Schneider A9F85206 | Miniature circuit breaker (MCB), Acti9 iC60H, 2P, 6A, D curve, 10000A (IEC/EN 60898-1), 15kA (IEC/EN 60947-2)
Description
Schneider A9F85206 | Miniature circuit breaker (MCB), Acti9 iC60H, 2P, 6A, D curve, 10000A (IEC/EN 60898-1), 15kA (IEC/EN 60947-2)
Schneider A9F85206 Description
The Schneider A9F85206 is a compact, high-performance miniature circuit breaker (MCB) from the Acti9 range, designed for various electrical distribution applications. This circuit breaker is ideal for residential, commercial, and industrial settings, providing reliable protection against overloads and short circuits.
Key Features and Benefits
- Rated Operational Voltage: The A9F85206 operates at a voltage of 230/400V AC, making it suitable for a wide range of applications.
- Breaking Capacity: It boasts a breaking capacity of 6 kA, ensuring robust performance in safeguarding electrical circuits.
- Number of Poles: This MCB features a 2-pole configuration, enhancing its ability to manage electrical loads effectively.
- Tripping Curve: The device comes with a C tripping curve, which means it is designed to trip when the current flowing through it exceeds 5 to 10 times the rated current. This is particularly useful for protecting general electrical circuits with moderate inrush currents.
- DIN Rail Mounting: The A9F85206 is designed for easy installation on a DIN rail, streamlining the process for electricians and reducing installation time.
- Comprehensive Protection: It provides excellent protection for electrical circuits against overloads and short circuits, ensuring the safety of electrical installations and minimizing downtime.
- Compact Design: Its compact size allows for space-saving installations, making it suitable for use in confined spaces.
- High Durability: Built with high-quality materials, this MCB is durable and reliable, offering long-term protection for electrical systems.
- Standards Compliance: The A9F85206 complies with international standards, ensuring it meets rigorous safety and performance requirements.
- Ease of Use: The circuit breaker features a user-friendly design, with clear markings and an ergonomic handle for easy operation.
Applications
- Residential: Ideal for use in home electrical systems to protect circuits for lighting, outlets, and appliances.
- Commercial: Suitable for protecting electrical circuits in office buildings, retail spaces, and other commercial environments.
- Industrial: Can be used in industrial settings to safeguard machinery and equipment from electrical faults.
Installation and Maintenance
- Installation: The A9F85206 is designed for quick and easy installation on standard DIN rails, ensuring a hassle-free setup.
- Maintenance: Routine checks and maintenance ensure optimal performance and longevity of the circuit breaker. Its durable construction minimizes the need for frequent replacements.
Conclusion
The Schneider A9F85206 miniature circuit breaker is a reliable and efficient solution for protecting electrical circuits in various applications. Its robust design, ease of installation, and high performance make it an excellent choice for residential, commercial, and industrial use. Ensure your electrical systems are safeguarded with the Schneider A9F85206, providing peace of mind and safety for your installations.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Device application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 |
| product or component type | Miniature circuit-breaker |
| Device short name | iC60H |
| poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 6 A |
| Network type | DC AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | D |
| Breaking capacity | 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2 |
| Standards | IEC 60947-2 EN 60947-2 IEC 60898-1 EN 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| Magnetic tripping limit | 12 x In +/- 20 % |
| [Ics] rated service breaking capacity | 15 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 21 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 15 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 15 kA 100 % conforming to EN 60947-2 - 72...125 V DC |
| Limitation class | 3 conforming to EN 60898-1 3 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| local signalling | Trip indicator |
| mounting mode | Fixed |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| 9 mm pitches | 4 |
| Height | 85 mm |
| Width | 36 mm |
| Depth | 78.5 mm |
| net weight | 0.25 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529 IP20 conforming to EN 60529 |
|---|---|
| Pollution degree | 3 conforming to EN 60947-2 3 conforming to IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.3 cm |
| Package 1 Width | 3.6 cm |
| Package 1 Length | 8.5 cm |
| Package 1 Weight | 216.0 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 8.1 cm |
| Package 2 Width | 9.8 cm |
| Package 2 Length | 22.4 cm |
| Package 2 Weight | 1.364 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 66 |
| Package 3 Height | 30.0 cm |
| Package 3 Width | 30.0 cm |
| Package 3 Length | 40.0 cm |
| Package 3 Weight | 15.492 kg |
| Warranty | 18 months |
|---|
Main Document
Main Document
Data Sheet : Download
Main Document
Data Sheet : Download
Reviews (0)
Recommended for you
-
0
Schneider A9F94140 | Miniature circuit-breaker, Acti9 iC60L, 1P, 40 A, C curve, 15000 A (IEC 60898-1), 20 kA (IEC 60947-2)
-
0
Schneider A9F94110 | Miniature circuit-breaker, Acti9 iC60L, 1P, 10 A, C curve, 15000 A (IEC 60898-1), 25 kA (IEC 60947-2)
-
0
Schneider A9F87410 | Miniature circuit-breaker, Acti9 iC60H, 4P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Schneider A9F87110 | Miniature circuit-breaker, Acti9 iC60H, 1P, 10 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)
-
0
Reviews
There are no reviews yet.