Schneider C11H3TM040B | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 3 poles, TMD trip unit 40A
Schneider C11H3TM040B | Circuit breaker, ComPacT NSXm 63H, 70kA/415VAC, 3 poles, TMD trip unit 40A
Description
Schneider C11H3TM040B: A Comprehensive Guide
Introduction
In the realm of industrial components, understanding the specifications and capabilities of each part is crucial for ensuring optimal performance and reliability. One such component that has gained significant attention is the Schneider C11H3TM040B. This guide provides an in-depth look at this exceptional product, detailing its features, applications, benefits, and more.
What is the Schneider C11H3TM040B?
it is a high-performance industrial component designed by Schneider Electric, a global leader in energy management and automation. This product is known for its robust design and exceptional functionality, making it a reliable choice for various applications.
Key Features
- High Durability: Engineered to withstand demanding environments.
- Advanced Technology: Utilizes the latest innovations in electrical engineering.
- Versatility: Suitable for a broad range of applications.
Technical Specifications
Understanding the technical specifications of it is essential for ensuring it meets your specific needs.
Electrical Characteristics
- Voltage Rating: Designed to handle high voltage levels efficiently.
- Current Rating: Optimized for superior current flow.
- Power Consumption: Energy-efficient design reduces operational costs.
Mechanical Properties
- Material: Constructed from high-quality, durable materials.
- Dimensions: Compact design for easy integration.
- Weight: Lightweight, facilitating easy handling and installation.
Environmental Considerations
- Operating Temperature: Performs reliably across a wide temperature range.
- Humidity Resistance: Built to resist moisture and humidity effectively.
- Safety Standards: Complies with international safety regulations.
Applications of the Schneider C11H3TM040B
it is highly versatile and finds applications in various sectors.
Industrial Uses
- Manufacturing Plants: Enhances machinery efficiency and reliability.
- Power Stations: Integral component for efficient electrical management.
Commercial Uses
- Office Buildings: Ensures reliable and consistent electrical supply.
- Retail Stores: Supports diverse electrical needs effectively.
Residential Uses
- Home Automation Systems: Integral to advanced home automation solutions.
- Safety Systems: Plays a key role in modern home security setups.
Benefits of Using the Schneider C11H3TM040B
Investing in the Schneider C11H3TM040B comes with numerous advantages.
Reliability
One of the standout features of it is its reliability. It guarantees consistent performance, minimizing the risk of downtime in critical operations.
Efficiency
The C11H3TM040B is designed for maximum efficiency, making it a cost-effective choice for a wide range of applications.
Versatility
Thanks to its versatile design, the C11H3TM040B can be used in various settings, from industrial to residential, ensuring broad applicability.
Installation Process
Proper installation of it is crucial for its performance.
Pre-installation Requirements
- Tools Needed: List of necessary tools for installation.
- Safety Gear: Recommended safety equipment to ensure a safe installation process.
Step-by-Step Installation Guide
- Preparation: Gather all required tools and components.
- Mounting: Secure the C11H3TM040B in its designated location.
- Wiring: Connect the electrical wires as per the installation manual.
- Testing: Verify the installation with a series of tests to ensure proper functionality.
Safety Tips
- Follow Instructions: Adhere strictly to the manufacturer’s guidelines.
- Use Protective Gear: Always wear appropriate safety equipment.
- Double-check Connections: Ensure all connections are secure before powering up the device.
Maintenance and Troubleshooting
Maintaining the Schneider C11H3TM040B ensures its longevity and optimal performance.
Regular Maintenance Practices
- Routine Inspections: Schedule regular checks to ensure everything is in working order.
- Cleaning: Keep the component free of dust and debris.
- Updates: Apply firmware and software updates as needed.
Common Issues and Solutions
- Overheating: Ensure proper ventilation to avoid overheating.
- Power Fluctuations: Check connections and load capacity to manage power fluctuations.
- Mechanical Wear: Replace worn-out parts promptly to maintain performance.
When to Seek Professional Help
If troubleshooting steps do not resolve the issue, it’s advisable to seek professional assistance to prevent further damage and ensure safety.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63H |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 40 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | H 70 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 3.46 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Compression lug/busbar |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Trip unit rating | 40 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 600 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.06 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.000 cm |
| Package 1 Width | 22.000 cm |
| Package 1 Length | 13.000 cm |
| Package 1 Weight | 1.300 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 12.290 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 216 |
| Package 3 Height | 150.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 304.890 kg |