Schneider A9D11810 | iC60H – earth leakage circuit breaker – 1P + N – C curve – 10 A – 30 mA – 240 V
Description
Schneider A9D11810 | Acti9 iC60 with overcurrent protection (RCBO). 1P+N circuit breaker with 1 protected pole, 10A
Product Overview: Schneider A9D11810 | iC60H RCBO – 1P+N – 10A – C Curve – 30mA – 240V
The Schneider Electric A9D11810 is a high-performance earth leakage circuit breaker from the Acti9 iC60H range. It features 1P+N (single pole + neutral) configuration, a C curve tripping characteristic, a rated current of 10A, and a residual current sensitivity of 30 mA. Designed for 240V AC applications, this RCBO provides both overcurrent protection and earth leakage protection, making it ideal for residential and commercial electrical safety.
Key Features:
-
Brand: Schneider Electric
-
Series: Acti9 iC60H
-
Model Number: A9D11810
-
Product Type: RCBO (Residual Current Breaker with Overcurrent)
-
Poles: 1P + N (Single Pole + Neutral)
-
Tripping Curve: C Curve
-
Rated Current: 10A
-
Residual Current Sensitivity: 30 mA
-
Rated Voltage: 240V AC
Technical Specifications:
-
Breaking Capacity: High-performance short-circuit protection
-
Sensitivity: 30 mA (for personal protection against electric shocks)
-
Tripping Curve: Type C (ideal for general-purpose loads with moderate inrush current)
-
Frequency: 50/60 Hz
-
Mounting: DIN rail
-
Standards Compliance: IEC 61009-1
Functional Features:
-
Dual Protection:
– Provides protection against earth leakage and overcurrent (short circuit and overload) -
Compact Design:
– Saves space in distribution boards -
Visual Indicators:
– Clear ON/OFF and fault indication -
High Reliability:
– Long electrical and mechanical lifespan -
Resettable:
– Can be manually reset after a fault occurs
Applications:
-
Residential homes
-
Commercial buildings
-
Small office environments
-
Protection of socket outlets, lighting, and appliances
-
Areas with risk of direct contact or moisture
Benefits:
-
Enhanced Safety:
– Detects even small leakage currents (30 mA) to protect human life -
Quick Response:
– Rapid disconnection in the event of a fault -
Ease of Use:
– Simple installation and reset mechanism -
Space Efficiency:
– 1 module width per pole -
Compliance & Trust:
– Backed by Schneider’s global quality standards
Typical Users:
-
Electricians and installers
-
Residential developers
-
Electrical maintenance teams
-
Building contractors
-
Facility managers
Additional information
| brands | Schneider Electric |
|---|
Specifications
| circuit breaker application | Distribution |
|---|---|
| Range | Acti9 |
| Product name | Acti9 iC60 RCBO |
| Product or component type | Residual current breaker with overcurrent protection (RCBO) |
| Device short name | iC60H RCBO |
| Poles description | 1P + Ns |
| [In] rated current | 10 A at 50 °C |
| Earthing system | TN |
| Curve code | C |
| Earth-leakage sensitivity | 30 mA |
| Breaking capacity | 10000 A Icn at 230/240 V AC 50/60 Hz |
| Neutral position | Left |
|---|---|
| Number of protected poles | 1 |
| device location in system | Outgoer |
| Network frequency | 50 Hz |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| [Ue] rated operational voltage | 230/240 V AC 50/60 Hz |
| Residual current tripping technology | Voltage dependent |
| earth-leakage protection time delay | Instantaneous |
| Earth-leakage protection class | Type A |
| [Icw] rated short-time withstand current | Icw: 250 A during 8/20 µs impulse withstand |
| [Ics] rated service breaking capacity | 7500 A at 230/240 V AC 50/60 Hz |
| Limitation class | 3 |
| [Ui] rated insulation voltage | 400 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Surge current | 250 A |
| Suitability for isolation | Yes |
| Contact position indicator | Yes |
| control type | Toggle |
| local signalling | ON/OFF indication |
| Mounting mode | Clip-on |
| mounting support | DIN rail |
| Comb busbar and distribution block compatibility | NO |
| 9 mm pitches | 2 |
| height | 110 mm |
| Width | 18 mm |
| Depth | 77.5 mm |
| Net weight | 205 g |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 5000 cycles |
| Provision for padlocking | Padlockable with padlock Ø 4 mm |
| Locking options description | ON/OFF locking facilities |
| Connections - terminals | Screw clamp terminal (top) 1…25 mm² rigid without cable end Screw clamp terminal (top) 1…16 mm² flexible Screw clamp terminal (bottom) 1…16 mm² rigid without cable end Screw clamp terminal (bottom) 1…10 mm² flexible |
| Wire stripping length | Power circuit: 13 mm for bottom connection Power circuit: 14 mm for top connection |
| Tightening torque | Power circuit: 3.5 N.m top Power circuit: 2 N.m bottom |
| earth-leakage protection | Integrated |
| Standards | BS EN 61009-1 IEC 61009-1 IEC 61009-2-2 AS/NZS 61009.1 |
|---|---|
| IP degree of protection | IP20 |
| Tropicalisation | 2 |
| Relative humidity | 95 % at 55 °C |
| ambient air temperature for operation | -15…60 °C |
| Ambient air temperature for storage | -40…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 2.5 cm |
| Package 1 Width | 11.2 cm |
| Package 1 Length | 13.8 cm |
| Package 1 Weight | 216 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 34 |
| Package 2 Height | 15 cm |
| Package 2 Width | 30 cm |
| Package 2 Length | 40 cm |
| Package 2 Weight | 7.662 kg |
| Unit Type of Package 3 | P12 |
| Number of Units in Package 3 | 1088 |
| Package 3 Height | 77 cm |
| Package 3 Width | 80 cm |
| Package 3 Length | 120 cm |
| Package 3 Weight | 261.568 kg |
Main Document
Main Document
Data Sheet : A9D11810
Main Document
Data Sheet : A9D11810
Reviews (0)