Schneider MVS40H3MF2L EasyPact | EP MVS CB 4000A 65kA 3P MF ET2 fixed manual circuit breaker
Schneider MVS40H3MF2L EasyPact
Description
Schneider MVS40H3MF2L EasyPact
Introduction
Schneider Electric, a global leader in energy management and automation solutions, offers a comprehensive range of products designed to meet the diverse needs of industries worldwide. Among these offerings is the EasyPact series, known for its reliability, efficiency, and advanced features. In this article, we will focus on the Schneider MVS40H3MF2L from the EasyPact series, exploring its specifications, features, applications, and benefits.
Understanding EasyPact Series
What is EasyPact?
EasyPact is a series of low voltage molded case circuit breakers (MCCBs) manufactured by Schneider Electric. These MCCBs are engineered to provide efficient and reliable protection for electrical installations across various industries. EasyPact products are renowned for their robustness, performance, and ease of use.
Key Features of EasyPact Products
EasyPact MCCBs are characterized by their advanced protection capabilities, compact design, and user-friendly features. They incorporate cutting-edge technologies to ensure optimal performance, safety, and ease of installation. Key features include thermal magnetic trip units, adjustable settings, and compatibility with various accessories.
Detailed Look at Schneider MVS40H3MF2L
Product Specifications
The Schneider MVS40H3MF2L is a 3-pole MCCB designed for high-performance circuit protection in industrial and commercial applications. It has a breaking capacity of 40 kA and operates at a voltage of 690V AC. it is built to withstand demanding conditions, providing reliable protection for critical electrical systems.
Design and Build Quality
Crafted with precision engineering and high-quality materials, it exhibits excellent durability and reliability. Its compact design and modular construction allow for easy installation and integration into electrical distribution panels. The MCCB’s robust build ensures long-term performance in challenging environments.
Features of Schneider MVS40H3MF2L
Advanced Protection
it offers advanced protection against overloads, short circuits, and other electrical faults. Its thermal magnetic trip units provide precise and reliable tripping characteristics, ensuring prompt isolation of faulty circuits to prevent damage and downtime. Additionally, the MCCB features adjustable settings for fine-tuning protection parameters to specific application requirements.
Intelligent Design
Schneider Electric has incorporated intelligent features into it to enhance its functionality and usability. These include ground fault protection, remote communication capabilities, and compatibility with advanced monitoring systems. The MCCB’s intelligent design enables efficient operation, maintenance, and diagnostics, contributing to improved system reliability and uptime.
User-Friendly Interface
Despite its advanced capabilities, the MVS40H3MF2L is designed with user convenience in mind. It features intuitive controls, clear indicators, and ergonomic handles for easy operation and maintenance. The MCCB’s user-friendly interface simplifies configuration and troubleshooting, minimizing downtime and enhancing productivity.
Applications of Schneider MVS40H3MF2L
Industrial Uses
In industrial settings, the Schneider MVS40H3MF2L is utilized to protect critical equipment and machinery from electrical faults. Its high breaking capacity and advanced protection features make it ideal for heavy-duty applications, such as manufacturing plants, mining operations, and oil refineries.
Commercial Uses
For commercial buildings, the MVS40H3MF2L provides reliable circuit protection for essential electrical systems, including lighting, heating, and air conditioning. Its compact size and flexible mounting options make it suitable for space-constrained environments, such as office buildings, retail stores, and healthcare facilities.
Infrastructure Projects
The MVS40H3MF2L is also deployed in infrastructure projects, such as power distribution networks, transportation systems, and renewable energy installations. Its rugged construction and wide operating range ensure dependable performance in diverse and demanding conditions, contributing to the reliability and resilience of critical infrastructure.
Benefits of Using Schneider MVS40H3MF2L
Enhanced Safety
Safety is a top priority in electrical installations, and the MVS40H3MF2L prioritizes protection against electrical hazards. Its advanced trip units and fault detection capabilities minimize the risk of accidents, ensuring the safety of personnel and assets.
Reliability
Schneider Electric is renowned for the reliability of its products, and the MVS40H3MF2L is no exception. It undergoes rigorous testing and quality assurance processes to deliver consistent performance and durability, even in harsh environments.
Efficiency
The MVS40H3MF2L contributes to the overall efficiency of electrical systems through its intelligent design and advanced features. By promptly detecting and isolating faults, it helps minimize downtime, optimize energy usage, and reduce operational costs.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | EasyPact |
|---|---|
| Product name | MVS40H |
| Device short name | MVS40H |
| Product or component typee | Circuit breaker |
| Device application | Distribution |
| Poles description | 3P |
| Protected poles description | 3P 3d |
| [In] rated current | 4000 A at 40 °C |
| Network type | AC |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Breaking capacity code | H |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| utilisation category | Category B |
| Trip unit name | ET2I |
| Trip unit technology | Electronic |
| Trip unit rating | 4000 A |
| Network frequency | 50/60 Hz |
|---|---|
| control type | Manually operated |
| Mounting mode | Fixed |
| mounting support | Base plate Rail |
| Connection position | Horizontal Vertical |
| Location of connection | Rear |
| [Ui] rated insulation voltage | 1000 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 12 kV conforming to IEC 60947-2 |
| circuit breaker CT rating | 4000 A |
| Breaking capacity | 65 kA Icu at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service breaking capacity | 65 kA (Ics) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (Ics) at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles (with maintenance) conforming to IEC 60947-2 10000 cycles (without maintenance) conforming to IEC 60947-2 |
| Electrical durability | Category B: 5000 cycles 440 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 Category B: 2500 cycles 690 V AC 50/60 Hz without maintenance conforming to IEC 60947-2 |
| Connection pitch | 115 mm without spreader |
| Contact position indicator | Yes |
| [Icm] rated short-circuit making capacity | 143 kA (Icm) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Icw] rated short-time withstand current | 65 kA (1 s) at 220...440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (1 s) at 690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA (3 s) at 440/690 V AC 50/60 Hz conforming to IEC 60947-2 |
| Trip unit protection functions | LI |
| Protection type | Instantaneous short-circuit protection Overload protection (long time) |
| fault indication | Short-circuit Internal fault Overload |
| Long time pick-up adjustment type Ir | Adjustable 9 settings |
| long time pick-up adjustment range | 0.4...1 x In |
| Long time delay adjustment type | Adjustable 9 settings |
| [tr] long-time delay adjustment range | 0.5…24 s at 6 x Ir |
| thermal memory | 20 minutes before and after tripping |
| instantaneous pick-up adjustment type Ii | Adjustable 9 settings |
| instantaneous pick-up adjustment range | 1.5...10 x Ir |
| Zone selective interlocking ZSI | With |
| current sensor rating range | 1000/4000 A |
| Maximum breaking time | 25 ms |
| maximum closing response time | 70 ms |
| height | 352 mm |
| Width | 422 mm |
| Depth | 297 mm |
| Net weight | 60 kg |
| Standards | IEC 60947-2 |
|---|---|
| product certifications | CCC CCS GOST IEC |
| Pollution degree | 4 conforming to IEC 60664-1 |
| IP degree of protection | IP40 |
| ambient air temperature for operation | -5…70 °C |
| Ambient air temperature for storage | -40…85 °C without control unit -25…85 °C with control unit |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 42.0 cm |
| Package 1 Width | 35.0 cm |
| Package 1 Length | 50.0 cm |
| Package 1 Weight | 53.5 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : MVS40H3MF2L
Main Document
Data Sheet : MVS40H3MF2L
Reviews (0)
Recommended for you
-
0
Schneider MVS16H3MF2L | EP MVS CB 1600A 65kA 3P MF ET2 fixed manual circuit breaker
-
0
Schneider MVS08H3MF2L | EP MVS CB 800A 65kA 3P MF ET2 fixed manual circuit breaker
-
0
Schneider 47383 | voltage release MN – 200..250 V DC/AC 50/60 Hz
-
0
Schneider 33671 | voltage release MN – 200..250 V DC/AC 50/60 Hz
-
0
Reviews
There are no reviews yet.