Schneider LRE365 | Thermal overload relay,EasyPact TVS,80…104A,class 10A
Description
Schneider LRE365 | Thermal overload relay,EasyPact TVS,80…104A,class 10A
Schneider LRE365 | Thermal Overload Relay
The Schneider LRE365 is a thermal overload relay from the EasyPact TVS series, designed to provide efficient motor protection against overloads and phase failures. It is ideal for industrial and commercial applications requiring reliable motor safety.
1. General Specifications
-
Product Name: Schneider LRE365
-
Series: EasyPact TVS
-
Type: Thermal Overload Relay
-
Current Range: 80A to 104A
-
Trip Class: Class 10A
-
Mounting: Direct mounting on EasyPact TVS contactors
-
Reset Mode: Manual or Automatic
-
Phase Failure Protection: Yes
2. Key Features
Reliable Motor Protection – Prevents damage due to overloads and unbalanced phases.
Adjustable Current Setting – Supports a wide range (80-104A) for flexibility.
Direct Mounting on Contactors – Easy integration with EasyPact TVS contactors.
Automatic & Manual Reset Options – Allows customized operation.
Compact & Durable Design – Suitable for industrial environments.
3. Applications
🔹 Pumps
🔹 Fans & Blowers
🔹 Conveyors
🔹 Machine Tools
🔹 Compressors
4. Protection & Safety Features
Overload Protection – Prevents motor overheating.
Phase Failure Detection – Protects against motor damage.
Trip Indication – Allows easy troubleshooting.
5. Installation & Maintenance
-
Quick & Easy Installation with direct mounting on compatible contactors.
-
Low Maintenance due to its robust and reliable design.
-
Simple Adjustment Dial for setting current range.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Easy TeSys |
|---|---|
| Range of product | Easy TeSys Protect |
| Product or component type | Differential thermal overload relay |
| Device short name | LRE |
| Relay application | Motor protection |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 |
| Product compatibility | LC1E95 |
|---|---|
| Network type | AC |
| Network frequency | 50...60 Hz |
| Mounting support | Under contactor Plate, with specific accessories Rail, with specific accessories |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Signalling function | Relay trip indicator |
| Thermal protection adjustment range | 80…104 A |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Mechanical robustness | Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 3 GN conforming to IEC 60068-2-6 |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| [Ue] rated operational voltage | <= 690 V AC |
| Associated fuse rating | 80 A aM for power circuit 160 A gG for power circuit 5 A gG for signalling circuit |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Local signalling | Trip indicator |
| Control type | Push-button red stop: Push-button green reset: |
| Temperature compensation | -20…60 °C |
| Connections - terminals | Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end Power circuit: screw clamp terminals 1 4…35 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 4…35 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 4…35 mm² - cable stiffness: solid without cable end |
| Recommended tightening torque | Power circuit: 9 N.m - on screw clamp terminals Signalling circuit: 1.7 N.m - on screw clamp terminals |
| Height | 54 mm |
| Width | 70 mm |
| Depth | 113 mm |
| Net weight | 0.52 kg |
| Standards | IEC 60947-4-1 IEC 60947-5-1 |
|---|---|
| Product certifications | EAC |
| Protective treatment | TH conforming to IEC 60068 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 -20…70 °C with derating |
| Ambient air temperature for storage | -60…80 °C |
| Fire resistance | 850 °C conforming to IEC 60068-2-1 |
| Dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 |
| Electromagnetic compatibility | Surge withstand: 6 kV conforming to IEC 60801-5 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.500 cm |
| Package 1 Width | 9.000 cm |
| Package 1 Length | 12.500 cm |
| Package 1 Weight | 558.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 9 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.430 kg |
| Warranty | 18 months |
|---|