Schneider C11F3TM080L | circuit breaker ComPacT NSXm F (36 kA at 415 VAC). 3P 3d. 80 A rating TMD trip unit.
Schneider C11F3TM080L | circuit breaker ComPacT NSXm F (36 kA at 415 VAC). 3P 3d. 80 A rating TMD trip unit.
Description
Schneider C11F3TM080L: The Ultimate Guide
Introduction to Schneider C11F3TM080L
it is a name that resonates with excellence in the electrical and automation industry. If you’re looking for a reliable, efficient, and durable solution, this product might just be the perfect fit. In this comprehensive guide, we’ll delve deep into what makes it a standout choice.
Understanding the Schneider C11F3TM080L
Specifications
When it comes to electrical components, specifications are everything. it boasts impressive specs:
- Voltage: 240V
- Current: 80A
- Frequency: 50/60Hz
- Dimensions: 150 x 100 x 60 mm
Features
What sets it apart? Here are some key features:
- High Efficiency: Designed to maximize energy use.
- Durability: Built to withstand harsh industrial environments.
- User-friendly Interface: Easy to install and operate.
Key Benefits of the Schneider C11F3TM080L
Efficiency
Efficiency is a hallmark of it. With its advanced technology, it ensures minimal energy wastage and optimal performance.
Durability
Constructed with high-quality materials, this product is built to last. Whether in a factory or a commercial building, it can handle the demands of any environment.
Applications of the Schneider C11F3TM080L
Industrial Uses
Industries such as manufacturing, automation, and energy rely heavily on the Schneider C11F3TM080L for its robust performance and reliability.
Commercial Uses
In commercial settings, it ensures seamless electrical operations, providing a steady supply of power and enhancing overall operational efficiency.
Installation and Setup
Pre-installation Requirements
Before installation, ensure you have:
- A compatible power source.
- Appropriate mounting tools.
- Necessary safety gear.
Step-by-step Installation Guide
- Turn off the Power: Safety first—make sure all power sources are off.
- Mount the Device: Secure the Schneider C11F3TM080L on a stable surface.
- Connect the Wires: Follow the wiring diagram provided in the manual.
- Power On: Once everything is in place, turn on the power and test the device.
Operational Guidelines
Daily Operation
Operate it within its specified limits to ensure longevity. Regularly check for any signs of wear or issues.
Safety Precautions
Always follow safety protocols:
- Use appropriate personal protective equipment (PPE).
- Regularly inspect the device for any potential hazards.
Maintenance Tips
Regular Maintenance
- Monthly Inspections: Check for any visible damage or irregularities.
- Annual Servicing: Have a professional service the device annually to ensure peak performance.
Troubleshooting Common Issues
- Power Fluctuations: Check connections and ensure a stable power source.
- Overheating: Ensure proper ventilation and check for any obstructions.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 160F |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 80 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 6.96 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Trip unit rating | 80 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1000 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.06 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.0 cm |
| Package 1 Width | 9.0 cm |
| Package 1 Length | 21.0 cm |
| Package 1 Weight | 1.206 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 11.24 kg |
Reviews