Description

Schneider LAEN22 | Auxiliary contact block, EasyPact TVS, 2NO+2NC

Schneider LAEN22 | Auxiliary Contact Block, EasyPact TVS, 2NO+2NC Description

In the realm of electrical components, the Schneider LAEN22 auxiliary contact block stands out as a crucial element. Paired with the advanced features of EasyPact TVS and its 2NO+2NC configuration, this combination offers a robust solution for various electrical applications.

Introduction to Schneider LAEN22

it is a high-quality auxiliary contact block designed to complement EasyPact TVS circuit breakers. It enhances the functionality of electrical installations by providing additional contact points for control circuits.

Overview of Auxiliary Contact Blocks

Auxiliary contact blocks like the LAEN22 are essential in electrical systems to signal the status of a circuit or to control additional functions. They act as extensions to primary contacts, offering versatility and expanded capabilities.

Understanding EasyPact TVS

EasyPact TVS is a range of reliable and efficient circuit breakers from Schneider Electric. Known for their performance and durability, EasyPact TVS breakers are widely used in industrial and commercial settings.

Description of 2NO+2NC Configuration

The 2NO+2NC configuration of EasyPact TVS refers to two normally open (NO) and two normally closed (NC) contacts. This configuration provides flexibility in electrical connections, allowing for diverse control options.

Benefits of Schneider LAEN22

  • Enhanced control: it enables precise control over electrical circuits.
  • Compatibility: Designed specifically for EasyPact TVS, ensuring seamless integration.
  • Versatility: Supports various applications due to its 2NO+2NC configuration.
  • Reliability: Schneider Electric’s reputation for quality ensures long-term reliability.

Installation Guide for Auxiliary Contact Blocks

Installing it auxiliary contact block is straightforward, requiring alignment with compatible EasyPact TVS breakers and secure mounting following manufacturer guidelines.

Maintenance Tips for EasyPact TVS

Regular inspection and maintenance of EasyPact TVS breakers and it contact blocks are crucial for optimal performance and safety. Follow recommended schedules and procedures provided by Schneider Electric.

Applications of 2NO+2NC Configuration

The 2NO+2NC configuration is beneficial in various scenarios such as motor control, lighting systems, and safety circuits. Its dual functionality allows for both control and monitoring tasks within electrical installations.

Importance of Electrical Safety

In any electrical system, safety is paramount. Utilizing high-quality components like Schneider LAEN22 and EasyPact TVS not only ensures operational efficiency but also reduces the risk of electrical hazards.

Conclusion

Schneider LAEN22, coupled with EasyPact TVS and its 2NO+2NC configuration, offers a reliable and efficient solution for modern electrical installations. Its versatility, compatibility, and safety features make it a preferred choice in industrial and commercial sectors.

FAQs on Schneider LAEN22

  1. What is the maximum current rating of it?
  2. Can it be used with other brands of circuit breakers?
  3. Are there any specific environmental conditions to consider during installation?
  4. How often should EasyPact TVS breakers and it contact blocks be inspected?
  5. Is there a warranty period for it and EasyPact TVS products?

Additional information

brands

Schneider Electric

Specifications

Main
Range Easy TeSys
range of product Easy TeSys Control
product or component type Auxiliary contact block
device application Signalling
Device short name LAEN
Colour Grey (RAL 7011)
Complementary
Range compatibility EasyPact EasyPact TVS LC1E
Mounting location Front
Auxiliary contacts operation Instantaneous
Pole contact composition 2 NO + 2 NC
[Ui] rated insulation voltage 690 V - for control circuit conforming to IEC 60947-5-1
[Ue] rated operational voltage <= 690 V
[Ith] conventional free air thermal current 8 A (at 60 °C)
Irms rated making capacity 140 A AC conforming to IEC 60947-5-1
[Icw] rated short-time withstand current 100 A - 1 s 120 A - 500 ms 140 A - 100 ms
Protection type GG fuse 10 A
Mechanical durability 10 Mcycles
Minimum switching current 5 mA
minimum switching voltage 17 V
Non-overlap time 1.5 ms on energisation no overlap between NC and NO contact 1.5 ms on de-energisation no overlap between NC and NO contact
Insulation resistance > 10 MOhm
Connections - terminals Control circuit: screw clamp terminals 1 1 mm² - external diameter: 6 mm - cable stiffness: solid or flexible with cable end Control circuit: screw clamp terminals 1 1 mm² - external diameter: 6 mm - cable stiffness: solid or flexible without cable end Control circuit: screw clamp terminals 2 2.5 mm² - external diameter: 6 mm - cable stiffness: solid or flexible with cable end Control circuit: screw clamp terminals 2 2.5 mm² - external diameter: 6 mm - cable stiffness: solid or flexible without cable end
net weight 0.06 kg
Environment
Environmental characteristic Standard environment
Standards IEC 60947-5-1
Product certifications GOST
IP degree of protection IP20 conforming to IEC 60529
Protective treatment TH conforming to IEC 60068
Ambient air temperature for operation -5…55 °C
Ambient air temperature for storage -60…80 °C
Operating altitude 3000 m without derating
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 3.800 cm
Package 1 Width 4.500 cm
Package 1 Length 5.000 cm
Package 1 Weight 61.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 72
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 4.729 kg
Contractual warranty
Warranty 18 months

Main Document

Main Document

Data Sheet : Download

Main Document

Data Sheet : Download

Reviews (0)

Be the first to review “Schneider LAEN22 | Auxiliary contact block, EasyPact TVS, 2NO+2NC”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Product was successfully added to your cart!

Select at least 2 products
to compare