Description

Schneider ATS480D88Y | Soft starter, Altistart 480, 88A, 208 to 690V AC, control supply 110 to 230V AC

Schneider ATS480D88Y | Soft Starter Overview

The Schneider ATS480D88Y is a soft starter from the Altistart 480 series, designed to provide smooth motor acceleration and deceleration while reducing mechanical and electrical stress. This device is ideal for industrial applications where controlled motor starting is required.

1. General Specifications

  • Product Name: Schneider ATS480D88Y

  • Series: Altistart 480

  • Function: Soft Starter

  • Rated Current: 88A

  • Operating Voltage: 208V to 690V AC

  • Control Supply Voltage: 110V to 230V AC

2. Features & Benefits

Soft Motor Start & Stop: Reduces wear and tear on mechanical components.
Wide Voltage Compatibility: Supports various power supply configurations.
Energy Efficiency: Minimizes inrush current, optimizing power usage.
Integrated Motor Protection: Guards against overloads, overheating, and voltage imbalances.
User-Friendly Interface: Simple setup and monitoring via an intuitive digital display.
Industrial Network Integration: Supports communication protocols for seamless control.

3. Applications

🔹 Pumps & Compressors – Prevents water hammer effects and pressure surges.
🔹 Fans & Blowers – Smooth acceleration for HVAC and ventilation systems.
🔹 Conveyors & Material Handling – Ensures steady motor operation and load control.
🔹 Industrial Machinery – Ideal for sawmills, crushers, and mixers.
🔹 Water Treatment Plants – Reliable operation in critical infrastructure.

4. Protection & Safety

  • Overload Protection – Prevents damage due to excessive current.

  • Short Circuit Protection – Enhances electrical safety.

  • Overtemperature Protection – Avoids overheating of the system.

  • Phase Loss & Imbalance Detection – Ensures stable motor operation.

Additional information

brands

Schneider Electric

Specifications

Main
Range of Product Altivar Soft Starter ATS480
Product or Component Type Soft starter
Product destination Asynchronous motors
Product Specific Application Process and infrastructures
Device short name ATS480
Phase 3 phase
Utilisation category AC-3A AC-53A
Ue power supply voltage 208...690 V - 15...10 %
power supply frequency 50...60 Hz - 20...20 %
[Ie] rated operational current Normal duty 88.0 A 104 °F (40 °C))
rated current in heavy duty 75.0 A at 104 °F (40 °C) heavy duty
Torque control True
IP Degree of Protection IP20
Motor power kW 22.0 kW 230 V in the motor supply line normal duty 18.5 kW 230 V in the motor supply line heavy duty 45.0 kW 400 V in the motor supply line normal duty 37.0 kW 400 V in the motor supply line heavy duty 45.0 kW 440 V in the motor supply line normal duty 37.0 kW 440 V in the motor supply line heavy duty 55.0 kW 500 V in the motor supply line normal duty 45.0 kW 500 V in the motor supply line heavy duty 55.0 kW 525 V in the motor supply line normal duty 45.0 kW 525 V in the motor supply line heavy duty 75.0 kW 660 V in the motor supply line normal duty 55.0 kW 660 V in the motor supply line heavy duty 75.0 kW 690 V in the motor supply line normal duty 55.0 kW 690 V in the motor supply line heavy duty 45.0 kW 230 V to the motor delta terminals normal duty 37.0 kW 230 V to the motor delta terminals heavy duty 75.0 kW 400 V to the motor delta terminals normal duty 55.0 kW 400 V to the motor delta terminals heavy duty
Maximum Horse Power Rating 25.0 hp 208 V normal duty 20.0 hp 208 V heavy duty 30.0 hp 230 V normal duty 25.0 hp 230 V heavy duty 60.0 hp 460 V normal duty 50.0 hp 460 V heavy duty 75.0 hp 575 V normal duty 60.0 hp 575 V heavy duty
Option card Communication module Profibus DP V1 Communication module Modbus TCP/EtherNet/IP Communication module CANopen daisy chain Communication module CANopen Sub-D Communication module CANopen open style
Complementary
Device connection In the motor supply line To the motor delta terminals
[Us] control circuit voltage 110...230 V AC 50/60 Hz - 15...10 %
Apparent power 0.09 kVA
Integrated motor overload protection True
motor thermal protection class Class 10E
Protection type Phase failure line Integrated thermal protection motor Thermal protection starter Current overload motor Underload motor Excessive starting time, locked rotor motor Motor phase loss motor Line supply phase loss line Line supply phase loss motor Thermal protection motor
current limiting %In (5 x Ie maximum) 150…700 %
[In] Rated current pwr loss specifctn 88.0 A
Power loss static current independent 25.0 W
Power loss per device current dependent 270.0 W
Standards IEC 60947-4-2 UL 60947-4-2 IEC 60664-1
Product Certifications CE cULus CCC UKCA RCM EAC DNV ABS BV CCS
Marking CE CCC UKCA EAC RCM CULus
[Uc] control circuit voltage 24 V DC
Discrete input number 4
Discrete input type STOP) logic inputs, 3500 Ohm RUN) logic inputs, 3500 Ohm DI3) programmable as logic input, 3500 Ohm DI4) programmable as logic input, 3500 Ohm
Input compatibility STOP discrete input level 1 PLC IEC 61131-2 RUN discrete input level 1 PLC IEC 61131-2 DI3 discrete input level 1 PLC IEC 61131-2 DI4 discrete input level 1 PLC IEC 61131-2
Discrete input logic Programmable digital input < 5 V
Relay output number 3
Relay output type Relay outputs R1A 1 NO Relay outputs R1B 1 NO Relay outputs RIC NO/NC programmable
Minimum switching current 100 mA 12 V DC relay outputs
Maximum switching current Relay outputs 2 A 250 V AC Relay outputs 2 A 30 V DC Relay outputs
Discrete output number 2
Discrete output type DQ1) programmable digital output <= 30 V DQ2) programmable digital output <= 30 V
Output compatibility Open collector level 1 PLC IEC 65A-68
Analogue input number 1
Analogue input type AI1/PTC PTC/Pt 100 temperature probe PTC2 PTC/Pt 100 temperature probe PTC3 PTC/Pt 100 temperature probe
Analogue output number 1
Analogue output type Current output AQ1 0...20 mA or 0...10 V 500 Ohm
Communication Port Protocol Modbus serial
Connector Type 1 RJ45
Communication data link Serial
Physical interface 2-wire RS 485
Transmission Rate 1200...256000 bit/s
Transmission frame RTU
Data format 8 bits, configurable odd, even or no parity
Type of polarization No impedance Modbus serial
Number of addresses 0…227 Modbus serial
Method of access Slave Modbus serial
Function Available External bypass control Pre-heating Smoke extraction Multi-motor cascade Second motor set User management Ports and services hardening Security event logging Cybersecure firmware update Single direction
Display screen available True
Operating position Vertical +/- 10 degree
Height 11.4 in (290.0 mm)
Width 7.5 in (190.0 mm)
Depth 9.7 in (247.0 mm)
Net Weight 18.3 lb(US) (8.3 kg)
Environment
Electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions with bypass level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-11 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5
pollution degree Level 3
[Uimp] rated impulse withstand voltage 6 kV
[Ui] Rated Insulation Voltage 690 V
Environmental class (during operation) Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3
Relative humidity 0…95 % without condensation or dripping water IEC 60068-2-3
Ambient air temperature for operation 104…140 °F (40…60 °C) (with current derating of 2 % per °C) 5…104 °F (-15…40 °C) (without derating)
Ambient Air Temperature for Storage -13…158 °F (-25…70 °C)
Operating altitude <= 3280.84 ft (1000 m) without derating > 3280.84...13123.36 ft (> 1000...4000 m) with current derating 1 % per 100 m
Maximum deflection under vibratory load (during operation) 1.5 mm at 2...13 Hz
Maximum deflection under vibratory load (during storage) 1.75 mm at 2...9 Hz
Maximum deflection under vibratory load (during transport) 1.75 mm at 2...9 Hz
Maximum acceleration under vibrational stress (during operation) 10 m/s² at 13...200 Hz
Maximum acceleration under vibratory load (during storage) 15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz
Maximum acceleration under vibratory load (during transport) 15 m/s² at 200...500 Hz 10 m/s² at 9...200 Hz
Maximum acceleration under shock impact (during operation) 150 m/s² at 11 ms
Maximum acceleration under shock load (during storage) 100 m/s² at 11 ms
Maximum acceleration under shock load (during transport) 100 m/s² at 11 ms
Ordering and shipping details
Category US1CP1G22588
Discount Schedule CP1G
GTIN 3606481089069
Returnability Yes
Country of origin FR
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 14.57 in (37.000 cm)
Package 1 Width 12.20 in (31.000 cm)
Package 1 Length 15.35 in (39.000 cm)
Package 1 Weight 21.572 lb(US) (9.785 kg)
Unit Type of Package 2 P06
Number of Units in Package 2 8
Package 2 Height 33.86 in (86.000 cm)
Package 2 Width 23.62 in (60.000 cm)
Package 2 Length 31.50 in (80.000 cm)
Package 2 Weight 190.700 lb(US) (86.500 kg)

Main documents

Main documents

Datasheet Download Datasheet
Product datasheet ATS480D88Y
User guide
Download
Instruction sheet
Download
Catalogue
Download
CAD Files Download
Environmental disclosure
Download

Main documents

Datasheet Download Datasheet
Product datasheet ATS480D88Y
User guide
Download
Instruction sheet
Download
Catalogue
Download
CAD Files Download
Environmental disclosure
Download

Reviews (0)

Be the first to review “Schneider ATS480D88Y | Soft starter, Altistart 480, 88A, 208 to 690V AC, control supply 110 to 230V AC”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare