Description

Schneider C11H6TM032L: A Comprehensive Guide

Introduction

The Schneider C11H6TM032L is a versatile and reliable circuit breaker designed to protect electrical circuits from damage caused by overloads and short circuits. This guide will explore the features, applications, technical specifications, and benefits of the Schneider C11H6TM032L, providing a detailed understanding of why it is an excellent choice for various electrical protection needs.

What is the Schneider C11H6TM032L?

The Schneider C11H6TM032L is a thermal-magnetic circuit breaker from Schneider Electric’s C11 series. It combines thermal protection for overload conditions and magnetic protection for short-circuit conditions, ensuring the safety and reliability of electrical systems.

General Description

This circuit breaker is designed to protect electrical circuits by interrupting the flow of current in case of overloads or short circuits. Its robust construction and reliable performance make it suitable for a wide range of applications.

Key Specifications

  • Voltage Rating: Up to 690V AC
  • Current Rating: 32A
  • Breaking Capacity: 10 kA
  • Number of Poles: 3
  • Trip Class: 10A

Intended Applications

it is used in various settings, including residential, commercial, and industrial environments, to protect electrical circuits for motors, lighting systems, and other equipment.

Features of Schneider C11H6TM032L

it offers several features that make it a reliable and efficient choice for circuit protection.

High Performance

The circuit breaker is designed to handle significant electrical loads, providing robust protection against overloads and short circuits.

Compact Design

Its compact design allows for easy installation in electrical panels and distribution boards, making it suitable for use in tight spaces.

Safety Features

The C11H6TM032L includes thermal-magnetic protection to prevent overheating and short-circuits. It also has a manual reset button for added convenience.

Technical Specifications

To fully understand the capabilities of the Schneider C11H6TM032L, let’s delve into its technical specifications.

Voltage Ratings

The C11H6TM032L can operate effectively at voltages up to 690V AC, making it suitable for a wide range of electrical systems.

Current Capacity

With a current rating of 32A, this circuit breaker can manage substantial electrical loads, ensuring reliable performance in various applications.

Breaking Capacity

The circuit breaker has a breaking capacity of 10 kA, which means it can interrupt short-circuit currents up to 10,000 amps without sustaining damage.

Trip Class

The trip class of 10A indicates that the breaker will trip within a specific time frame under overload conditions, providing reliable protection for your electrical circuits.

Installation and Setup

Proper installation is crucial for it to function effectively. Here’s a step-by-step guide to help you with the process.

Pre-installation Requirements

Before starting the installation, ensure you have the following:

  • Necessary tools and safety gear
  • A clear and accessible installation site
  • The correct wiring diagram for your setup

Step-by-step Installation Guide

  1. Turn off Power: Make sure the power supply is completely turned off to avoid electrical hazards.
  2. Mount the Breaker: Install it into the designated slot in your electrical panel or distribution board.
  3. Connect Wires: Connect the incoming and outgoing wires to the breaker terminals, following the wiring diagram.
  4. Check Connections: Ensure all connections are secure and properly aligned.
  5. Restore Power: Turn the power back on and test the breaker to verify that it is functioning correctly.

Safety Precautions During Installation

Always follow electrical safety practices:

  • Wear appropriate protective gear.
  • Ensure the installation area is dry and free of any hazards.
  • Double-check all connections before restoring power.

Additional information

brands

Schneider Electric

Specifications

Main
Range ComPacT new generation
Product name ComPacT NSXm new generation
Range of product ComPacT NSXm new generation
Device short name NSXm 63H
product or component type Circuit breaker
Device application Distribution
poles description 4P
Protected poles description 3D
Neutral position Left
[In] rated current 32 A at 40 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
[Icu] rated ultimate short-circuit breaking capacity 100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Performance level H 70 kA 415 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed
Complementary
[Ui] rated insulation voltage 800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 8 kV
[Ics] rated service short-circuit breaking capacity 100 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Power dissipation per pole 2.94 W
mounting support Backplate
Mounting position Horizontal and vertical Flat on the back
Upside connection Front
downside connection Front
Connection terminals 1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper 1 Everlink lug wire size 2.5…70 mm², flexible copper
Connection pitch 35 mm with spreaders 27 mm without spreaders
9 mm pitches 12 module
Trip unit rating 32 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.7...1 x In
Long-time protection delay adjustment type tr Fixed
Neutral protection settings No protection (3D)
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 600 A
Earth-leakage protection Without
Number of slots for electrical auxiliaries 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX
Local signalling Flag (green) for presence of auxiliary contacts
Width (W) 108 mm
Height (H) 137 mm
Depth (D) 80 mm
net weight 1.42 kg
Colour Grey (RAL 7016)
Environment
Standards EN/IEC 60947
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 2000 m without derating 5000 m with derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 13 cm
Package 1 Width 12 cm
Package 1 Length 22 cm
Package 1 Weight 1.6 kg
Unit Type of Package 2 S03
Number of Units in Package 2 6
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 10.19 kg
Unit Type of Package 3 P12
Number of Units in Package 3 144
Package 3 Height 150 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 254.49 kg

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider C11H6TM032L | Circuit breaker ComPacT NSXm H (70kA at 415VAC), 4 Poles 3d, 32A rating TMD trip unit, EverLink connectors”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare