Schneider ATV320U07M2C412 Altivar Solar | Variable speed drive, Altivar Solar, 0.75kW, 200 to 240V, 1 phase, compact
Schneider ATV320U07M2C412 Altivar Solar | Variable speed drive, Altivar Solar, 0.75kW, 200 to 240V, 1 phase, compact
Easy scalability of your Automation system
Description
Schneider ATV320U07M2C412 Altivar Solar | Variable speed drive, Altivar Solar, 0.75kW, 200 to 240V, 1 phase, compact
The Schneider Altivar ATV320U07M2C412 is a compact variable speed drive (VSD) from the Altivar Solar range, designed for efficient operation of small-scale solar pumping systems. It is engineered to control motors up to 0.75 kW on a single-phase supply ranging from 200 to 240V.
Key Features and Benefits
This drive is built with advanced technology to maximize the performance of a solar-powered pump. A key feature is its Maximum Power Point Tracking (MPPT), an intelligent algorithm that continuously optimizes the pump’s speed to draw the most power available from the solar panels at any given time, ensuring maximum water flow even under fluctuating sunlight.
Its compact, book-style form factor allows for easy and space-saving installation in control cabinets. It’s a robust device with a high degree of resistance to environmental factors, making it suitable for use in demanding conditions. The drive includes integrated safety functions like Safe Torque Off (STO), which prevents accidental motor startup, and also offers specific protections for pumping applications, such as dry-run protection to prevent damage to the pump when the water source is empty. The drive can also be configured to operate on a conventional AC grid, providing a reliable backup power source.
Primary Applications
The Schneider Altivar ATV320U07M2C412 is a perfect fit for a variety of small-scale, off-grid water pumping needs. Its main applications include:
Small-scale agricultural irrigation for crops and gardens.
Residential and domestic water supply in remote homes and communities.
Filling water storage tanks in locations without a stable grid connection.
Livestock watering in rural areas.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range of product | Altivar Solar |
|---|---|
| Product or component type | Variable speed drive |
| Product specific application | Pumping applications |
| Variant | Standard version |
| Format of the drive | Compact |
| Mounting mode | Wall mount |
| Communication port protocol | Modbus serial CANopen |
| Option card | Communication module, Ethernet IP/Modbus TCP |
| [Us] rated supply voltage | 200...240 V - 15...10 % |
| nominal output current | 4.8 A |
| Motor power kW | 0.75 kW for heavy duty |
| EMC filter | Class C2 EMC filter integrated |
| IP degree of protection | IP20 |
| Discrete input number | 7 |
|---|---|
| Discrete input type | STO safe torque off, 24 V DC, impedance: 1.5 kOhm DI1...DI6 logic inputs, 24 V DC (30 V) DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V) |
| Discrete input logic | Positive logic (source) Negative logic (sink) |
| Discrete output number | 3 |
| Discrete output type | Open collector DQ+ 0…1 kHz 30 V DC 100 mA Open collector DQ- 0…1 kHz 30 V DC 100 mA |
| Analogue input number | 3 |
| Analogue input type | AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits |
| Analogue output number | 1 |
| Analogue output type | Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits |
| Relay output number | 2 |
| Relay output type | Configurable relay logic R1A 1 NO electrical durability 100000 cycles Configurable relay logic R1B 1 NC electrical durability 100000 cycles Configurable relay logic R1C Configurable relay logic R2A 1 NO electrical durability 100000 cycles Configurable relay logic R2C |
| Maximum switching current | Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC |
| Minimum switching current | Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC |
| Method of access | Slave CANopen |
| Number of addresses | 1…247 1…127 |
| Data format | 8 bits, configurable odd, even or no parity |
| Type of polarization | No impedance |
| 4 quadrant operation possible | True |
| Asynchronous motor control profile | Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f Flux vector control without sensor - Energy Saving Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor |
| Maximum output frequency | 0.599 kHz |
| Acceleration and deceleration ramps | Linear U S CUS Ramp switching Acceleration/deceleration ramp adaptation Acceleration/deceleration automatic stop with DC injection Automatic adaptation of ramp if braking capacity exceeded, by using resistor Linear adjustable separately from 0.01 to 6000 s |
| Motor slip compensation | Automatic whatever the load Adjustable 0...300 % Not available in voltage/frequency ratio (2 or 5 points) |
| Switching frequency | 2...16 kHz adjustable 4...16 kHz with derating factor |
| Nominal switching frequency | 4 kHz |
| Braking to standstill | By DC injection |
| Brake chopper integrated | True |
| Line current | 4 A at 200 V (heavy duty) 8.4 A at 240 V (heavy duty) |
| Maximum input current | 10 A |
| Maximum output voltage | 240 V |
| Apparent power | 2.0 kVA at 240 V (heavy duty) |
| Maximum transient current | 7.2 A during 60 s |
| Short-circuit protection | thermal protection |
| Network frequency | 50...60 Hz |
| Relative symmetric network frequency tolerance | 5 % |
| Prospective line Isc | 1 kA |
| Base load current at high overload | 33.0 A |
| Power dissipation in W | Self-cooled: 45.0 W at 200 V, switching frequency 4 kHz |
| Electrical connection | Screw terminal, clamping capacity: 0.5...1.5 mm² for analog input Screw terminal for analog output Screw terminal |
| With safety function Safely Limited Speed (SLS) | True |
| With safety function Safe brake management (SBC/SBT) | False |
| With safety function Safe Operating Stop (SOS) | False |
| With safety function Safe Position (SP) | False |
| With safety function Safe programmable logic | False |
| With safety function Safe Speed Monitor (SSM) | False |
| With safety function Safe Stop 1 (SS1) | True |
| With sft fct Safe Stop 2 (SS2) | False |
| With safety function Safe torque off (STO) | True |
| With safety function Safely Limited Position (SLP) | False |
| With safety function Safe Direction (SDI) | False |
| Protection type | Input phase breaks: drive Overcurrent between output phases and earth: drive Overheating protection: drive Short-circuit between motor phases: drive Thermal protection: drive |
| Width | 72.0 mm |
| Height | 143.0 mm |
| Depth | 138.0 mm |
| Net weight | 1.1 kg |
| Power factor | 0.55 at 230 V |
| Braking torque | 170 % with braking resistor |
| Local signalling | 1 LED (red) for drive fault 1 LED (red) for CANopen error 1 LED (green) for CANopen run |
| Transient overtorque | 170…200 % of nominal motor torque |
| Operating position | Vertical +/- 10 degree |
|---|---|
| Product certifications | CE UR UKCA RCM |
| Marking | CE UR UKCA RCM |
| Standards | IEC 61800-5-1 |
| Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
| Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
| Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
| Permitted relative humidity (during operation) | Class 3K5 according to EN 60721-3 |
| Overvoltage category | II |
| Regulation loop | Adjustable PID regulator |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| Pollution degree | 2 |
| Ambient air transport temperature | -25…70 °C |
| Ambient air temperature for operation | -10…50 °C without derating 50…60 °C with derating factor |
| Ambient air temperature for storage | -25…70 °C |
| Operating altitude | 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 12.300 cm |
| Package 1 Width | 19.100 cm |
| Package 1 Length | 19.700 cm |
| Package 1 Weight | 1.284 kg |
| Unit Type of Package 2 | S06 |
| Number of Units in Package 2 | 45 |
| Package 2 Height | 75.000 cm |
| Package 2 Width | 60.000 cm |
| Package 2 Length | 80.000 cm |
| Package 2 Weight | 72.850 kg |
date sheet
date sheet
date sheet
Reviews (0)
Recommended for you
Schneider NSYSFC86 | Spacial SF bottom and top frame – 800×600 mm
Schneider NSYSFC66 | Spacial SF bottom and top frame – 600×600 mm
Schneider NSYCRNG1210300D | Spacial CRNG dbl plain door w/o mount.plate. H1200xW1000xD300 IP55 IK10 RAL7035
Schneider NSYCRNG128300 | Spacial CRNG plain door w/o mount.plate. H1200xW800xD300 IP66 IK10 RAL7035
-
0
Schneider LC1G265KUEN | High power contactor, TeSys Giga, 3 pole (3NO), AC-3 <=440V 265A, standard version, 100…250V wide band AC/DC coil
-
0
Reviews