Schneider LRE10 | Thermal overload relay,EasyPact TVS,4…6A,class 10A
Schneider LRE10 | Thermal overload relay,EasyPact TVS,4…6A,class 10A
Description
Schneider LRE10 | Thermal overload relay,EasyPact TVS,4…6A,class 10A
Schneider LRE10 | Thermal Overload Relay
The Schneider LRE10 is a thermal overload relay from the EasyPact TVS series, designed to provide efficient motor protection against overloads and phase failures. It ensures reliable performance in industrial applications, preventing motor damage and enhancing system safety.
1. General Specifications
-
Product Name: Schneider LRE10
-
Series: EasyPact TVS
-
Type: Thermal Overload Relay
-
Current Range: 4A to 6A
-
Trip Class: Class 10A
-
Mounting Type: Direct mounting on EasyPact TVS contactors
-
Reset Mode: Manual or Automatic
-
Phase Failure Protection: Yes
2. Key Features
Reliable Motor Overload Protection – Prevents excessive heating and damage.
Adjustable Current Range (4A-6A) – Provides flexible motor protection.
Seamless Integration with Contactors – Directly mounts on EasyPact TVS contactors.
Manual & Automatic Reset Options – Increases ease of use.
Compact & Durable Design – Suitable for industrial environments.
3. Applications
🔹 Pumps
🔹 Fans & Blowers
🔹 Conveyors
🔹 Machine Tools
🔹 Industrial Control Panels
4. Protection & Safety Features
Overload Protection – Prevents motor overheating.
Phase Failure Detection – Enhances motor safety and reduces downtime.
Trip Indicator – Facilitates quick troubleshooting.
5. Installation & Maintenance
-
Easy Installation with direct mounting on compatible contactors.
-
Low Maintenance with durable and high-quality components.
-
Adjustable Settings for optimal motor protection.
Additional information
| brands | Schneider Electric |
|---|
Specifications
| Range | Easy TeSys |
|---|---|
| Range of product | Easy TeSys Protect |
| Product or component type | Differential thermal overload relay |
| Device short name | LRE |
| Relay application | Motor protection |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 |
| Colour | Grey (RAL 7011) |
| Product compatibility | LC1E06...38 |
|---|---|
| Network type | AC |
| Network frequency | 50...60 Hz |
| Mounting support | Under contactor Plate, with specific accessories Rail, with specific accessories |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Signalling function | Relay trip indicator |
| Thermal protection adjustment range | 4…6 A |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Mechanical robustness | Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 3 GN conforming to IEC 60068-2-6 |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| [Ue] rated operational voltage | <= 690 V AC |
| Associated fuse rating | 16 A gG for power circuit 8 A aM for power circuit 5 A gG for signalling circuit |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Local signalling | Trip indicator |
| Control type | Push-button red stop: Push-button green reset: |
| Temperature compensation | -20…60 °C |
| Connections - terminals | Power circuit: screw clamp terminals 1 1.5…6 mm² - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 1…6 mm² - cable stiffness: solid without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end |
| Recommended tightening torque | Power circuit: 1.7 N.m - on screw clamp terminals Signalling circuit: 1.7 N.m - on screw clamp terminals |
| Height | 44.5 mm |
| Width | 45 mm |
| Depth | 70 mm |
| Net weight | 0.13 kg |
| Standards | IEC 60947-5-1 IEC 60947-4-1 |
|---|---|
| Product certifications | EAC |
| Protective treatment | TH conforming to IEC 60068 |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 -20…70 °C with derating |
| Ambient air temperature for storage | -60…80 °C |
| Fire resistance | 850 °C conforming to IEC 60068-2-1 |
| Dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 |
| Electromagnetic compatibility | Surge withstand: 6 kV conforming to IEC 60801-5 |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 5.500 cm |
| Package 1 Width | 8.200 cm |
| Package 1 Length | 8.700 cm |
| Package 1 Weight | 145.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 33 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 5.145 kg |
| Warranty | 18 months |
|---|