Description

Schneider LC1D40004P7 Contactor: The Ultimate Solution for Industrial Electrical Control

Schneider LC1D40004P7 | TeSys D Contactor – 4P (4 NO) – 60A – 230V AC Coil

1. General Description

The Schneider LC1D40004P7 is a high-performance TeSys D contactor designed for power switching and industrial control applications. It features four normally open (4 NO) poles, making it suitable for AC-1 applications up to 60A at ≤ 440V. Equipped with a 230V AC 50/60 Hz coil, this contactor ensures efficient and reliable switching for various industrial and commercial uses.

2. Technical Specifications

  • Product Series: TeSys D

  • Contactor Type: 4-pole (4 NO)

  • Utilization Category: AC-1

  • Rated Operational Voltage: ≤ 440V

  • Rated Current (AC-1): 60A

  • Coil Voltage: 230V AC, 50/60 Hz

  • Electrical Durability: Up to 1 million operations

  • Mechanical Durability: Up to 10 million operations

  • Mounting Type: DIN rail or panel mounting

  • Operating Temperature Range: -5°C to +60°C

  • Certifications: CE, UL, IEC

3. Key Features

  • Reliable Coil Operation: Works with 230V AC at 50/60 Hz, ensuring compatibility with standard industrial power supplies.

  • High Load Capacity: Handles 60A in AC-1 applications, ideal for resistive and inductive loads.

  • Compact and Modular Design: Optimized for easy integration into industrial control panels.

  • Long Operational Life: Built for durability, minimizing maintenance and replacement costs.

  • Flexible Mounting Options: Supports DIN rail and panel mounting for quick and easy installation.

4. Applications

  • General power distribution and control

  • Industrial automation and machine control

  • Heating, ventilation, and air conditioning (HVAC) systems

  • Switching of resistive and inductive loads

  • Lighting control and power management

5. Compliance and Standards

  • IEC 60947-4-1 (Low-voltage switchgear and controlgear)

  • CE Certified

  • UL Listed

  • RoHS Compliant

6. Conclusion

The Schneider LC1D40004P7 TeSys D Contactor is a robust and efficient solution for power switching applications. With a 230V AC coil, 60A current rating, and four normally open contacts, it ensures high reliability, long service life, and easy installation in industrial and commercial electrical systems

Additional information

brands

Schneider Electric

Specifications

Main
Range of product TeSys Deca
Product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1 AC-3 AC-3e AC-4
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
[Ie] rated operational current 60 A (at <60 °C) AC AC-1 for power circuit
[Uc] control circuit voltage 230 V AC 50/60 Hz
Complementary
Compatibility code LC1D
Pole contact composition 4 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for control circuit 60 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for control circuit conforming to IEC 60947-5-1 800 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 800 A at 440 V for power circuit conforming to IEC 60947
Associated fuse rating 10 A gG for control circuit conforming to IEC 60947-5-1 80 A gG at <= 690 V coordination type 1 for power circuit 80 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.5 mOhm - Ith 60 A 50 Hz for power circuit
Power dissipation per pole 5.4 W AC-1
[Ui] rated insulation voltage Control circuit: 600 V CSA certified Control circuit: 600 V UL certified Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Control circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-1
Overvoltage category III
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 6000000 cycles
Control circuit type AC at 50/60 Hz standard
Coil technology Without built-in bidirectional peak limiting diode suppressor
Control circuit voltage limits 0.3...0.6 Uc (60 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (60 °C):operational AC 50 Hz 0.85...1.1 Uc (60 °C):operational AC 60 Hz
Inrush power in VA 140 VA cos phi 0.75 (at 20 °C) 160 VA cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50/60 Hz for control circuit
Operating time 12...26 ms closing 4...19 ms opening
Maximum operating rate 3600 cyc/h 60 °C
Connections - terminals Control circuit: screw clamp terminal 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminal 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminal 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminal 1 1…35 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminal 2 1…25 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminal 2 1…35 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminal - with screwdriver Philips No 2 Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 8 mm
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
Minimum switching voltage 17 V for control circuit
Minimum switching current 5 mA for control circuit
Insulation resistance > 10 MOhm for control circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts
Mounting support Rail Plate
Environment
Standards CSA C22.2 No 14 EN 60947-5-1 UL 508 IEC 60947-4-1 EN 60947-4-1 IEC 60947-5-1
Product certifications LROS (Lloyds register of shipping) GL DNV UL CSA RINA BV CCC GOST UKCA
IP degree of protection IP2X conforming to IEC 60529 IP2X conforming to VDE 0106
Protective treatment TH (pollution degree 3) conforming to IEC 60068
Permissible ambient air temperature around the device -5…60 °C -40…70 °C at Uc
Operating altitude 3000 m without derating
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Shocks contactor open (8 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)
Height 127 mm
Width 85 mm
Depth 125 mm
Net weight 1.44 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 11.2 cm
Package 1 Width 13.5 cm
Package 1 Length 15.5 cm
Package 1 Weight 1.467 kg
Unit Type of Package 2 S02
Number of Units in Package 2 5
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 7.65 kg
Contractual warranty
Warranty 18 months

Main documents

Main documents

Datasheet Download Datasheet
Product datasheet LC1D40004P7 
Instruction sheet
Download
CAD Files Download

Main documents

Datasheet Download Datasheet
Product datasheet LC1D40004P7 
Instruction sheet
Download
CAD Files Download

Reviews (0)

Be the first to review “Schneider LC1D40004P7 Contactor | TeSys LC1-D – 4 poles – AC-1 440V 60 A – coil 230 V AC”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare