Schneider C11H3TM080L: Enhancing Efficiency in Industrial Automation
Introduction
In the realm of industrial automation, finding robust and reliable components is crucial. The Schneider C11H3TM080L stands out as a versatile solution that ensures seamless operations in various industrial settings. This article delves into the specifications, applications, benefits, and more of the Schneider C11H3TM080L.
What is Schneider C11H3TM080L?
it is a high-performance component designed to optimize industrial automation systems. Known for its durability and advanced features, it plays a pivotal role in enhancing efficiency and productivity across different sectors.
Technical Specifications
Understanding the technical details is essential when evaluating it:
Dimensions and Weight
- Dimensions: Compact design suitable for various installation setups.
- Weight: Lightweight construction for ease of handling.
Electrical Specifications
- Voltage Range: Operates efficiently across a broad voltage spectrum.
- Power Consumption: Optimized for minimal energy usage without compromising performance.
Environmental Ratings
- Temperature Range: Designed to function reliably in diverse temperature conditions.
- Humidity Resistance: Built to withstand high humidity environments.
Applications of Schneider C11H3TM080L
The versatility of it makes it suitable for a wide range of applications:
Industrial Applications
Used in manufacturing plants to control and monitor machinery, optimizing production processes.
Commercial Uses
Ideal for building management systems, automating tasks such as lighting and HVAC controls.
Home Automation
A key component in smart home systems, facilitating automation of various household functions.
Benefits of Using Schneider C11H3TM080L
Why should industries choose it? Here are its main advantages:
Efficiency
Enhances operational efficiency by streamlining processes and reducing downtime.
Reliability
Built to last, ensuring consistent performance even in demanding industrial environments.
Cost-Effectiveness
Offers a high return on investment through energy savings and reduced maintenance costs.
Installation Process
Installing the Schneider C11H3TM080L is straightforward with these steps:
Pre-installation Requirements
Ensure all necessary tools and equipment are available.
Step-by-Step Installation Guide
- Preparation: Gather tools and safety gear.
- Mounting: Secure the component in place as per guidelines.
- Connections: Connect electrical wiring correctly.
- Testing: Verify functionality after installation.
Safety Considerations
Safety is paramount when dealing with industrial components like the Schneider C11H3TM080L:
Compliance with Safety Standards
The Schneider C11H3TM080L meets stringent international safety standards.
Safety Tips During Installation and Use
- Always follow installation instructions carefully.
- Conduct regular inspections to ensure safe operation.
Maintenance and Troubleshooting
Maintaining peak performance requires regular upkeep:
Regular Maintenance Tips
- Clean periodically to prevent dust buildup.
- Inspect for wear and tear on components.
Common Issues and Solutions
- Issue: Component heating up excessively.
- Solution: Check ventilation and airflow around the unit.
- Issue: Inconsistent performance.
- Solution: Inspect for loose connections and rectify promptly.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 160H |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 80 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | H 70 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 6.96 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Trip unit rating | 80 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1000 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.06 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.0 cm |
| Package 1 Width | 9.0 cm |
| Package 1 Length | 21.0 cm |
| Package 1 Weight | 1.206 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 11.21 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider C12N3TM125B | Circuit breaker, ComPacT NSXm 160N, 50kA/415VAC, 3 poles, TMD trip unit 125A, lugs/busbars
Schneider C12E6TM125L | Circuit breaker ComPacT NSXm E (16kA at 415VAC), 4 Poles 3d, 125A rating TMD trip unit, EverLink connectors
Schneider C12E3TM125B | Circuit breaker, ComPacT NSXm 160E, 16kA/415VAC, 3 poles, TMD trip unit 125A, lugs/busbars
Schneider C12B6TM160L | Circuit breaker ComPacT NSXm B (25kA at 415VAC), 4 Poles 3d, 160A rating TMD trip unit, EverLink connectors
Schneider C11N6TM040B | Circuit breaker, ComPacT NSXm 63N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 40A, lugs/busbars
-
0
Reviews
There are no reviews yet.