Schneider A9F85206 | Miniature circuit breaker (MCB), Acti9 iC60H, 2P, 6A, D curve, 10000A (IEC/EN 60898-1), 15kA (IEC/EN 60947-2)

Schneider A9F85206 Description

The Schneider A9F85206 is a compact, high-performance miniature circuit breaker (MCB) from the Acti9 range, designed for various electrical distribution applications. This circuit breaker is ideal for residential, commercial, and industrial settings, providing reliable protection against overloads and short circuits.

Key Features and Benefits

  1. Rated Operational Voltage: The A9F85206 operates at a voltage of 230/400V AC, making it suitable for a wide range of applications.
  2. Breaking Capacity: It boasts a breaking capacity of 6 kA, ensuring robust performance in safeguarding electrical circuits.
  3. Number of Poles: This MCB features a 2-pole configuration, enhancing its ability to manage electrical loads effectively.
  4. Tripping Curve: The device comes with a C tripping curve, which means it is designed to trip when the current flowing through it exceeds 5 to 10 times the rated current. This is particularly useful for protecting general electrical circuits with moderate inrush currents.
  5. DIN Rail Mounting: The A9F85206 is designed for easy installation on a DIN rail, streamlining the process for electricians and reducing installation time.
  6. Comprehensive Protection: It provides excellent protection for electrical circuits against overloads and short circuits, ensuring the safety of electrical installations and minimizing downtime.
  7. Compact Design: Its compact size allows for space-saving installations, making it suitable for use in confined spaces.
  8. High Durability: Built with high-quality materials, this MCB is durable and reliable, offering long-term protection for electrical systems.
  9. Standards Compliance: The A9F85206 complies with international standards, ensuring it meets rigorous safety and performance requirements.
  10. Ease of Use: The circuit breaker features a user-friendly design, with clear markings and an ergonomic handle for easy operation.

Applications

  • Residential: Ideal for use in home electrical systems to protect circuits for lighting, outlets, and appliances.
  • Commercial: Suitable for protecting electrical circuits in office buildings, retail spaces, and other commercial environments.
  • Industrial: Can be used in industrial settings to safeguard machinery and equipment from electrical faults.

Installation and Maintenance

  • Installation: The A9F85206 is designed for quick and easy installation on standard DIN rails, ensuring a hassle-free setup.
  • Maintenance: Routine checks and maintenance ensure optimal performance and longevity of the circuit breaker. Its durable construction minimizes the need for frequent replacements.

Conclusion

The Schneider A9F85206 miniature circuit breaker is a reliable and efficient solution for protecting electrical circuits in various applications. Its robust design, ease of installation, and high performance make it an excellent choice for residential, commercial, and industrial use. Ensure your electrical systems are safeguarded with the Schneider A9F85206, providing peace of mind and safety for your installations.

Additional information

brands

Schneider Electric

Specifications

Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
product or component type Miniature circuit-breaker
Device short name iC60H
poles description 2P
Number of protected poles 2
[In] rated current 6 A
Network type DC AC
Trip unit technology Thermal-magnetic
Curve code D
Breaking capacity 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2
Standards IEC 60947-2 EN 60947-2 IEC 60898-1 EN 60898-1
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 12 x In +/- 20 %
[Ics] rated service breaking capacity 15 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 21 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 15 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 15 kA 100 % conforming to EN 60947-2 - 72...125 V DC
Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
mounting mode Fixed
mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 4
Height 85 mm
Width 36 mm
Depth 78.5 mm
net weight 0.25 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
Ambient air temperature for operation -35…70 °C
Ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.3 cm
Package 1 Width 3.6 cm
Package 1 Length 8.5 cm
Package 1 Weight 216.0 g
Unit Type of Package 2 BB1
Number of Units in Package 2 6
Package 2 Height 8.1 cm
Package 2 Width 9.8 cm
Package 2 Length 22.4 cm
Package 2 Weight 1.364 kg
Unit Type of Package 3 S03
Number of Units in Package 3 66
Package 3 Height 30.0 cm
Package 3 Width 30.0 cm
Package 3 Length 40.0 cm
Package 3 Weight 15.492 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider A9F85206 | Miniature circuit breaker (MCB), Acti9 iC60H, 2P, 6A, D curve, 10000A (IEC/EN 60898-1), 15kA (IEC/EN 60947-2)”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare