Description

Schneider A9F87216 | Miniature circuit-breaker, Acti9 iC60H, 2P, 16 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)

Schneider A9F87216 Description

The Schneider A9F87216 is a miniature circuit breaker (MCB) from the Acti9 range, designed to ensure reliable protection for electrical circuits against overloads and short circuits. This MCB is known for its efficiency, safety features, and suitability for various applications, including residential, commercial, and light industrial environments.

Key Features and Benefits

  1. High Breaking Capacity: The A9F87216 has a high breaking capacity, enabling it to safely interrupt high levels of fault current, thus providing robust protection for electrical circuits.
  2. Compact Design: Its compact size allows for straightforward installation in electrical distribution boards and panels, saving space and simplifying the wiring process.
  3. Reliable Performance: Designed for reliable performance, the A9F87216 ensures consistent protection for electrical circuits over an extended period.
  4. Easy Installation: This MCB is designed for easy installation with a user-friendly interface, reducing the time and effort required for setup.
  5. Enhanced Safety Features: The A9F87216 includes advanced safety features such as a trip-free mechanism, ensuring that the MCB cannot be forced to remain closed during a fault condition, thereby enhancing overall safety.
  6. Wide Range of Applications: Suitable for a variety of applications, including residential, commercial, and light industrial environments, offering versatile protection.
  7. Compliance with Standards: The A9F87216 complies with international standards for electrical safety and performance, ensuring reliable operation and peace of mind.
  8. Durable Construction: Made with high-quality materials, this MCB is built to withstand harsh environmental conditions, ensuring durability and long-term performance.
  9. Energy Efficiency: Designed to minimize energy consumption, making it an eco-friendly choice for modern electrical systems.

Applications

  • Residential: Ideal for protecting electrical circuits in homes, ensuring safe and reliable power distribution.
  • Commercial: Suitable for use in offices, retail spaces, and other commercial buildings, providing dependable circuit protection.
  • Light Industrial: Effective in protecting electrical circuits in light industrial environments, ensuring the safety of machinery and equipment.

Installation and Maintenance

  • Installation: The A9F87216 is designed for easy installation with clear instructions and labeling, ensuring quick and efficient setup.
  • Maintenance: Requires minimal maintenance due to its robust construction. Regular checks are recommended to ensure optimal performance.

Conclusion

The Schneider A9F87216 miniature circuit breaker is a reliable and efficient solution for protecting electrical circuits in a variety of applications. Its high breaking capacity, compact design, and advanced safety features make it an ideal choice for residential, commercial, and light industrial environments. Trust the A9F87216 to provide dependable and long-lasting protection for your electrical systems.

Additional information

brands

Schneider Electric

Specifications

Main
Device application Distribution
Range Acti9
Product name Acti9 iC60
Product or component type Miniature circuit-breaker
Device short name iC60H
poles description 2P
Number of protected poles 2
[In] rated current 16 A
Network type DC AC
Trip unit technology Thermal-magnetic
Curve code C
Breaking capacity 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 125 V DC conforming to EN/IEC 60947-2 42 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2 Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60947-2 Yes conforming to IEC 60898-1 Yes conforming to IEC 60947-2
Standards EN 60898-1 IEC 60947-2 EN 60947-2 IEC 60898-1
Quality labels NF
Complementary
Network frequency 50/60 Hz
Magnetic tripping limit 8 x In +/- 20 %
[Ics] rated service breaking capacity 15 kA 50 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to EN 60947-2 - 440 V AC 50/60 Hz 15 kA 50 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz 7.5 kA 50 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz 5 kA 50 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz 7500 A 75 % conforming to EN 60898-1 - 400 V AC 50/60 Hz 7500 A 75 % conforming to IEC 60898-1 - 400 V AC 50/60 Hz 21 kA 50 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz 21 kA 50 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz 15 kA 100 % conforming to IEC 60947-2 - 72...125 V DC 15 kA 100 % conforming to EN 60947-2 - 72...125 V DC
Limitation class 3 conforming to EN 60898-1 3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to IEC 60947-2
Contact position indicator Yes
Control type Toggle
local signalling Trip indicator
mounting mode Fixed
Mounting support DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES
9 mm pitches 4
Height 85 mm
Width 36 mm
Depth 78.5 mm
Net weight 0.25 kg
Colour White
Mechanical durability 20000 cycles
Electrical durability 10000 cycles
Connections - terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom
Earth-leakage protection Separate block
Environment
IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2 3 conforming to IEC 60947-2
Overvoltage category IV
Tropicalisation 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C
Operating altitude 0...2000 m
Ambient air temperature for operation -35…70 °C
ambient air temperature for storage -40…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.500 cm
Package 1 Width 3.500 cm
Package 1 Length 9.400 cm
Package 1 Weight 224.000 g
Unit Type of Package 2 BB1
Number of Units in Package 2 6
Package 2 Height 7.800 cm
Package 2 Width 9.700 cm
Package 2 Length 22.000 cm
Package 2 Weight 1.407 kg
Unit Type of Package 3 S03
Number of Units in Package 3 66
Package 3 Height 30.000 cm
Package 3 Width 30.000 cm
Package 3 Length 40.000 cm
Package 3 Weight 15.900 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider A9F87216 | Miniature circuit-breaker, Acti9 iC60H, 2P, 16 A, C curve, 10000 A (IEC 60898-1), 15 kA (IEC 60947-2)”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare