Schneider C16H6TM160 | Circuit breaker, ComPacT NSX160H, 70kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 160A
Schneider C16H6TM160 | Circuit breaker, ComPacT NSX160H, 70kA/415VAC, 4 poles 3D (neutral not protected), TMD trip unit 160A
Description
Schneider C16H6TM160: Enhancing Electrical Safety and Efficiency
In today’s interconnected world, reliable circuit protection is essential for ensuring the safety and efficiency of electrical systems. it stands out as a versatile and robust circuit breaker, designed to meet the diverse needs of residential, commercial, and industrial applications.
Introduction to Schneider C16H6TM160
Overview
it is a high-performance circuit breaker that safeguards electrical circuits from overloads and short circuits. It is engineered to deliver uninterrupted power supply and prevent damage to connected equipment.
Importance of Reliable Circuit Protection in Electrical Systems
Circuit breakers like it play a critical role in protecting electrical installations and ensuring the safety of users. They detect faults in the electrical network and automatically disconnect the circuit to prevent hazards such as fires and electrical shocks.
Features and Specifications
Voltage Rating and Current Capacity of Schneider C16H6TM160
it is rated for [specify voltage] and can handle currents up to [specify amperage], making it suitable for a wide range of applications.
Types of Circuits Suitable for Schneider C16H6TM160
It is ideal for [mention types of circuits], providing reliable protection in various electrical setups.
Key Technical Specifications
- [List specific technical details]
- [Highlight any unique features]
Advantages
Reliability and Durability in Protecting Electrical Circuits
it ensures reliable protection against overloads and short circuits, minimizing downtime and repair costs.
Efficiency in Energy Management
By optimizing power distribution, it contributes to energy efficiency, reducing electricity consumption.
Longevity and Cost-Effectiveness
Built to withstand rigorous use, it offers a long operational life, making it a cost-effective investment for users.
Applications in Different Industries
Residential Applications
In homes, it provides peace of mind by securing electrical circuits and ensuring safety for residents.
Commercial and Industrial Uses
Industries rely on it for robust electrical protection in demanding environments, enhancing operational reliability.
Safety Features for Diverse Environments
With advanced safety features, it meets the stringent requirements of diverse settings, ensuring user safety.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX160H |
| product or component type | Circuit breaker |
| Device application | Distribution |
| poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 160 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | H 70 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| Control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 40000 cycles |
| Electrical durability | 40000 cycles at 440 V In/2 20000 cycles at 440 V In 15000 cycles at 690 V In/2 7500 cycles at 690 V In |
| Power dissipation per pole | 13.95 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 160 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 1250 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 140 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| net weight | 2.6 kg |
| Standards | EN/IEC 60947 |
|---|---|
| Product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| Ambient air temperature for operation | -25…70 °C |
| ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 14.5 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 2.376 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 9.888 kg |