Schneider LC1F185M7 | TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 185 A – coil 220 V AC
Schneider LC1F185M7 | TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 185 A – coil 220 V AC
Description
Schneider LC1F185M7 | TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 185 A – coil 220 V AC
1. Technical Specifications
-
Model: LC1F185M7
-
Series: TeSys F
-
Contactor Type: 3-pole (3 Normally Open contacts – 3NO)
-
Utilization Category: AC-3
-
Rated Operational Voltage: Up to 440V AC
-
Rated Operational Current (AC-3): 185A
-
Power Rating: Up to 90 kW (at 400V AC, 3-phase motors)
-
Coil Voltage: 220V AC
-
Coil Frequency: 50/60Hz
-
Auxiliary Contacts: Auxiliary blocks available separately
-
Mounting Options: Panel mounting with screw fixing
-
Mechanical Durability: Up to 5 million operations
-
Electrical Durability: Approx. 1 million operations (depending on load)
-
Standards Compliance: IEC 60947-4-1
2. Key Features
High Power Capacity
With a 185A current rating, this contactor is designed for large motors and high-load switching, providing robust and stable performance.
Heavy-Duty Construction
Engineered for harsh industrial conditions, the TeSys F series contactors are known for their rugged design and long operational life.
Reliable Coil Operation
Equipped with a 220V AC coil that supports both 50Hz and 60Hz frequencies, offering compatibility across multiple regions and power systems.
Expandability
Supports the addition of auxiliary contact blocks, timers, and mechanical interlocks, allowing for greater customization in control schemes.
Thermal and Magnetic Coordination
Designed to work seamlessly with Schneider thermal overload relays and circuit breakers for complete motor protection systems.
3. Typical Applications
-
Large Industrial Motors: Ideal for motors up to 90 kW (at 400V) used in heavy machinery.
-
Pumping Stations: Water treatment, irrigation, and industrial pumping systems.
-
Compressors and Fans: High-capacity HVAC equipment and industrial ventilation.
-
Crane and Hoist Control: Reliable control for large motors in lifting systems.
-
Industrial Automation: Main contactor in control panels for production lines.
-
Power Distribution Systems: Switching and protection in industrial low-voltage switchboards.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | TeSys |
|---|---|
| Range of product | TeSys F |
| Product or component type | Contactor |
| Device short name | LC1F |
| contactor application | Motor control Resistive load |
| Utilisation category | AC-3 AC-4 AC-1 |
| poles description | 3P |
| [Ue] rated operational voltage | <= 460 V DC <= 690 V AC 50/60 Hz |
| [Uc] control circuit voltage | 220 V AC 40...400 Hz |
| [Ie] rated operational current | 275 A (at <40 °C) at <= 440 V AC-1 185 A (at <55 °C) at <= 440 V AC-3 |
| [Uimp] rated impulse withstand voltage | 8 kV |
|---|---|
| [Ith] conventional free air thermal current | 275 A (at 40 °C) |
| Rated breaking capacity | 1480 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 1500 A 40 °C - 10 s 920 A 40 °C - 30 s 740 A 40 °C - 1 min 500 A 40 °C - 3 min 400 A 40 °C - 10 min |
| Associated fuse rating | 200 A aM at <= 440 V 315 A gG at <= 440 V |
| Average impedance | 0.33 mOhm - Ith 275 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
| Power dissipation per pole | 12 W AC-3 25 W AC-1 |
| Overvoltage category | III |
| power pole contact composition | 3 NO |
| Motor power kW | 90 kW at 380...400 V AC 50/60 Hz (AC-3) 100 kW at 415 V AC 50/60 Hz (AC-3) 100 kW at 440 V AC 50/60 Hz (AC-3) 110 kW at 500 V AC 50/60 Hz (AC-3) 110 kW at 660...690 V AC 50/60 Hz (AC-3) 55 kW at 220...230 V AC 50/60 Hz (AC-3) 33 kW at 400 V AC 50/60 Hz (AC-4) |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.2...0.55 Uc 40...400 Hz (at 55 °C) |
| Mechanical durability | 10 Mcycles |
| Inrush power in VA | 1070 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
| Hold-in power consumption in VA | 9.9 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
| Maximum operating rate | 2400 cyc/h 55 °C |
| Operating time | 35 ms closing (at Uc) 130 ms opening (at Uc) |
| Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 25 x 3 mm Power circuit: lugs-ring terminals 1 cable(s) 150 mm² Power circuit: connector 1 cable(s) 150 mm² Power circuit: bolted connection |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 18 N.m |
| mounting support | Plate |
| Heat dissipation | 8…9.8 W |
| motor power range | 30…50 kW at 200…240 V 3 phases 55…100 kW at 200…240 V 3 phases 55…100 kW at 380…440 V 3 phases 55…100 kW at 480…500 V 3 phases 110…220 kW at 480…500 V 3 phases |
| Motor starter type | Direct on-line contactor |
| Contactor coil voltage | 220 V AC standard |
| Standards | IEC 60947-4-1 JIS C8201-4-1 EN 60947-4-1 IEC 60947-1 EN 60947-1 |
| Product certifications | LROS (Lloyds register of shipping) RMRoS UL BV RINA CSA DNV ABS CB UKCA |
| Compatibility code | LC1F |
| Control circuit type | AC at 40...400 Hz |
| IP degree of protection | IP2X front face with shrouds conforming to IEC 60529 IP2X front face with shrouds conforming to VDE 0106 |
|---|---|
| Protective treatment | TH |
| Ambient air temperature for operation | -5…55 °C |
| Ambient air temperature for storage | -60…80 °C |
| Permissible ambient air temperature around the device | -40…70 °C |
| Height | 174 mm |
| Width | 168.5 mm |
| Depth | 181 mm |
| Operating altitude | 3000 m without derating |
| Net weight | 4.65 kg |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 21.000 cm |
| Package 1 Width | 22.000 cm |
| Package 1 Length | 23.600 cm |
| Package 1 Weight | 4.900 kg |
| Unit Type of Package 2 | P06 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 80.000 cm |
| Package 2 Width | 80.000 cm |
| Package 2 Length | 60.000 cm |
| Package 2 Weight | 67.084 kg |
| Warranty | 18 months |
|---|