Schneider ATS01N222QN | Soft starter for asynchronous motor, Altistart 01, ATS01, 22A, 380 to 415V, 7.5 to 11kW
Description
Schneider ATS01N222QN | Soft starter for asynchronous motor, Altistart 01, ATS01, 22A, 380 to 415V, 7.5 to 11kW
Schneider ATS01N222QN | Soft Starter Overview
The Schneider ATS01N222QN is a soft starter from the Altistart 01 series, designed to ensure smooth motor acceleration by limiting inrush current and reducing mechanical stress. This enhances motor longevity and improves system efficiency, making it ideal for small to medium-sized industrial applications.
1. General Specifications
-
Product Name: Schneider ATS01N222QN
-
Series: Altistart 01 (ATS01)
-
Type: Soft Starter for Asynchronous Motors
-
Rated Current: 22A
-
Power Rating: 7.5 to 11 kW
-
Operating Voltage: 380V to 415V AC
-
Control Type: Voltage Ramp
-
Motor Compatibility: Three-phase asynchronous motors
2. Key Features & Benefits
-
Smooth Motor Start & Stop – Reduces mechanical and electrical stress.
-
Compact & Cost-Effective Design – Ideal for space-limited control panels.
-
Energy Efficiency – Minimizes power surges and improves performance.
-
Built-in Motor Protection – Guards against overload and overheating.
-
Easy Installation & Setup – Quick wiring with user-friendly configuration.
3. Applications
-
Pumps & Compressors – Prevents pressure surges and extends equipment life.
-
Fans & Blowers – Ensures gradual speed changes for smooth airflow.
-
Conveyor Systems – Facilitates controlled acceleration and deceleration.
-
Industrial Machines – Suitable for small and medium motor-driven applications.
4. Protection & Safety Features
-
Overload & Overtemperature Protection – Prevents motor damage.
-
Voltage Ramp Control – Ensures steady and reliable startup.
-
Phase Loss Detection – Enhances system safety and performance.
-
Built-in Diagnostics & Alerts – Simplifies maintenance and troubleshooting.
5. Installation & Maintenance
-
DIN Rail or Panel Mounting – Flexible installation options.
-
Plug & Play Configuration – No complex programming required.
-
Low Maintenance Design – Reliable for long-term industrial use.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Altistart 01 |
|---|---|
| Product or component type | Soft starter |
| Product destination | Asynchronous motors |
| Product specific application | Simple machine |
| Device short name | ATS01 |
| Network number of phases | 3 phases |
| [Us] rated supply voltage | 380...415 V - 10...10 % |
| Motor power kW | 11 kW, 3 phases at 380...415 V 7.5 kW, 3 phases at 380...415 V |
| IcL starter rating | 22 A |
| Utilisation category | AC-53B conforming to EN/IEC 60947-4-2 |
| Current consumption | 110 A at nominal load |
| Type of start | Start with voltage ramp |
| Power dissipation in W | 124.5 W in transient state 4.5 W at full load and at end of starting |
| Assembly style | With heat sink |
|---|---|
| Function available | Integrated bypass |
| Supply voltage limits | 342…456 V |
| Supply frequency | 50...60 Hz - 5...5 % |
| Network frequency | 47.5...63 Hz |
| Output voltage | <= power supply voltage |
| [Uc] control circuit voltage | Built into the starter |
| Starting time | 1 s / 100 5 s / 20 10 s / 10 Adjustable from 1 to 10 s |
| Deceleration time symb | Adjustable from 1 to 10 s |
| Starting torque | 30...80 % of starting torque of motor connected directly on the line supply |
| Discrete input type | Logic (LI1, LI2, BOOST) stop, run and boost on start-up functions <= 8 mA 27 kOhm |
| Discrete input voltage | 24...40 V |
| Discrete input logic | Positive LI1, LI2, BOOST at State 0: < 5 V and <= 0.2 mA at State 1: > 13 V, >= 0.5 mA |
| Discrete output current | 2 A DC-13 3 A AC-15 |
| Discrete output type | Open collector logic LO1 end of starting signal Relay outputs R1A, R1C NO |
| Discrete output voltage | 24 V (voltage limits: 6...30 V) open collector logic |
| Minimum switching current | 10 mA at 6 V DC for relay outputs |
| Maximum switching current | Relay outputs: 2 A at 250 V AC cos phi = 0.5 and L/R = 20 ms inductive load Relay outputs: 2 A at 30 kV DC cos phi = 0.5 and L/R = 20 ms inductive load |
| Display type | 1 LED (green) for starter powered up 1 LED (yellow) for nominal voltage reached |
| Tightening torque | 0.5 N.m 1.9…2.5 N.m |
| Electrical connection | 4 mm screw clamp terminal - rigid 1 1...10 mm² AWG 8 power circuit Screw connector - rigid without cable end 1 0.5...2.5 mm² AWG 14 control circuit 4 mm screw clamp terminal - rigid 2 1...6 mm² AWG 10 power circuit Screw connector - rigid 2 0.5...1 mm² AWG 17 control circuit Screw connector - flexible with cable end 1 0.5...1.5 mm² AWG 16 control circuit 4 mm screw clamp terminal - flexible without cable end 1 1.5...10 mm² AWG 8 power circuit Screw connector - flexible without cable end 1 0.5...2.5 mm² AWG 14 control circuit 4 mm screw clamp terminal - flexible with cable end 2 1...6 mm² AWG 10 power circuit 4 mm screw clamp terminal - flexible without cable end 2 1.5...6 mm² AWG 10 power circuit Screw connector - flexible without cable end 2 0.5...1.5 mm² AWG 16 control circuit |
| Marking | CE |
| Operating position | Vertical +/- 10 degree |
| Height | 154 mm |
| Width | 45 mm |
| Depth | 131 mm |
| Net weight | 0.56 kg |
| Compatibility code | ATS01N2 |
| Motor power range AC-3 | 7…11 kW at 380…440 V 3 phases |
| Motor starter type | Soft starter |
| Electromagnetic compatibility | Conducted and radiated emissions level B conforming to CISPR 11 Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 EMC immunity level 3 conforming to EN 50082-1 EMC immunity level B conforming to EN 50082-2 Harmonics level 3 conforming to IEC 1000-3-2 Harmonics level 3 conforming to IEC 1000-3-4 Immunity to conducted interference caused by radio-electrical fields level 3 conforming to IEC 61000-4-6 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Micro-cuts and voltage fluctuation conforming to IEC 61000-4-11 Voltage/current impulse level 3 conforming to IEC 61000-4-5 |
|---|---|
| Standards | EN/IEC 60947-4-2 |
| Product certifications | CSA UL CCC C-Tick GOST |
| IP degree of protection | IP20 |
| Pollution degree | 2 conforming to EN/IEC 60947-4-2 |
| Vibration resistance | 1 gn (f= 13…150 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
| Relative humidity | 5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 |
| Ambient air temperature for operation | -10…40 °C (without derating) 40…50 °C (with current derating of 2 % per °C) |
| Ambient air temperature for storage | -25…70 °C conforming to EN/IEC 60947-4-2 |
| Operating altitude | <= 1000 m without derating > 1000 m with current derating of 2.2 % per additional 100 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 17.500 cm |
| Package 1 Length | 15.200 cm |
| Package 1 Weight | 664.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 14 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 10.060 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 112 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 90.588 kg |
| Warranty | 18 months |
|---|