
-
Degree of Protection: IP20 (front panel), IP40 (in enclosure)
-
Operating Temperature: -25°C to +60°C
-
Standards: IEC/EN 61008-1 compliant
. Key Features
-
High Sensitivity (10 mA): Provides enhanced protection against electrical shock and is suitable for personal safety applications.
-
Type AC Detection: Detects AC earth leakage currents (suitable for general-purpose use in typical residential and light commercial installations).
-
Full Pole Disconnection: Disconnects both live and neutral, ensuring maximum safety.
-
Compact Design: Takes up only 2 DIN rail modules (36 mm), ideal for compact distribution boards.
-
Status Indicator: Clear mechanical toggle and trip indicator for quick fault identification.
-
Reliable Mechanism: Proven Schneider technology ensures consistent performance and long-term reliability.
-
Double Insulated Housing: Enhances electrical safety during handling and installation.
-
Tool-Free Mounting: Quick to install on standard DIN rails without the need for special tools.
-
Test Button: Built-in test function allows for periodic checking of proper functionality.
. Applications
The Schneider A9R10225 RCCB is particularly suitable for applications that demand very high safety standards and low leakage current protection:
-
Residential Installations: Bathrooms, kitchens, or bedrooms to protect people from electrical shock.
-
Healthcare Facilities: Clinics, hospitals, or patient rooms where sensitive residual current protection is critical.
-
Public Buildings: Schools, offices, hotels, and other public access areas.
-
Special Equipment Protection: Where even small leakage currents (under 10mA) could pose a safety risk.
-
Wet Areas and Outdoor Circuits: Such as water heaters, pools, or garden installations.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Acti9 |
|---|---|
| Product name | Acti9 iID |
| Product or component type | Residual current circuit breaker (RCCB) |
| Device short name | iID |
| Poles description | 2P |
| Neutral position | Left |
| [In] rated current | 25 A |
| Network type | AC |
| Earth-leakage sensitivity | 10 mA |
| earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type AC |
| device location in system | Outgoer |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 220...240 V AC 50/60 Hz |
| Residual current tripping technology | Voltage independent |
| Rated breaking and making capacity | Idm 1500 A Im 1500 A |
| Rated conditional short-circuit current | 10 kA |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Contact position indicator | Yes |
| control type | Toggle |
| Mounting mode | Clip-on |
| mounting support | DIN rail |
| 9 mm pitches | 4 |
| height | 91 mm |
| Width | 36 mm |
| Depth | 73.5 mm |
| Net weight | 0.21 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | AC-1: 15000 cycles |
| Locking options description | Padlocking device |
| Connections - terminals | Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 3.5 N.m top or bottom |
| Standards | EN/IEC 61008-1 |
|---|---|
| Product certifications | EAC |
| IP degree of protection | IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529 |
| Pollution degree | 3 |
| Electromagnetic compatibility | 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1 |
| Ambient air temperature for operation | -5…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.200 cm |
| Package 1 Width | 9.500 cm |
| Package 1 Length | 10.000 cm |
| Package 1 Weight | 221.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 54 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 12.500 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Recommended for you
Schneider A9N61515 | miniature circuit breaker – C60H – 1 pole – 32 A – C curve
Schneider A9N61502 | miniature circuit breaker – C60H – 1 pole – 2 A – C curve
-
0
Schneider A9N26924 | Acti9 – Auxiliary contact OC plus 1 SD and OF ac dc
-
0
Schneider A9N18363 | Miniature circuit-breaker, Acti9 C120N, 2P, 125 A, C curve, 10000 A (IEC 60898-1), 10 kA (IEC 60947-2)
-
0
Schneider A9L40101 | iPRD40r modular surge arrester – 1P – 350V – with remote transfert
-
0