Description

Schneider LV510302 | circuit breaker EasyPact CVS100B, 25 kA at 415 VAC, 32 A rating thermal magnetic TM-D trip unit, 3P 3d

Technical Specifications

  • Model: Schneider LV510302 | EasyPact CVS100B
  • Rated Current: 32A
  • Breaking Capacity: 25 kA at 415V AC
  • Poles: 3P (Three-Pole)
  • Trip Unit Type: Thermal-Magnetic TM-D
  • Voltage Rating: 415V AC
  • Mounting Type: Fixed
  • Protection Type: Overload & Short Circuit
  • Standard Compliance: IEC 60947-2
  • Operating Temperature: -25°C to 70°C

Key Features

  1. High-Performance Protection
    • Thermal-Magnetic TM-D Trip Unit offers dual protection:
      Thermal protection for overloads.
      Magnetic protection for short circuits.
    • 25 kA breaking capacity at 415V AC ensures safety in demanding electrical environments.
  2. Durability & Reliability
    • Built to withstand harsh conditions in industrial and commercial applications.
    • Long lifespan with minimal maintenance requirements.
  3. Ease of Installation & Use
    • Three-pole (3P) design for effective three-phase power distribution.
    • Compact and user-friendly design for seamless integration into electrical panels.
  4. Compliance with Safety Standards
    • Certified under IEC 60947-2, ensuring global safety and performance reliability.

Applications

The Schneider LV510302 | EasyPact CVS100B circuit breaker is ideal for various applications, including:

Industrial Facilities – Protecting machinery and electrical panels from faults.
Commercial Buildings – Ensuring safe and efficient power distribution.
Residential Installations – Providing enhanced protection for home electrical circuits.
Power Distribution Systems – Used in switchgear and distribution boards.

Additional information

brands

Schneider Electric

Specifications

Main
Range EasyPact
Range of product EasyPact CVS100...250
product name EasyPact CVS
Device short name CVS100B
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3D
Earth leakage protection (Vigi add on) Without
[In] rated current 32 A at 40 °C
network type AC
Utilisation category Category A
[Icu] Breaking capacity 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 32 A at 40 °C
Protection type Overload protection (thermal) Short-circuit protection (magnetic)
Complementary
[Uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
Network frequency 50/60 Hz
Breaking capacity code B
[Ics] rated service breaking capacity 15 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability 30000 cycles
Electrical durability 12000 cycles 415 V In conforming to IEC 60947-2
Control type Toggle
Thermal protection adjustment range 22.4…32 A
Long time pick-up adjustment type Ir Adjustable
Long time pick-up adjustment range 0.7...1 x In
Long time delay adjustment type Fixed
Instantaneous pick-up adjustment type Ii Fixed
Instantaneous pick-up adjustment range 400 A
Contact position indicator Yes
Mounting support Backplate
Mounting mode Fixed
Upside connection Front
Downside connection Front
Connections - terminals Screw connection
Connection pitch 35 mm
Compatibility code CVS100
Width 105 mm
Depth 86 mm
Height 161 mm
Product weight 1.5 kg
Environment
Standards IEC 60947-2 EN 60947-2
Product certifications IEC GOST
Electrical shock protection class Class II
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.500 cm
Package 1 Width 14.000 cm
Package 1 Length 19.000 cm
Package 1 Weight 1.702 kg
Unit Type of Package 2 S03
Number of Units in Package 2 8
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 14.036 kg
Unit Type of Package 3 P12
Number of Units in Package 3 64
Package 3 Height 45.000 cm
Package 3 Width 80.000 cm
Package 3 Length 120.000 cm