Description

Schneider EZC250N3250: A Comprehensive Guide

Introduction

Circuit breakers are the unsung heroes of electrical systems, ensuring safety and reliability by preventing overloads and short circuits. Among the plethora of options available, the Schneider EZC250N3250 stands out for its exceptional performance and reliability. This article delves into the details of the Schneider EZC250N3250, highlighting its features, applications, and why it might be the perfect choice for your electrical system needs.

Understanding Circuit Breakers

What is a Circuit Breaker?

A circuit breaker is an automatic electrical switch designed to protect electrical circuits from damage caused by excess current from an overload or short circuit. Its basic function is to interrupt current flow after a fault is detected.

How Do Circuit Breakers Work?

Circuit breakers detect a fault condition and interrupt the flow of electricity. Unlike fuses, which operate once and need to be replaced, a circuit breaker can be reset (either manually or automatically) to resume normal operation.

Schneider Electric: A Brief Background

History and Reputation of Schneider Electric

Schneider Electric has a rich history dating back to the 19th century. Known for its commitment to quality and innovation, Schneider has become a global leader in energy management and automation solutions.

Commitment to Quality and Innovation

Schneider Electric is dedicated to developing products that are both high-performing and environmentally friendly. The company’s commitment to innovation ensures that its products remain at the forefront of technology.

Features of Schneider EZC250N3250

Technical Specifications

The Schneider EZC250N3250 is a 3-pole circuit breaker with a rated current of 250A and a breaking capacity of 36kA. It operates on a voltage range of 690V AC, making it suitable for a variety of applications.

Unique Selling Points

This circuit breaker boasts a compact design, high breaking capacity, and ease of installation, making it a versatile choice for various electrical systems.

Design and Build Quality

Material and Construction

The Schneider EZC250N3250 is constructed using high-quality materials that ensure durability and longevity. Its robust build is designed to withstand harsh environmental conditions.

Durability and Reliability

This circuit breaker is built to last, with components that ensure consistent performance over time. Its reliability is backed by Schneider Electric’s extensive testing and quality assurance processes.

Performance and Efficiency

Current Rating and Breaking Capacity

With a current rating of 250A and a breaking capacity of 36kA, the EZC250N3250 is capable of handling significant electrical loads while maintaining safety and efficiency.

Response Time and Accuracy

The EZC250N3250 is designed for fast response times and high accuracy in detecting faults, ensuring minimal disruption to electrical systems.

Safety Features

Overload Protection

This circuit breaker provides reliable overload protection, preventing potential damage to electrical systems by automatically interrupting excessive current flow.

Short Circuit Protection

In the event of a short circuit, the Schneider EZC250N3250 acts swiftly to cut off the electrical supply, safeguarding both equipment and personnel.

Ease of Installation

Installation Process

Installing the Schneider EZC250N3250 is straightforward, thanks to its user-friendly design. Detailed instructions and mounting accessories are provided to ensure a smooth installation process.

User-Friendly Design

The compact and intuitive design of the EZC250N3250 makes it easy to handle and install, even in tight spaces or complex setups.

Applications of Schneider EZC250N3250

Industrial Applications

This circuit breaker is ideal for industrial settings, where it can manage large electrical loads and provide reliable protection for critical systems.

Additional information

brands

Schneider Electric

Specifications

Main
Range of product EasyPact
product or component type Circuit breaker
Device short name Easypact EZC250N
Circuit breaker name Easypact EZC250N
Device application Distribution
poles description 3P
Protected poles description 3t
Network type DC AC
Network frequency 50/60 Hz
[In] rated current 250 A at 40 °C
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
[Ue] rated operational voltage 550 V AC 50/60 Hz conforming to IEC 60947-2 250 V DC conforming to IEC 60947-2
Breaking capacity code N
Breaking capacity 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 110...130 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 125 V DC 1P conforming to IEC 60947-2 20 kA Icu at 250 V DC 2P conforming to IEC 60947-2 25 kA Icu at 380 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 550 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity 10 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 110/130 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 125 V DC conforming to IEC 60947-2 10 kA at 250 V DC conforming to IEC 60947-2 25 kA at 220/230/240 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 550 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 380 V AC 50/60 Hz conforming to IEC 60947-2 12.5 kA at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-2
Utilisation category Category A
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 250 A at 50 °C
Protection type Short-circuit protection Overload protection
Pollution degree 3 conforming to IEC 60664-1 3 conforming to IEC 947-1
Complementary
Control type Toggle
mounting mode Fixed
mounting support Backplate
Upside connection Front
downside connection Front
Mechanical durability 10000 cycles
Electrical durability Category A: 5000 cycles 415 V AC 50/60 Hz conforming to IEC 60947-2
Connection pitch 35 mm
local signalling Positive contact indication
Neutral protection setting Without protection
Earth-leakage protection Without
Height 165 mm
Width 105 mm
Depth 60 mm
Environment
Standards EN/IEC 60947-2 EN/IEC 60947-1 GB/T 14048.2
IP degree of protection IP20 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -35…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 12.0 cm
Package 1 Width 11.0 cm
Package 1 Length 18.2 cm
Package 1 Weight 1.583 kg
Unit Type of Package 2 S03
Number of Units in Package 2 8
Package 2 Height 30 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 2 Weight 14.09 kg
Unit Type of Package 3 P12
Number of Units in Package 3 64
Package 3 Height 50 cm
Package 3 Width 80 cm
Package 3 Length 120 cm
Package 3 Weight 124.7 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider EZC250N3250 | circuit breaker Easypact EZC250N – TMD – 250 A – 3 poles 3d”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare