Schneider LC1D40ABNE Contactor | TeSys D3P 40A AC-3 up to 440V coil 24-60V AC/DC EverLink
Schneider LC1D40ABNE Contactor
Description
Schneider LC1D40ABNE Contactor: Enhancing Electrical Systems
In today’s rapidly advancing world, efficiency and reliability are paramount in every aspect of our lives, including electrical systems. Whether it’s in industrial settings, commercial buildings, or residential complexes, the demand for robust electrical components is ever-present. One such essential component that plays a pivotal role in controlling electrical circuits is it.
Understanding the Significance of Contactors
Before delving into the specifics of it, let’s first grasp the concept of a contactor. Essentially, a contactor is an electromechanical switch used for controlling an electrical circuit. It is designed to handle large amounts of electrical current, making it indispensable in various applications where heavy-duty switching is required.
Overview of Schneider LC1D40ABNE Contactor
itis a standout product in the realm of contactors, renowned for its superior performance and reliability. With a rated operational current of 40A and a coil voltage of 24V AC, this contactor is well-suited for a wide range of industrial and commercial applications.
Specifications and Features
- Rated Operational Current: 40A
- Coil Voltage: 24V AC
- Number of Poles: 3
- AC-3 Utilization Category: AC-1, AC-3
- Auxiliary Contacts: 1NO + 1NC
Applications
The versatility of it makes it ideal for various applications, including:
- Motor control
- Lighting control
- Heating and ventilation systems
- Industrial machinery
Advantages of Using Schneider LC1D40ABNE Contactor
Reliability
One of the key advantages of it is its reliability. Built to withstand the rigors of demanding environments, this contactor ensures uninterrupted operation, thereby minimizing downtime and enhancing productivity.
Durability
Constructed with high-quality materials and precision engineering, it is built to last. Its robust design and corrosion-resistant components make it suitable for use in harsh industrial conditions.
Safety Features
Safety is paramount in any electrical system, and it prioritizes this aspect. With built-in overload protection and secure terminal connections, it offers peace of mind to users, ensuring safe and secure operation.
Installation and Maintenance
Installing it is a straightforward process, thanks to its user-friendly design and clear instructions. Regular maintenance, including visual inspections and testing, can further prolong its lifespan and ensure optimal performance.
Comparison with Other Contactors in the Market
In a market flooded with options, it stands out due to its superior quality, reliability, and performance. When compared to other contactors, it emerges as the preferred choice for discerning customers.
Case Studies: Real-world Applications of Schneider LC1D40ABNE Contactor
To illustrate its effectiveness, let’s explore some real-world applications where it has made a significant impact:
- Controlling industrial motors in manufacturing plants
- Regulating lighting systems in commercial buildings
- Managing heating and ventilation systems in warehouses
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys TeSys Deca |
|---|---|
| Range of product | TeSys Deca |
| Product or component type | Contactor |
| Device short name | LC1D |
| Contactor application | Resistive load Motor control |
| Utilisation category | AC-3 AC-1 AC-3e |
| Poles description | 3P |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz |
| [Ie] rated operational current | 60 A (at <60 °C) at <= 440 V AC-1 for power circuit 40 A (at <60 °C) at <= 440 V AC-3 for power circuit 40 A (at <60 °C) at <= 440 V AC-3e for power circuit |
| [Uc] control circuit voltage | 24...60 V AC 50/60 Hz 24...60 V DC |
| Motor power kW | 11 kW at 220...230 V AC 50 Hz (AC-3) 18.5 kW at 380...400 V AC 50 Hz (AC-3) 22 kW at 415 V AC 50 Hz (AC-3) 22 kW at 440 V AC 50 Hz (AC-3) 22 kW at 500 V AC 50 Hz (AC-3) 30 kW at 660...690 V AC 50 Hz (AC-3) 11 kW at 220...230 V AC 50 Hz (AC-3e) 18.5 kW at 380...400 V AC 50 Hz (AC-3e) 22 kW at 415 V AC 50 Hz (AC-3e) 22 kW at 440 V AC 50 Hz (AC-3e) 22 kW at 500 V AC 50 Hz (AC-3e) 30 kW at 660...690 V AC 50 Hz (AC-3e) |
|---|---|
| Motor power hp | 3 hp at 115 V AC 60 Hz for 1 phase motors 5 hp at 230/240 V AC 60 Hz for 1 phase motors 10 hp at 200/208 V AC 60 Hz for 3 phases motors 10 hp at 230/240 V AC 60 Hz for 3 phases motors 30 hp at 460/480 V AC 60 Hz for 3 phases motors 30 hp at 575/600 V AC 60 Hz for 3 phases motors |
| Compatibility code | LC1D |
| Pole contact composition | 3 NO |
| Protective cover | With |
| [Ith] conventional free air thermal current | 60 A (at 60 °C) for power circuit 10 A (at 60 °C) for signalling circuit |
| Irms rated making capacity | 800 A at 440 V for power circuit conforming to IEC 60947 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 |
| Rated breaking capacity | 800 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 72 A 40 °C - 10 min for power circuit 165 A 40 °C - 1 min for power circuit 320 A 40 °C - 10 s for power circuit 720 A 40 °C - 1 s for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit |
| Associated fuse rating | 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit 10 A gG for signalling circuit conforming to IEC 60947-5-1 |
| Average impedance | 1.5 mOhm - Ith 60 A 50 Hz for power circuit |
| Power dissipation per pole | 5.4 W AC-1 2.4 W AC-3 2.4 W AC-3e |
| [Ui] rated insulation voltage | Power circuit: 690 V conforming to IEC 60947-4-1 Signalling circuit: 690 V conforming to IEC 60947-1 |
| Overvoltage category | III |
| Pollution degree | 3 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability | 6 Mcycles |
| Electrical durability | 2 Mcycles 35 A AC-3 at Ue <= 440 V 0.7 Mcycles 60 A AC-1 at Ue <= 440 V 2 Mcycles 35 A AC-3e at Ue <= 440 V |
| Control circuit type | AC/DC at 50/60 Hz AC/DC electronic |
| Coil technology | Built-in bidirectional peak limiting |
| Control circuit voltage limits | <= 0.1 Uc (-40…70 °C):drop-out AC/DC 0.85...1.1 Uc (-40…60 °C):operational AC 0.8...1.1 Uc (-40…60 °C):operational DC 1...1.1 Uc (60…70 °C):operational AC/DC |
| Inrush power in VA | 15 VA 50/60 Hz (at 20 °C) |
| Inrush power in W | 16 W (at 20 °C) |
| Hold-in power consumption in VA | 1 VA 50/60 Hz (at 20 °C) |
| Hold-in power consumption in W | 0.7 W at 20 °C |
| Heat dissipation | 0.7 W at 50/60 Hz |
| Operating time | 55...65 ms closing 20...120 ms opening (date code >= 17221) 20...80 ms opening (date code >= 18011) |
| Maximum operating rate | 3600 cyc/h 60 °C |
| Maximum operating rate | 3600 cyc/h at 60 °C |
| Connections - terminals | Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible without cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible with cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: solid Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible without cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible with cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: solid |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on EverLink BTR screw connectors - cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - on EverLink BTR screw connectors - cable 1…25 mm² hexagonal screw head 4 mm Power circuit: 2.5 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M4 Control circuit: 1.7 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5 |
| Auxiliary contact composition | 1 NO + 1 NC |
| Auxiliary contacts type | type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency | 25...400 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| Minimum switching current | 5 mA for signalling circuit |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Non-overlap time | 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact |
| Mounting support | Plate Rail |
| Standards | EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 CSA C22.2 No 14 UL 60947-4-1 IEC 60335-2-40:Annex JJ UL 60335-2-40:Annex JJ IEC 60335-1:Clause 30.2 |
|---|---|
| Product certifications | CCC CSA EAC UL KC DNV-GL LROS (Lloyds register of shipping) UKCA |
| IP degree of protection | IP20 front face conforming to IEC 60529 |
| Climatic withstand | conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device | -40…60 °C 60…70 °C with derating |
| Operating altitude | 0...3000 m |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Flame retardance | V1 conforming to UL 94 |
| Mechanical robustness | Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor open (10 Gn for 11 ms) Shocks contactor closed (15 Gn for 11 ms) |
| Height | 122 mm |
| Width | 55 mm |
| Depth | 120 mm |
| Net weight | 0.992 kg |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 6.200 cm |
| Package 1 Width | 13.700 cm |
| Package 1 Length | 15.200 cm |
| Package 1 Weight | 1.063 kg |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 9.891 kg |
| Warranty | 18 months |
|---|
Main documents
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | LC1D40ABNE |
|
Instruction sheet
|
Download |
|
Catalogue
|
Download |
|
CAD Files
|
Download |
| Environmental disclosure | Download |
Main documents
| Datasheet | Download Datasheet |
| Product datasheet | LC1D40ABNE |
|
Instruction sheet
|
Download |
|
Catalogue
|
Download |
|
CAD Files |
Download |
| Environmental disclosure | Download |
Reviews (0)
Recommended for you
-
0
Schneider LC1D65008M7 | TeSys D contactor – 4P(2 NO + 2 NC) – AC-1 <= 440 V 80 A 220 V AC 50/60 Hz coil
-
0
Schneider LC1D65AB7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 65 A – 24 V AC 50/60 Hz coil
-
0
Schneider LC1D65AF7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 65 A – 110 V AC 50/60 Hz coil
-
0
Schneider LC1D80F7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 80 A – 110 V AC 50/60 Hz coil
-
0
Schneider LC1D95M7 | TeSys D contactor – 3P(3 NO) – AC-3 – <= 440 V 95 A – 220 V AC 50/60 Hz coil
-
0
Reviews
There are no reviews yet.