Schneider C11F3TM080B | Circuit breaker, ComPacT NSXm 160F, 36kA/415VAC, 3 poles, TMD trip unit 80A
Schneider C11F3TM080B | Circuit breaker, ComPacT NSXm 160F, 36kA/415VAC, 3 poles, TMD trip unit 80A
Description
Schneider C11F3TM080B
Schneider Electric is a global leader in energy management and automation. Known for its innovative solutions, the company has a broad portfolio of products designed to improve energy efficiency and sustainability. One of their standout products is the Schneider C11F3TM080B, a device that has garnered attention in various industries for its advanced features and reliability.
Technical Specifications
When it comes to technical specs, it doesn’t disappoint. Here’s a detailed breakdown:
- Voltage Rating: 240V
- Current Rating: 80A
- Frequency: 50/60Hz
- Operating Temperature Range: -25°C to 70°C
- Enclosure Rating: IP65
Compared to similar models, it offers superior performance and reliability, making it a preferred choice for many professionals.
Key Features
Energy Efficiency
One of the primary features of it is its energy efficiency. Designed to minimize energy consumption, it helps in reducing operational costs significantly.
Safety Features
Safety is a top priority, and this model comes equipped with multiple safety features, including overload protection and short circuit prevention, ensuring safe operation in various environments.
Durability and Reliability
Built with high-quality materials, it is known for its durability and long lifespan. It can withstand harsh conditions, making it ideal for both indoor and outdoor applications.
Applications and Use Cases
Industrial Applications
In industrial settings, it is used in machinery control and automation systems, where reliable performance is crucial.
Commercial Use
For commercial buildings, it helps in managing energy distribution efficiently, ensuring smooth operation of various systems.
Residential Scenarios
Even in residential areas, this device can be used to manage power distribution, providing homeowners with a reliable energy management solution.
Installation Process
Installing it is straightforward if you follow these steps:
- Prepare the Tools: Ensure you have all necessary tools such as screwdrivers, wire strippers, and multimeters.
- Turn Off Power: Always turn off the main power supply before starting the installation.
- Mount the Device: Secure the Schneider C11F3TM080B in the designated location.
- Connect the Wires: Follow the wiring diagram provided in the manual to connect the device.
- Test the Installation: Once connected, turn on the power and test the device to ensure it’s working correctly.
Maintenance Tips
To keep the Schneider C11F3TM080B in optimal condition, regular maintenance is essential. Here are some tips:
- Routine Inspections: Regularly check for any signs of wear and tear.
- Clean the Enclosure: Keep the device clean to prevent dust accumulation.
- Check Connections: Ensure all connections are secure and corrosion-free.
Advantages of Using Schneider C11F3TM080B
Cost Savings
The energy-efficient design of it leads to significant cost savings over time by reducing electricity bills.
Environmental Benefits
By consuming less energy, this device contributes to reducing the carbon footprint, making it an environmentally friendly choice.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 160F |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 80 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 6.96 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Compression lug/busbar |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Trip unit rating | 80 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1000 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.06 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 8.1 cm |
| Package 1 Width | 13.7 cm |
| Package 1 Length | 8 cm |
| Package 1 Weight | 1.152 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 12.29 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 216 |
| Package 3 Height | 150 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 304.89 kg |