Schneider C11N3TM025B | Circuit breaker ComPacT NSXm N (50kA at 415VAC), 3 Poles 3d, 25A rating TMD trip unit, compression lugs and busbar connectors
Schneider C11N3TM025B | Circuit breaker ComPacT NSXm N (50kA at 415VAC), 3 Poles 3d, 25A rating TMD trip unit, compression lugs and busbar connectors
Description
Schneider C11N3TM025B: Everything You Need to Know
Introduction
The Schneider C11N3TM025B is a crucial component in Schneider Electric’s range of electrical solutions, renowned for its reliability and performance. This article provides an in-depth overview of its features, applications, and benefits.
Overview of Schneider Electric
Company History
Schneider Electric boasts a distinguished history of over a century, specializing in energy management and automation solutions. The company is celebrated for its commitment to innovation and sustainability.
Commitment to Quality
Emphasizing quality across all products, Schneider Electric ensures adherence to stringent standards for performance, safety, and efficiency.
Key Features of Schneider C11N3TM025B
High Performance
The Schneider C11N3TM025B excels in high-performance applications, delivering reliable operation under diverse conditions.
Durability
Constructed from durable materials, this component guarantees longevity and minimal maintenance requirements, even in demanding environments.
Safety Features
Incorporates advanced safety mechanisms to safeguard against electrical hazards, prioritizing user protection.
Technical Specifications
Voltage and Current Ratings
Operates at a specific voltage rating and supports a maximum current of [insert specific ratings], suitable for various electrical setups.
Physical Dimensions
Compact design facilitates straightforward installation in electrical panels with minimal spatial requirements.
Installation Requirements
Simple installation process necessitates basic tools and adherence to safety protocols for optimal functionality.
Applications of Schneider C11N3TM025B
Industrial Uses
Optimal for industrial environments requiring robust electrical components to manage power efficiently.
Commercial Buildings
Deployed in commercial settings to ensure reliable power distribution and enhance energy efficiency.
Residential Settings
Applicable in residential applications where dependable electrical performance is imperative.
Benefits of Using Schneider C11N3TM025B
Enhanced Efficiency
Improves energy efficiency, reducing operational costs and environmental impact for sustainable practices.
Reliability
Consistent performance guarantees uninterrupted power supply, critical for industrial and commercial operations.
Cost-Effectiveness
Delivers long-term savings through reduced energy consumption and maintenance expenditures.
Installation Process
Step-by-Step Guide
- Preparation: Gather necessary tools and review installation instructions thoroughly.
- Safety: Disconnect power source and follow established safety protocols.
- Mounting: Secure the C11N3TM025B in the designated panel space securely.
- Wiring: Connect according to manufacturer guidelines, ensuring appropriate insulation.
- Testing: Validate functionality before restoring power to ensure operational integrity.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSXm new generation |
| Range of product | ComPacT NSXm new generation |
| Device short name | NSXm 63N |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 25 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 90 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | N 50 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 90 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 2.5 kA at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 2.83 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection terminals | Compression lug/busbar |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Trip unit rating | 25 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 600 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Local signalling | Flag (green) for presence of auxiliary contacts |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| net weight | 1.06 kg |
| Colour | Grey (RAL 7016) |
| Standards | EN/IEC 60947 |
|---|---|
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 2000 m without derating 5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.000 cm |
| Package 1 Width | 9.000 cm |
| Package 1 Length | 22.000 cm |
| Package 1 Weight | 1.300 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 12.290 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 216 |
| Package 3 Height | 150.000 cm |
| Package 3 Width | 80.000 cm |
| Package 3 Length | 120.000 cm |
| Package 3 Weight | 304.890 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
Schneider C12F44V160L | Circuit breaker, ComPacT NSXm 160F, 36kA/415VAC, 4 poles, MicroLogic 4.1 trip unit 160A, EverLink lugs
Schneider C12E3TM160B | Circuit breaker, ComPacT NSXm 160E, 16kA/415VAC, 3 poles, TMD trip unit 160A, lugs/busbars
Schneider C12E3TM125B | Circuit breaker, ComPacT NSXm 160E, 16kA/415VAC, 3 poles, TMD trip unit 125A, lugs/busbars
Schneider C12B3TM160B | Circuit breaker, ComPacT NSXm 160B, 25kA/415VAC, 3 poles, TMD trip unit 160A, lugs/busbars
Schneider C11N6TM032L | Circuit breaker, ComPacT NSXm 63N, 50kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 32A, EverLink lugs
-
0