Schneider C10F3TM025 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 25A, 3 poles 3d
Description
Schneider C10F3TM025 | Circuit breaker ComPacT NSX100F, 36kA at 415VAC, TMD trip unit 25A, 3 poles 3d
Schneider C10F3TM025 Description
Introduction
Schneider Electric is a global leader in energy management and automation solutions. Among their extensive range of products are high-quality circuit breakers designed to ensure the safety and efficiency of electrical systems. The Schneider C10F3TM025 is a notable example, offering reliable protection and exceptional performance. This article delves into the features, technical specifications, applications, and overall value of the Schneider C10F3TM025.
Overview of the Schneider C10F3TM025
The Schneider C10F3TM025 is a miniature circuit breaker (MCB) engineered to protect electrical circuits from overloads and short circuits. It plays a crucial role in maintaining the safety and reliability of electrical systems.
Basic Description
The Schneider C10F3TM025 is a single-pole, 25A circuit breaker with an F curve characteristic, meaning it trips between 3 to 5 times the rated current. This makes it suitable for protecting circuits with moderate inrush currents.
Key Features
- Single-Pole Protection: Provides effective protection for individual circuits.
- High Breaking Capacity: Can interrupt high fault currents, ensuring system safety.
- Compact Design: Fits easily into standard electrical panels, saving space.
- Durable Construction: Made from high-quality materials for long-lasting performance.
- Easy Installation: User-friendly design for quick and hassle-free installation.
Technical Specifications
Electrical Specifications
- Rated Voltage: 230/400V AC
- Rated Current: 25A
- Breaking Capacity: 10kA according to IEC/EN 60898-1
- Tripping Curve: Type F (3-5 times the rated current)
Mechanical Specifications
- Dimensions: 81mm x 18mm x 70mm
- Weight: 0.150 kg
- Mounting: DIN rail
Design and Build Quality
The Schneider C10F3TM025 is designed for durability and reliability, featuring high-quality materials and precise construction.
Materials Used
- Housing: Fire-resistant plastic ensures safety and durability.
- Internal Components: Constructed from high-grade copper and silver alloy.
- Terminals: Made from corrosion-resistant metals to ensure longevity.
Construction Details
Schneider Electric ensures that each circuit breaker meets high standards of performance and safety through stringent quality control measures. The C10F3TM025 is designed to withstand regular use in demanding environments, providing reliable protection over the long term.
Installation Guidelines
Proper installation is crucial for the effective performance and safety of the Schneider C10F3TM025.
Pre-Installation Checklist
- Verify that the main power supply is turned off.
- Ensure compatibility with the electrical panel.
- Gather necessary tools and protective equipment.
Step-by-Step Installation Process
- Power Down: Turn off the main power supply to avoid electrical hazards.
- Mount the Breaker: Secure the C10F3TM025 to the DIN rail in the electrical panel.
- Wire Connections: Connect the input and output wires to the appropriate terminals, ensuring tight connections.
- Test the Circuit: Restore power and test the breaker to ensure it functions correctly.
- Finalize Installation: Organize and secure any loose wires and close the panel.
Applications and Usage
The versatility of the Schneider C10F3TM025 makes it suitable for various applications.
Industrial Applications
Ideal for protecting motor circuits and transformers in industrial settings.
Commercial Applications
Provides reliable protection for lighting, HVAC systems, and other commercial electrical loads.
Residential Applications
Perfect for household electrical circuits, safeguarding appliances and preventing electrical hazards.
Compatibility and Integration
The Schneider C10F3TM025 is designed to integrate seamlessly with various electrical systems.
Compatible Systems and Devices
- Electrical Panels: Compatible with standard residential, commercial, and industrial electrical panels.
- Automation Systems: Can be integrated with building automation systems for enhanced control and monitoring.
- Renewable Energy Systems: Suitable for use in small-scale solar and wind power installations.
Integration Tips
- Ensure all connections are secure to avoid potential faults.
- Regularly inspect and maintain the circuit breaker to ensure ongoing compatibility and performance.
Performance and Efficiency
The Schneider C10F3TM025 is engineered for high performance and energy efficiency.
Performance Metrics
- Response Time: Quick tripping response to overloads and short circuits.
- Reliability: Consistent protection with minimal downtime.
Energy Efficiency Considerations
The design minimizes energy loss, contributing to the overall efficiency of the electrical system.
Safety Features
Schneider Electric prioritizes safety, and the C10F3TM025 includes several built-in safety features.
Compliance with Safety Standards
The C10F3TM025 complies with international safety standards, including IEC/EN 60898-1, ensuring it meets stringent safety requirements.
Built-In Safety Mechanisms
- Overload Protection: Automatically trips to prevent overheating and potential fires.
- Short Circuit Protection: Quickly isolates faults to prevent damage to the electrical system.
Maintenance and Troubleshooting
Regular maintenance ensures the continued effective operation of the Schneider C10F3TM025.
Customer Support Options
- Technical Support: Available via phone and email for assistance with installation, troubleshooting, and maintenance.
- Online Resources: Access to manuals, FAQs, and video tutorials on the Schneider Electric website.
Pros and Cons
Advantages of the C10F3TM025
- Reliable Protection: Effective protection against overloads and short circuits.
- Durable Construction: High-quality materials ensure longevity and reliability.
- Easy Installation: User-friendly design simplifies the installation process.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX100F |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 25 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In |
| Power dissipation per pole | 4.01 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 25 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 300 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 105 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| net weight | 2.05 kg |
| Standards | EN/IEC 60947 |
|---|---|
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 11.0 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 1.836 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 7 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 13.228 kg |
Reviews
There are no reviews yet.