Schneider TM200CE24R | controller M200 24 IO relay+Ethernet
Schneider TM200CE24R | controller M200 24 IO relay+Ethernet
Description
Schneider TM200CE24R | controller M200 24 IO relay+Ethernet
Technical Specifications:
-
Number of I/O Points: The TM200CE24R comes with a total of 24 I/O points. These include both digital inputs and digital relay outputs, making the controller suitable for a wide range of industrial applications.
-
Input/Output Type:
-
Inputs: The PLC has digital inputs, which are used for receiving on/off signals from devices like sensors, switches, or other binary systems.
-
Outputs: The relay outputs are used for controlling higher-power devices such as motors, lights, pumps, or solenoids. These outputs provide more flexibility compared to transistor outputs, as they can handle larger current and voltage ratings.
-
-
Power Supply: The TM200CE24R operates on a 24V DC power supply, which is a common standard in industrial automation systems, ensuring compatibility with a wide variety of industrial equipment and devices.
-
Ethernet Connectivity: The TM200CE24R features built-in Ethernet communication. This allows the controller to be part of an industrial network, enabling remote access, monitoring, and control. Ethernet connectivity also simplifies integration with SCADA systems, human-machine interfaces (HMIs), and other PLCs.
-
Programming: The controller is programmed using EcoStruxure Machine Expert Basic software, which supports standard IEC 61131-3 programming languages like Ladder Logic, Function Block Diagram, and Structured Text. This makes it easy for users to program and configure the PLC according to their automation needs.
-
Compact Design: The TM200CE24R is a compact controller, designed for systems where space is limited. Its small footprint allows it to be easily integrated into control panels or machinery with limited space.
-
Real-Time Control: The M200 series controllers, including the TM200CE24R, offer real-time control capabilities, making them suitable for applications where precise timing and quick response to inputs and outputs are essential.
Features:
-
Ethernet Communication: The Ethernet connectivity allows for remote access and communication with other devices in the system. It enables easy integration with higher-level systems, such as SCADA, HMI, and supervisory control systems.
-
Relay Outputs: The relay outputs provide a high level of flexibility and are suitable for controlling devices that require higher current and voltage, such as motors, actuators, and solenoids. These outputs make the TM200CE24R ideal for controlling devices that need reliable, high-power switching.
-
Compact Form Factor: With its small and compact design, the TM200CE24R is an excellent solution for applications where space is a concern. It is ideal for mounting in control panels or smaller equipment, providing powerful control in a space-saving format.
-
Easy Programming: The EcoStruxure Machine Expert Basic software is user-friendly and supports multiple programming languages, making it suitable for both beginners and experienced engineers. The software simplifies the configuration and programming process for faster deployment of automation systems.
-
Modular and Scalable: The TM200CE24R can be expanded with additional modules, allowing users to scale up their control systems as needed. Whether adding more I/O points or other specialized modules, the modularity of the M200 series makes it adaptable to a wide range of automation needs.
-
Real-Time Control: The M200 controller is designed to handle real-time control tasks, ensuring that applications requiring precise timing and coordination can operate efficiently.
-
Industrial Reliability: The TM200CE24R is built to withstand industrial environments, offering high reliability for controlling and automating processes in demanding settings.
Applications:
The Schneider TM200CE24R is ideal for various industrial automation applications, including:
-
Machine Control: It is well-suited for controlling small to medium-sized machines in sectors such as packaging, assembly, or material handling.
-
Process Control: Perfect for controlling and automating industrial processes, such as water treatment, HVAC systems, or conveyor systems.
-
Building Automation: The Ethernet connectivity allows it to control building systems such as lighting, security, HVAC, or energy management.
-
Automation Systems: Ideal for general automation applications, including controlling sensors, actuators, and small motors in a wide range of industries.
-
IoT Applications: With Ethernet connectivity, the TM200CE24R can be integrated into IoT-based systems, allowing for remote monitoring and control of devices via cloud-based platforms.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Easy Modicon M200 |
|---|---|
| Product or component type | Logic controller |
| [Us] rated supply voltage | 100...240 V AC |
| Discrete I/O number | 24 |
| Discrete input number | I2...I5: 4 fast input I0, I1, I6, I7: 4 high speed input I8...I13: 6 regular input |
| Discrete output number | 10 relay |
| Discrete input voltage | 24 V |
| Discrete input voltage type | DC |
| Discrete input current | 7 mA for input |
| Discrete input logic | Sink or source (positive/negative) type 1 conforming to IEC 61131-2 |
| Discrete output voltage | 24 V DC 220 V AC |
| Discrete output current | 2 A |
| Discrete output type | Relay normally open |
| Power consumption in VA | 52…64 VA at 100...240 V AC (with max I/O) |
| Maximum number of I/O expansion module | 4 with 128 discrete output(s) for transistor output 4 with 74 discrete output(s) for relay output |
|---|---|
| Supply voltage limits | 85…264 V |
| Network frequency | 50/60 Hz |
| Inrush current | 50 A |
| Voltage state 1 guaranteed | >= 15 V for input |
| Voltage state 0 guaranteed | <= 5 V for input |
| Input impedance | 3.3 kOhm for discrete input |
| Response time | 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input 100 µs turn-off, I2...I5 terminal(s) for fast input 35 µs turn-on, I2...I5 terminal(s) for fast input 10 ms turn-off, Q0...Q9 terminal(s) for relay output 10 ms turn-on, Q0...Q9 terminal(s) for relay output 100 µs turn-off, I8...I13 terminal(s) for regular input 35 µs turn-on, I8...I13 terminal(s) for regular input |
| Configurable filtering time | 0 ms for input 3 ms for input 12 ms for input |
| Output voltage limits | 30 V DC 250 V AC |
| Maximum current per output common | 4 A at COM 2 4 A at COM 0 4 A at COM 1 |
| Electrical durability | 100000 cycles AC-12, 240 V, 480 VA, resistive 100000 cycles DC-12, 24 V, 48 W, resistive |
| Switching frequency | 0.1 Hz with maximum load |
| Mechanical durability | 20000000 cycles for relay output |
| Minimum load | 10 mA at 5 V DC for relay output |
| Memory capacity | 512 byte internal flash for backup of programs |
| Data storage equipment | 32 GB micro SD card (optional) |
| Battery type | BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s) |
| Backup time | 3 years at 25 °C (by interruption of power supply) |
| Execution time for 1 KInstruction | 0.3 ms for event and periodic task |
| Execution time per instruction | 0.2 µs Boolean |
| Exct time for event task | 60 µs response time |
| Clock drift | <= 90 s/month at 25 °C |
| Regulation loop | Adjustable PID regulator up to 14 simultaneous loops |
| Control signal type | Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) Pulse/direction at 100 kHz for fast input (HSC mode) Single phase at 100 kHz for fast input (HSC mode) CW/CCW at 100 kHz for fast input (HSC mode) |
| Counting input number | 4 fast input (HSC mode) at 100 kHz 32 bits |
| Integrated connection type | USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with terminal block connector and RS485 interface Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface Isolated serial link serial 2 with terminal block connector and RS485 interface |
| Transmission rate | 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 12 Mbit/s for USB 10/100 Mbit/s for bus length of 100 m for Ethernet Modbus TCP/IP |
| Communication port protocol | USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network Ethernet Modbus TCP/IP: Modbus TCP/IP client/server |
| Local signalling | 1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED (green) for SL1 1 LED per channel (green) for I/O state 2 LEDs (green) for communication (LK/ACT 10/100) |
| Electrical connection | Mini B USB 2.0 connectorfor a programming terminal RJ45 connectorfor connecting Ethernet network removable screw terminal blockfor inputs removable screw terminal blockfor outputs removable screw terminal block, 4 terminal(s) for connecting the serial link1 removable screw terminal block, 3 terminal(s) for connecting the 100-240 V AC power supply |
| Maximum cable distance between devices | Unshielded cable: <50 m for input Shielded cable: <10 m for fast input Shielded cable: <10 m for high speed input Unshielded cable: <150 m for output |
| Insulation | Non-insulated between inputs Between output and internal logic at 1780 V AC Between output groups at 1780 V AC Between supply and internal logic at 1780 V AC Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Between input groups at 500 V AC |
| Sensor power supply | 24 V DC at 250 mA supplied by the controller |
| Marking | CE |
| Mounting support | Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715 |
| Height | 90 mm |
| Depth | 70 mm |
| Width | 130 mm |
| Net weight | 0.413 kg |
| IP degree of protection | IP20 with protective cover in place |
|---|---|
| Product certifications | RCM IACS E10 cULus CSA |
| Standards | IEC 61010-2-201 IEC 61131-2 |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m conforming to IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 1 kV (serial link) conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (power lines (AC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (relay output) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (I/O) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (shielded cable) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 0.5 kV (power lines (DC)) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (AC)) conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 Conducted emission - test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Conducted emission - test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to IEC 55011 Radiated emission - test level: 40 dBμV/m QP class A (10 m) conforming to IEC 55011 Radiated emission - test level: 47 dBμV/m QP class A (10 m) conforming to IEC 55011 Electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4 |
| Shock resistance | 15 gn for 11 ms 30 gn for 6 ms |
| Immunity to microbreaks | 10 ms |
| Vibration resistance | 3.5 mm at 5…8.4 Hz on symmetrical rail 1 gn at 8.4…150 Hz on symmetrical rail 3.5 mm at 5…8.7 Hz on panel mounting 2 gn at 8.7…150 Hz on panel mounting |
| Relative humidity | 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) |
| Ambient air temperature for operation | 0…55 °C (horizontal installation) |
| Ambient air temperature for storage | -25…70 °C |
| Pollution degree | <= 2 |
| Operating altitude | 0...2000 m |
| Storage altitude | 0…3000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.497 cm |
| Package 1 Width | 13.655 cm |
| Package 1 Length | 14.312 cm |
| Package 1 Weight | 609.5 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 12 |
| Package 2 Height | 30 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 7810 g |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 288 |
| Package 3 Height | 95 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 196440 g |