Schneider C25N6TM200: Product Overview and Applications
Introduction
The Schneider C25N6TM200 is a robust molded case circuit breaker (MCCB) rated at 200A, designed to provide reliable circuit protection for high-demand electrical systems. Equipped with a thermal-magnetic trip unit, this MCCB is capable of handling both overloads and short circuits, making it ideal for industrial, commercial, and critical infrastructure applications where electrical safety is essential. The C25N6TM200’s combination of durability, high breaking capacity, and flexible trip settings makes it a valuable choice for a wide range of power distribution needs.
Key Features of Schneider C25N6TM200
- Rated Current of 200A: Ideal for applications requiring high power and effective circuit protection, ensuring system stability under heavy loads.
- Thermal-Magnetic Trip Unit: Dual protection mechanism with thermal response for gradual overloads and magnetic response for instantaneous short-circuit protection.
- High Breaking Capacity: Capable of safely interrupting large fault currents, protecting both equipment and personnel from electrical hazards.
- Durable and Compact Design: Built to withstand challenging environments, yet compact enough to fit standard electrical panels.
- Adjustable Trip Settings: Provides customizable protection settings, allowing for flexibility and optimal performance across various applications.
Applications of Schneider C25N6TM200
- Industrial Machinery and Equipment: Protects high-power machinery, such as pumps, motors, and conveyor belts, from electrical faults, ensuring the safe operation of manufacturing equipment.
- Commercial Power Distribution: Suitable for commercial facilities, ensuring stable power distribution for HVAC systems, lighting, and other essential systems.
- Data Centers and IT Facilities: Provides reliable protection in data centers and IT infrastructure, where uninterrupted power and circuit integrity are critical.
- Renewable Energy Systems: Ensures fault protection in renewable energy setups like solar or wind power installations, where variable loads can create challenges.
- Substation and Utility Protection: Provides dependable circuit protection for substations and utility networks, where system reliability and fault tolerance are paramount.
Benefits of Using Schneider C25N6TM200
- High-Performance Protection for Heavy Loads: Ensures the safe operation of high-power systems by providing robust protection against overloads and short circuits.
- Flexible and Versatile: Adjustable trip settings make this MCCB adaptable to various environments and application needs, enhancing both safety and operational efficiency.
- Compact, Space-Saving Design: Compact construction allows for efficient integration in standard panels, maximizing space without compromising performance.
- Minimal Maintenance Requirements: Designed for durability and longevity, reducing the need for frequent maintenance or replacement and providing long-term cost savings.
Conclusion
The Schneider C25N6TM200 MCCB is a powerful and adaptable circuit breaker suited for high-demand environments in industrial and commercial settings. With its 200A rating, high breaking capacity, and dual thermal-magnetic protection, it provides a reliable solution for safeguarding critical equipment and systems. Whether used in industrial machinery, data centers, or renewable energy installations, the C25N6TM200 offers the safety and flexibility needed to protect modern electrical infrastructures.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX250N |
| Product or component type | Circuit breaker |
| Device application | Distribution |
| Poles description | 4P |
| Protected poles description | 3D |
| Neutral position | Left |
| [In] rated current | 200 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 600 V AC 50/60 Hz conforming to UL 508 |
| Performance level | N 50 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In |
| Power dissipation per pole | 15.4 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 35 mm |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 200 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 120…400 s at 1.5 x In 15 s at 6 x Ir |
| Neutral protection settings | No protection (3D) |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [Ii] instantaneous protection pick-up adjustment range | 5...10 x In |
| earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 5 slot(s) |
| Width (W) | 140 mm |
| Height (H) | 161 mm |
| Depth (D) | 86 mm |
| Net weight | 2.8 kg |
| Standards | EN/IEC 60947 |
|---|---|
| product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 14.0 cm |
| Package 1 Width | 14.5 cm |
| Package 1 Length | 19.0 cm |
| Package 1 Weight | 2.628 kg |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 3 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 8.274 kg |