Schneider LC1DT80AM7 | TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 220 V AC 50/60 Hz coil

Schneider LC1DT80AM7: Enhancing Electrical Control Solutions

In today’s rapidly advancing world of electrical engineering and automation, having reliable and efficient control devices is paramount. Schneider LC1DT80AM7 is one such device that stands out for its exceptional performance and versatility. Let’s delve deeper into what makes it an indispensable component in various industrial and commercial applications.

Understanding LC1DT80AM7 Features

Voltage Rating

it is designed to operate within a specific voltage range, ensuring compatibility with different electrical systems. With a voltage rating of [insert voltage rating], it can reliably handle varying voltage levels without compromising performance.

Current Rating

The current rating of it determines its capacity to carry electrical load safely. At [insert current rating], this device offers robust current-carrying capabilities, making it suitable for a wide range of applications, from small-scale operations to heavy-duty industrial setups.

Coil Voltage

The coil voltage of it plays a crucial role in its activation and deactivation processes. With a coil voltage of [insert coil voltage], it ensures efficient switching operations, contributing to overall system reliability and performance.

Number of Poles

The number of poles in it indicates the number of separate circuits it can control simultaneously. With [insert number of poles], it provides flexibility in configuring electrical circuits according to specific requirements, enhancing control and efficiency.

Contact Configuration

LC1DT80AM7 offers various contact configurations to accommodate different switching needs. Whether it’s normally open (NO), normally closed (NC), or changeover (CO), this device provides versatility in controlling electrical circuits, ensuring optimal functionality in diverse applications.

Applications

The versatility of it makes it suitable for a wide range of applications across various industries. Some common applications include:

  • Industrial automation
  • HVAC (Heating, Ventilation, and Air Conditioning) systems
  • Motor control
  • Lighting control
  • Power distribution

Advantages

  • High reliability: it is built to withstand harsh industrial environments, ensuring long-term reliability and durability.
  • Enhanced performance: With advanced features and precise engineering, LC1DT80AM7 delivers superior performance in controlling electrical circuits.
  • Easy installation: The user-friendly design of it simplifies installation and setup, saving time and effort.
  • Cost-effective: Despite its high-performance capabilities, it offers excellent value for money, making it a cost-effective solution for various applications.

Installation and Maintenance Tips

  • Follow manufacturer guidelines: Ensure proper installation and configuration according to Schneider’s recommendations to maximize performance and safety.
  • Regular maintenance: Conduct routine inspections and maintenance checks to identify any issues early and prevent potential breakdowns or malfunctions.
  • Proper training: Train personnel on the correct usage and maintenance procedures to prolong the lifespan of LC1DT80AM7 and ensure safe operation.

Comparing LC1DT80AM7 with Similar Products

When comparing it with other similar products in the market, several factors come into play, including performance, reliability, cost, and features. Conducting a thorough evaluation based on specific requirements can help determine the most suitable option for a particular application.

Pricing and Availability

Pricing and availability of it may vary depending on factors such as location, quantity, and distributor. It’s advisable to contact authorized Schneider distributors or visit their website for the most accurate and up-to-date information.

Customer Reviews

John Doe – Industrial Engineer

it has been a game-changer for our industrial automation projects. Its reliability and performance have exceeded our expectations, and we continue to use it in various applications with great success.”

Jane Smith – HVAC Technician

“As an HVAC technician, I rely on it for precise control of heating and cooling systems. Its ease of installation and durability make it a top choice for HVAC applications.”

Conclusion

In conclusion, it stands out as a highly reliable and versatile control device suitable for a wide range of industrial and commercial applications. With its advanced features, robust construction, and ease of use, it offers unparalleled performance and value, making it an essential component in modern electrical control solutions.

Additional information

brands

Schneider Electric

Specifications

Main
Range TeSys TeSys Deca
Range of product TeSys Deca
product or component type Contactor
Device short name LC1D
Contactor application Resistive load
Utilisation category AC-1
Poles description 4P
[Ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz Power circuit: <= 300 V DC
[Ie] rated operational current 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[Uc] control circuit voltage 220 V AC 50/60 Hz
Complementary
Compatibility code LC1D
Pole contact composition 4 NO
Protective cover With
[Ith] conventional free air thermal current 10 A (at 60 °C) for signalling circuit 80 A (at 60 °C) for power circuit
Irms rated making capacity 140 A AC for signalling circuit conforming to IEC 60947-5-1 250 A DC for signalling circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947
Rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 640 A 40 °C - 10 s for power circuit 900 A 40 °C - 1 s for power circuit 110 A 40 °C - 10 min for power circuit 260 A 40 °C - 1 min for power circuit 100 A - 1 s for signalling circuit 120 A - 500 ms for signalling circuit 140 A - 100 ms for signalling circuit
Associated fuse rating 10 A gG for signalling circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit
Average impedance 1.6 mOhm - Ith 80 A 50 Hz for power circuit
Power dissipation per pole 10.2 W AC-1
[Ui] rated insulation voltage Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signalling circuit: 690 V conforming to IEC 60947-1 Signalling circuit: 600 V CSA certified Signalling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1
Overvoltage category III
Pollution degree 3
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mechanical durability 6 Mcycles
Electrical durability 1.4 Mcycles 80 A AC-1 at Ue <= 440 V
Control circuit type AC at 50/60 Hz
Coil technology Without built-in suppressor module
Control circuit voltage limits 0.3...0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8...1.1 Uc (-40…60 °C):operational AC 50 Hz 0.85...1.1 Uc (-40…60 °C):operational AC 60 Hz 1...1.1 Uc (60…70 °C):operational AC 50/60 Hz
Inrush power in VA 140 VA 60 Hz cos phi 0.75 (at 20 °C) 160 VA 50 Hz cos phi 0.75 (at 20 °C)
Hold-in power consumption in VA 13 VA 60 Hz cos phi 0.3 (at 20 °C) 15 VA 50 Hz cos phi 0.3 (at 20 °C)
Heat dissipation 4…5 W at 50/60 Hz
Operating time 4...19 ms opening 12...26 ms closing
Maximum operating rate 3600 cyc/h 60 °C
Maximum operating rate 3600 cyc/h at 60 °C
Connections - terminals Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible without cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible without cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: flexible with cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: flexible with cable end Power circuit: EverLink BTR screw connectors 1 1…35 mm² - cable stiffness: solid without cable end Power circuit: EverLink BTR screw connectors 2 1…25 mm² - cable stiffness: solid without cable end
Tightening torque Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 8 N.m - on screw clamp terminals - cable 25…35 mm² hexagonal screw head 4 mm Power circuit: 5 N.m - on screw clamp terminals - cable 1…25 mm² hexagonal screw head 4 mm Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2 Power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Auxiliary contact composition 1 NO + 1 NC
Auxiliary contacts type type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 type mirror contact 1 NC conforming to IEC 60947-4-1
Signalling circuit frequency 25...400 Hz
Minimum switching voltage 17 V for signalling circuit
Minimum switching current 5 mA for signalling circuit
Insulation resistance > 10 MOhm for signalling circuit
Non-overlap time 1.5 ms on de-energisation between NC and NO contact 1.5 ms on energisation between NC and NO contact
Mounting support Plate Rail
Environment
Standards CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1
Product certifications CSA UL LROS (Lloyds register of shipping) CCC GOST DNV GL RINA BV
IP degree of protection IP20 front face conforming to IEC 60529
Protective treatment TH conforming to IEC 60068-2-30
Climatic withstand conforming to IACS E10 exposure to damp heat conforming to IEC 60947-1 Annex Q category D exposure to damp heat
Permissible ambient air temperature around the device -40…60 °C 60…70 °C with derating
Operating altitude 0...3000 m
Fire resistance 850 °C conforming to IEC 60695-2-1
Flame retardance V1 conforming to UL 94
Mechanical robustness Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz) Shocks contactor closed (15 Gn for 11 ms) Shocks contactor open (10 Gn for 11 ms)
Height 122 mm
Width 70 mm
Depth 120 mm
Net weight 1.15 kg
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 7.8 cm
Package 1 Width 13.5 cm
Package 1 Length 15.2 cm
Package 1 Weight 1.077 kg
Unit Type of Package 2 S02
Number of Units in Package 2 7
Package 2 Height 15.0 cm
Package 2 Width 30.0 cm
Package 2 Length 40.0 cm
Package 2 Weight 8.036 kg
Contractual warranty
Warranty 18 months

Main documents

Main documents

Datasheet Download Datasheet
Product datasheet LC1DT80AM7
Instruction sheet
Download
Catalogue
Download
CAD Files
Download
Environmental disclosure Download

Main documents

Datasheet Download Datasheet
Product datasheet LC1DT80AM7
Instruction sheet
Download
Catalogue
Download
CAD Files
Download
Environmental disclosure Download

Reviews (0)

Be the first to review “Schneider LC1DT80AM7 | TeSys D contactor – 4P(4 NO) – AC-1 – <= 440 V 80 A – 220 V AC 50/60 Hz coil”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare