Schneider METSEPM5110 | PM5110 Meter, modbus, up to 15th H, 1DO 33 alarms
Schneider METSEPM5110 | PM5110 Meter, modbus, up to 15th H, 1DO 33 alarms
Description
Schneider METSEPM5110 | PM5110 Meter, modbus, up to 15th H, 1DO 33 alarms
Product Overview: Schneider METSEPM5110 Power Meter – PM5110, Modbus, Harmonics up to 15th, 1DO, 33 Alarms
The Schneider Electric METSEPM5110 is a multifunction power meter from the PM5000 series, designed to offer enhanced visibility into electrical systems. This model features Modbus communication, harmonic analysis up to the 15th harmonic, and 33 configurable alarms, making it ideal for energy management and diagnostics.
Key Features:
-
Brand: Schneider Electric
-
Series: PM5000
-
Model Number: METSEPM5110
-
Type: Power and Energy Meter
-
Display: Backlit LCD
-
Communication: RS-485 (Modbus RTU)
-
Digital Output: 1 DO (Digital Output)
-
Alarms: 33 programmable alarms
-
Harmonics Measurement: Up to 15th harmonic
Technical Specifications:
-
Voltage Inputs: Direct or via VT, phase-to-phase & phase-to-neutral
-
Current Inputs: 1 A or 5 A (via external CTs)
-
Frequency Range: 45–65 Hz
-
Accuracy Class:
– Voltage: ±0.5%
– Current: ±0.5%
– Power: ±1%
– Energy: Class 1 (IEC 62053-21) -
Mounting: DIN rail or flush panel mounting
-
Power Supply: 100…277 V AC / 125…250 V DC
-
Operating Temp: -25°C to +70°C
-
Compliance: IEC 61010-1, IEC 61557-12, IEC 62053 standards
Functional Features:
-
Real-Time Electrical Monitoring:
– Measures voltage, current, active/reactive/apparent power, frequency, energy, and power factor -
Harmonic Analysis:
– Monitors THD (Total Harmonic Distortion) up to the 15th harmonic -
Modbus RS-485 Communication:
– Enables remote monitoring and integration with BMS or SCADA -
Alarm Management:
– 33 customizable alarms for threshold breaches and system faults -
Digital Output (1 DO):
– For pulse output or alarm signaling
Applications:
-
Sub-metering in commercial/industrial buildings
-
Power and energy monitoring in LV/MV switchboards
-
Integration with building or energy management systems
-
Harmonics and power quality diagnostics
-
Demand-side energy optimization
Benefits:
-
Modbus Ready:
– Seamless integration with most automation and monitoring systems -
High Accuracy:
– Reliable measurements for billing and analysis -
Rich Alarm Features:
– 33 alarms to detect anomalies in real-time -
Harmonics Support:
– Helps identify distortion in the network -
User-Friendly Interface:
– Intuitive navigation with a clear backlit screen
Typical Users:
-
Energy managers and facility engineers
-
Panel builders and OEMs
-
System integrators using Modbus protocols
-
Commercial and industrial energy monitoring professionals
-
Maintenance teams for predictive diagnostics
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | PowerLogic |
|---|---|
| Product name | PowerLogic PM5000 |
| Device short name | PM5110 |
| Product or component typee | Power meter |
| Power quality analysis | Up to the 15th harmonic |
|---|---|
| Device application | Power monitoring |
| Type of measurement | Current Voltage Frequency Power factor Energy Active and reactive power |
| supply voltage | 90...450 V AC 45...65 Hz 100...300 V DC |
| Network frequency | 50 Hz 60 Hz |
| [In] rated current | 1 A 5 A |
| type of network | 1P + N 3P + N 3P |
| Maximum power consumption in VA | 11 VA at 415 V |
| Ride-through time | 80 ms 120 V AC typical 100 ms 230 V AC typical 100 ms 415 V AC typical 50 ms 125 V DC typical |
| Display type | Monochrome graphic LCD |
| Display resolution | 128 x 128 pixels |
| Sampling rate | 64 samples/cycle |
| Measurement current | 50…8500 mA |
| Analogue input type | Voltage (impedance 5 MOhm) Current (impedance <= 0.3 mOhm) |
| Measurement voltage | 35…760 V AC 45...65 Hz between phases 20…440 V AC 45...65 Hz between phase and neutral |
| Frequency measurement range | 45…65 Hz |
| Number of inputs | 0 |
| Measurement accuracy | Active energy +/- 0.5 % Reactive energy +/- 2 % Active power +/- 0.5 % Apparent power +/- 0.5 % Frequency +/- 0.05 % Power factor +/- 0.5 Current +/- 0.5 % Voltage +/- 0.5 % Apparent energy +/- 0.5 % Reactive power +/- 2 % |
| Accuracy class | Class 0.5S active energy conforming to IEC 62053-22 |
| Number of outputs | 1 digital |
| Communication port protocol | Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V JBUS |
| Communication port support | RS485 |
| data recording | Time stamping Min/max of instantaneous values |
| Connections - terminals | Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 RS485 link: screw terminal block4 |
| Mounting mode | Flush-mounted |
| Mounting support | Framework |
| Standards | UL 61010-1 EN 50470-3 EN 50470-1 IEC 62053-22:2020 IEC 60529 IEC 62053-24 IEC 61557-12:2015 IEC 62053-23:2020 IEC 62052-11:2020 IEC 62052-31:2015 |
| Product certifications | CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 |
| Width | 96 mm |
| Depth | 72 mm |
| height | 96 mm |
| Net weight | 380 g |
| Electromagnetic compatibility | Voltage dips and interruptions immunity test class A conforming to IEC 61000-4-11 Limits for harmonic current emissions class A conforming to IEC 61000-3-2 Electrostatic discharge level 4 conforming to IEC 61000-4-2 Conducted RF disturbances level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency level 4 conforming to IEC 61000-4-8 Conducted and radiated emissions - test level: 150 kHz...80 MHz class B conforming to EN 55022 Immunity to conducted disturbances - test level: 150 kHz...80 MHz conforming to IEC 61000-4-6 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Surge immunity test class B conforming to IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
|---|---|
| IP degree of protection | IP54 display: conforming to IEC 60529 IP30 rear: conforming to IEC 60529 |
| Relative humidity | 5…95 % at 50 °C non-condensing |
| Pollution degree | 2 |
| Ambient air temperature for operation | -25…70 °C meter -20…70 °C display -25…-20 °C (with reduced performance) display |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | 2000 m CAT III |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.467 cm |
| Package 1 Width | 12.979 cm |
| Package 1 Length | 12.544 cm |
| Package 1 Weight | 449.0 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 30.0 cm |
| Package 2 Width | 30.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 7.19 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 288 |
| Package 3 Height | 105.0 cm |
| Package 3 Width | 80.0 cm |
| Package 3 Length | 120.0 cm |
| Package 3 Weight | 206.4 kg |