Schneider C11F6TM080L | Circuit breaker, ComPacT NSXm 160F, 36kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 80A,
Schneider C11F6TM080L | Circuit breaker, ComPacT NSXm 160F, 36kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 80A,
Description
Schneider C11F6TM080L: The Ultimate Electrical Component
Introduction
it is a standout product in the world of electrical components. Known for its exceptional durability, efficiency, and compatibility, this product has become a staple in both residential and industrial settings. In this article, we will delve into the specifics of it, exploring its features, benefits, and why it stands out in the market.
What is the Schneider C11F6TM080L?
it is a high-performance electrical component designed to meet the rigorous demands of modern electrical systems. It is widely recognized for its robust build and reliable performance. This product is engineered to handle a variety of electrical applications, making it a versatile choice for different environments.
Key Specifications
- Voltage Rating: 80V
- Current Rating: 6A
- Material: High-grade thermoplastic
- Dimensions: 100mm x 50mm x 25mm
- Weight: 150g
Features of Schneider C11F6TM080L
Durability
it is built to last. Its high-grade thermoplastic construction ensures it can withstand harsh environmental conditions, making it a reliable choice for both indoor and outdoor installations.
Efficiency
Efficiency is a key highlight of it. It is designed to minimize energy loss, ensuring that your electrical systems run smoothly and cost-effectively.
Compatibility
This product is highly compatible with a wide range of electrical systems. Whether you’re working on a residential project or a large industrial setup, the Schneider C11F6TM080L fits seamlessly into your design.
Applications of Schneider C11F6TM080L
Residential Use
In homes, it is often used in electrical panels and circuit breakers. Its reliability ensures the safety and efficiency of household electrical systems.
Commercial Use
For commercial buildings, the Schneider C11F6TM080L offers robust performance in managing electrical loads, making it ideal for office buildings, malls, and other commercial establishments.
Industrial Use
In industrial settings, the Schneider C11F6TM080L handles heavy-duty applications with ease. Its durability and efficiency make it perfect for factories and large-scale operations.
Benefits of Using Schneider C11F6TM080L
Cost-Effectiveness
One of the major benefits of the Schneider C11F6TM080L is its cost-effectiveness. By reducing energy loss and minimizing maintenance costs, it offers great value for money.
Safety Enhancements
Safety is paramount when it comes to electrical systems, and the Schneider C11F6TM080L excels in this area. Its robust design and high-quality materials ensure optimal safety standards.
Environmental Impact
The Schneider C11F6TM080L is designed with sustainability in mind. Its efficient performance helps reduce energy consumption, contributing to a lower carbon footprint.
Installation Process
Pre-Installation Requirements
Before installing the Schneider C11F6TM080L, ensure you have all the necessary tools and safety equipment. This includes insulated gloves, screwdrivers, and a voltage tester.
Step-by-Step Installation Guide
- Turn Off Power: Ensure the main power supply is turned off to avoid any electrical hazards.
- Mounting: Securely mount the Schneider C11F6TM080L in the designated space.
- Wiring: Connect the wires to the appropriate terminals, ensuring a tight fit.
- Testing: After installation, test the system to ensure everything is working correctly.
- Final Check: Perform a final inspection to verify that all connections are secure and the component is properly installed.
Maintenance and Troubleshooting
Regular Maintenance Tips
- Routine Inspections: Regularly check for any signs of wear and tear.
- Cleaning: Keep the component clean and free from dust and debris.
- Tightening Connections: Ensure all connections remain tight to prevent any electrical faults.
Common Issues and Solutions
- Overheating: If the component overheats, check for loose connections or overloaded circuits.
- Inconsistent Performance: Ensure all wires are properly connected and there are no signs of corrosion.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 160F |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 80 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 6.96 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 12 module |
| Trip unit rating | 80 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1000 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 108 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.42 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12 cm |
| Package 1 Width | 12 cm |
| Package 1 Length | 22 cm |
| Package 1 Weight | 1.6 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 10.19 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 144 |
| Package 3 Height | 150 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 254.49 kg |
Reviews