new-34%On Sale
Schneider C63N32D630 | Circuit breaker, ComPacT NSX630N, 50kA/415VAC, 3 poles, MicroLogic 2.3 trip unit 630A
Schneider C63N32D630 | Circuit breaker, ComPacT NSX630N, 50kA/415VAC, 3 poles, MicroLogic 2.3 trip unit 630A
C63N32D630
Description
Schneider C63N32D630: Complete Product Overview
Introduction
The Schneider C63N32D630 is a high-performance molded case circuit breaker (MCCB) designed for heavy-duty applications that require reliable protection against electrical faults. With a 630A rating, this MCCB is ideal for large-scale industrial, commercial, and utility systems where significant electrical loads are handled. The C63N32D630 uses Schneider’s advanced thermal-magnetic trip technology to offer dual protection against overloads and short circuits, making it an essential component for ensuring the safety and reliability of electrical installations.
Key Features of Schneider C63N32D630
- 630A Current Rating: Provides superior protection for circuits with high current demands, ideal for industrial and commercial applications.
- Thermal-Magnetic Trip Mechanism: Combines both thermal protection for overloads and magnetic protection for instantaneous short-circuit response.
- High Breaking Capacity: Designed to safely interrupt high fault currents, preventing potential damage to equipment and infrastructure.
- Compact Design: Despite its powerful capabilities, the C63N32D630 is designed to be space-efficient, easily fitting into standard electrical panels.
- Adjustable Trip Settings: Offers customizable settings for both thermal and magnetic trip characteristics, allowing flexibility for different systems.
Applications of Schneider C63N32D630
- Industrial Power Distribution: Protects high-capacity industrial equipment such as motors, transformers, and compressors, ensuring consistent operation.
- Commercial and Institutional Buildings: Ideal for protecting electrical distribution systems in large office buildings, shopping centers, and healthcare facilities.
- Renewable Energy Systems: Suitable for use in solar power, wind, and other renewable energy installations, where load fluctuations and fault protection are essential.
- Data Centers and IT Networks: Provides protection for critical IT infrastructure by safeguarding power distribution systems against overloads and short circuits.
- Utility Networks and Substations: Works in utility applications to protect power distribution networks, ensuring reliable service and preventing disruptions.
Benefits of Schneider C63N32D630
- Robust Protection for Heavy Loads: The 630A rating is designed for high-power systems, ensuring protection in demanding environments where large electrical loads are present.
- Dual Protection Mechanism: The thermal-magnetic trip unit offers comprehensive protection, responding quickly to both short circuits and overload conditions.
- Customizable Settings: The adjustable trip settings allow for tailored protection to meet specific system requirements, enhancing flexibility.
- Space-Efficient Design: Its compact size makes it suitable for crowded panels without compromising on performance or safety.
- Durable and Low-Maintenance: Designed with longevity in mind, the C63N32D630 requires minimal maintenance, providing long-term, reliable protection.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | ComPacT new generation |
|---|---|
| Product name | ComPacT NSX new generation |
| Device short name | NSX630N |
| Product or component typee | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3D |
| [In] rated current | 630 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 480 V AC 50/60 Hz conforming to UL 508 |
| Performance level | N 50 kA 415 V AC |
| Trip unit name | MicroLogic 2.3 |
| Trip unit technology | Electronic |
| Trip unit protection functions | LSoI |
| control type | Toggle |
| Circuit breaker mounting mode | Fixed |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 15000 cycles |
| Electrical durability | 8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In |
| Power dissipation per pole | 39.69 W |
| mounting support | Backplate |
| Mounting position | Horizontal and vertical Flat on the back |
| Upside connection | Front |
| downside connection | Front |
| Connection pitch | 45 mm |
| Protection type | L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection |
| Trip unit rating | 630 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable 9 settings |
| [Ir] long-time protection pick-up adjustment range | 250...630 A |
| Long-time protection delay adjustment type tr | Fixed |
| [tr] long-time protection delay adjustment range | 400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir |
| thermal memory | 20 minutes before and after tripping |
| Short-time protection pick-up adjustment type Isd | Adjustable 9 settings |
| [Isd] Short-time protection pick-up adjustment range | 1.5...10 x Ir |
| Short-time protection delay adjustment type tsd | Fixed |
| Instantaneous protection pick-up adjustment type Ii | Fixed |
| [Ii] instantaneous protection pick-up adjustment range | 6900 A |
| earth-leakage protection | Without |
| Zone selective interlocking ZSI | Without |
| Number of slots for electrical auxiliaries | 6 slot(s) |
| Local signalling | Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload |
| Width (W) | 140 mm |
| Height (H) | 255 mm |
| Depth (D) | 110 mm |
| Net weight | 6.2 kg |
| Standards | EN/IEC 60947 |
|---|---|
| product certifications | CCC EAC Marine |
| Overvoltage category | Class II |
| Electrical shock protection class | Class II |
| Pollution degree | 3 conforming to IEC 60664-1 |
| IP degree of protection | IP40 conforming to IEC 60529 |
| IK degree of protection | IK07 conforming to IEC 62262 |
| ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Relative humidity | 0…95 % |
| Operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 15.0 cm |
| Package 1 Width | 16.0 cm |
| Package 1 Length | 29.5 cm |
| Package 1 Weight | 5.732 kg |
| Unit Type of Package 2 | S04 |
| Number of Units in Package 2 | 2 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 40.0 cm |
| Package 2 Length | 60.0 cm |
| Package 2 Weight | 12.318 kg |
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Be the first to review “Schneider C63N32D630 | Circuit breaker, ComPacT NSX630N, 50kA/415VAC, 3 poles, MicroLogic 2.3 trip unit 630A” Cancel reply
Reviews
There are no reviews yet.